Deltapilot S
44
Hauser
DB53 – cable version with
suspension clamp
→
For continuation of ordering information for DB53, see the following page.
10
Approval:
A
Version for non-hazardous area
G
ATEX II 1/2 G
EEx ia IIC T6
H
ATEX II 2 G
EEx ia IIC T6
N
ATEX II 3 G
EEx nA II T6
S
CSA
IS, Class I, Division 1, Groups A – D
T
CSA
IS, Class I, Division 2, Groups A – D
20
Probe:
K
… mm FEP extension cable (probe length: 0.5 to 200 m)
M
… mm PE extension cable (probe length: 0.5 to 200 m)
L
… mm FEP extension cable for EEx ia, CSA IS (probe length: 0.5 to 100 m)
N
… mm PE extension cable for EEx ia, CSA IS (probe length: 0.5 to 100 m)
30
Process connection:
70
Cable probe without suspension clamp
71
Suspension clamp AISI 316L
40
Measuring range:
BA
0 to 100 mbar/1 mH
2
O/40 inH
2
O
BB
0 to 400 mbar/4 mH
2
O/160 inH
2
O
BC
0 to 1200 mbar/12 mH
2
O/480 inH
2
O
BD
0 to 4000 mbar/40 mH
2
O/1600 inH
2
O
BE
0 to 10 bar/100 mH
2
O/4000 inH
2
O
50
Linearity; Fill fluid:
1
< 0.2 % of measuring range; FDA compliant
2
< 0.2 % of measuring range; inert oil
3
< 0.1 % of measuring range; FDA compliant
4
< 0.1 % of measuring range; inert oil
Z
Additional specification
60
Measuring sensor seal:
1
Viton
2
EPDM
5
Kalrez
3
Sensor welded
70
Electronics; Output:
Electronic inserts without integrated overvoltage protection
A
Without integrated electronic insert (e.g. for ordering spare parts)
B
FEB11, 3-wire analog signal
C
FEB17, 2-wire PFM signal
E
FEB22, 4 to 20 mA, HART
G
FEB22, 4 to 20 mA, HART, with FHB20 onsite display
H
FEB24, PROFIBUS PA
K
FEB24, PROFIBUS PA, with FHB20 onsite display
1
FEB26, FOUNDATION Fieldbus
2
FEB26, FOUNDATION Fieldbus, with FHB20 onsite display
Electronic inserts with integrated overvoltage protection
M
FEB11P, 3-wire analog signal
N
FEB17P, 2-wire PFM signal
R
FEB22P, 4 to 20 mA, HART
T
FEB22P, 4 to 20 mA, HART, with FHB20 onsite display
U
FEB24P, PROFIBUS PA
W
FEB24P, PROFIBUS PA, with FHB20 onsite display
DB53