11 Technical Data
Fieldgate FXA520
98
Hauser
11 Technical Data
Table 11-1 provides you with the most important technical data - the full technical data is to be
found in Technical Information TI025S/04/en.
Table 11-1: Overview Technical Data
Property
Attribute
Supply voltage:
AC version: 85...253 VAC, 50/60 Hz
DC version: 20...60 VDC or 20...30 VAC
Typical current consumption:
AC version: 4.9 VA ton 8 VA, depending upon version
DC version: 1.5 W to 4 W, depending upon version
Dimensions (W x H x D):
45 mm x 108 mm x 112 mm (1.8" x 4.25" x 4.4")
Mounting:
TS35 DIN carrier rail (EN 50022)
Weight (approx.):
approx. 0.25 kg (approx 9 oz)
Protection class:
II
Degree of protection:
IP 20
Ambient temperature during
operation:
Individual mounting: -20°C... +60°C (-4°F...+140°F)
Row mounting: -20°C... +50°C (-4°F...+122°F)
Protective housing: -20°C... +40°C (-4°F...+104°F)
Ambient temperature for storage:
-25°C... +85°C, preferably at +20°C (-13°F...+185°F, preferably at 68°F)
Climatic and mechnical application
class:
3K3, in accordance with DIN EN 60721-3-3
3M2, in accordance with DIN EN 60721-3-3