Operation
EngyVolt RV12
16
Key
View No. Description
3-phase, 4-wire
View No. Description
3-phase, 3-wire
View No. Single-phase, 2-wire
A0016377
1
A L1 (current L1)
A L2 (current L2)
A L3 (current L3)
1
A L1 (current L1)
A L2 (current L2)
A L3 (current L3)
1
A L1 (current L1)
2
A neutral current
3
A L1 MAX
(Current L1, maximum value,
time-integrated, maximum
indicator function)
A L2 MAX
(Current L2, maximum value,
time-integrated, maximum
indicator function)
A L3 MAX
(Current L3, maximum value,
time-integrated, maximum
indicator function)
2
A L1 MAX
(Current L1, maximum value,
time-integrated, maximum
indicator function)
A L2 MAX
(Current L2, maximum value,
time-integrated, maximum
indicator function)
A L3 MAX
(Current L3, maximum value,
time-integrated, maximum
indicator function)
2
A L1 MAX
(Current L1, maximum value,
time-integrated, maximum
indicator function)
4
A neutral current MAX
(Maximum value, time-
integrated, maximum indicator
function)
5
I %THD* L1
(%THD current L1)
I %THD* L2
(%THD current L2)
I %THD* L3
(%THD current L3)
3
I %THD* L1
(%THD current L1)
I %THD* L2
(%THD current L2)
I %THD* L3
(%THD current L3)
3
I %THD* L1
(%THD current L1)
A0016379
1
kW active power
kvar reactive power
kVA apparent power
1
kW active power
kvar reactive power
kVA apparent power
1
kW active power
kvar reactive power
kVA apparent power
2
kW MAX (active power,
maximum value, time-
integrated, maximum indicator
function)
2
kW MAX (active power,
maximum value, time-
integrated, maximum indicator
function)
2
kW MAX (active power,
maximum value, time-
integrated, maximum indicator
function)
3
PF power factor (with symbol:
coil = inductive, capacitor =
capacitance)
3
PF power factor (with symbol:
coil = inductive, capacitor =
capacitance)
3
PF power factor (with symbol:
coil = inductive, capacitor =
capacitance)
A0016378
1
kWh imported electrical energy
(active component)
1
kWh imported electrical energy
(active component)
1
kWh imported electrical energy
(active component)
2
kWh exported electrical energy
(active component)
2
kWh exported electrical energy
(active component)
2
kWh exported electrical energy
(active component)
3
kvarh imported electrical energy
(reactive component)
3
kvarh imported electrical energy
(reactive component)
3
kvarh imported electrical energy
(reactive component)
4
kvarh exported electrical energy
(reactive component)
4
kvarh exported electrical energy
(reactive component)
4
kvarh exported electrical energy
(reactive component)
*) %THD = % Total Harmonic Distortion
5.4
Configuration mode
The abbreviation for the parameter is displayed in the top display row in the configuration
mode. The middle row displays the parameter value. The bottom row is used to confirm
the set value of the parameter.
To enter the configuration mode, press and hold the and keys simultaneously for 5
seconds. The screen to enter the 4-digit password is displayed. No default password is set.
A password can be used to prevent unauthorized access to the device settings. Once the
correct password has been entered, the device is on the first level of the menu structure. If