Deltapilot S
4
Hauser
Function and system design
Device selection
Deltapilot S –
product family
DB50/DB50A
P01-DB5xxxxx-14-xx-xx-xx-001
Compact version
DB50L/DB50S
P01-DB5xxxxx-14-xx-xx-xx-002
Compact version as
hygienic version
DB51/DB51A
P01-DB5xxxxx-14-xx-xx-xx-003
Rod version
DB52/DB52A
P01-DB5xxxxx-14-xx-xx-xx-004
Cable version
DB53/DB53A
P01-DB5xxxxx-14-xx-xx-xx-005
Cable version with
suspension clamp
Field of application
– Level measurement
– Differential pressure measurement (derived from level via switching unit)
Industries
Food, pharmaceutical, environment (fresh water and wastewater), chemical
Process connections
– Thread
– Flanges
– Flush-mounted
hygienic connections
– Thread
– Flanges
– Thread
– Flanges
– Suspension clamp
Process connection
material
– AISI 316L
– Alloy C4
– AISI 316L
– AISI 316L
– Alloy C4
– AISI 316L
– Alloy C4
– AISI 316L with
plastic
Rod (pipe)/
extension cable material
—
—
– AISI 316L
– Alloy C4
– FEP
– PE
– FEP
– PE
Pipe/extension cable
length
—
—
400 to 4000 mm
(16 to 160 inch)
0.5 to 200 m
(20 to 7874 inch)
1
0.5 to 200 m
(20 to 7874 inch)
1
Measuring ranges
– from –100 to +100 mbar to –900 to +10000 mbar
– US version: from –1.5 to +1.5 psi to –13 to 150 psi
– Max. turn down: 10:1
Process temperature
–10 to +100°C
(+14 to +212°F)
–10 to +100°C
(+14 to +212°F),
+135°C (+275°F)
for 30 minutes
–10 to +80°C
(+14 to +176°F)
–10 to +80°C
(+14 to +176°F)
–10 to +80°C
(+14 to 176°F)
Supply voltage
– Analog 0.2 to 1.2 mA: 15 to 20 V DC
– PFM: 14 to 16 V DC; EEx ia: 14 to 19.2 V DC
– 4 to 20 mA HART: 11.5 to 30 V DC; EEx ia: 11.5 to 30 V DC
– PROFIBUS PA , version without overvoltage protection: 9 to 32 V DC, EEx ia: 9 to 24 V DC
Version with overvoltage protection: 9.6 to 32 V DC; EEx ia: 9 to 24 V DC
– FOUNDATION Fieldbus: 9 to 32 V DC; EEx ia: 9 to 24 V DC
Output
0.2 to 1.2 mA, analog, PFM, 4 to 20 mA with superimposed HART protocol, PROFIBUS PA or FOUNDATION Fieldbus
Options
– 3.1 Inspection
certificate
– Separate housing
– 3.1 Inspection
certificate
– Separate housing
– Separate housing
– Separate housing
—
Specialties
– Absolutely resistant to condensate thanks to hermetically sealed CONTITE
TM
cell
– Stainless steel version (AISI 316L) for hygienic requirements as well as aluminum and polyester housing versions
– 3A and EHEDG approval
– Maximum flexibility thanks to modular design
1)
EExia, FM IS, CSA IS: 0.5 to 100 m (20 to 3937 inch)