background image

BA 135C.00/14/f-e/08.95

dipsys

CLA 111
Sonde à immersion pour 
la mesure de conductivité

Instrumentation analyse

Instructions de montage et 
de mise en service

Содержание CLA 111

Страница 1: ...BA 135C 00 14 f e 08 95 dipsys CLA 111 Sonde immersion pour la mesure de conductivit Instrumentation analyse Instructions de montage et de mise en service...

Страница 2: ...u des l ments de montage Overview of mounting parts 6 3 2 Dimensions Dimensions 9 3 3 Montage Installation 10 3 3 1 Montage de la cellule de mesure Measuring cell installation 10 3 3 2 Raccordement d...

Страница 3: ...t e avec des ac cessoires comme le gicleur ou le m t de fixa tion 1 General 1 1 Unpacking Inspect for any damaged packaging The post office or freight carrier must be informed of any damage Damaged p...

Страница 4: ...iable de la profondeur d immersion Y Montage sp cial sur demande CLA 111 r f rence compl te 1 3 Order code Immersion assembly Dipsys CLA 111 Length of assembly 0 1000 mm 1 2000 mm 2 Special length 500...

Страница 5: ...ons relatives aux r servoirs sous pression 1 4 Safety notes Caution The notes and warnings in these installation and operating instructions must be strictly adhered to Faults in the assembly may only...

Страница 6: ...l Longueur de r serve pour montage Excess cable length for installation C ble de mesure par ex KMK DMK Measuring cable e g KMK DMK C ble de raccordement de la cellule avec connecteur joint avec la cel...

Страница 7: ...ube de liaison diam tre externe 10 mm mat riau PP avec raccord pour nettoyage avec Chemoclean 12 Raccord Gardena pour nettoyage avec Chemoclean Fig 3 1 Overview Dipsys CLA 111 1 Recessed head srews 4...

Страница 8: ...Insert assembly in installed DN 100 flange Screw in assembly by turning assembly head clockwise until limit position Endlage 2 is reached Disassembly of Dipsys CLA 111 Leave installed DN 100 flange on...

Страница 9: ...of Dipsys CLA 111 mounting version Y can be immersed using assembly holder CYH 101 The assembly length is fixed to 1 m Different immersion depths can be obtained by adjusting the mounting chain Weight...

Страница 10: ...ell CLS 21 7 Chemoclean spray head CLR 30 8 Measuring cell CLS 40 9 Through hole for captive star handle screws Fig 3 5 Dipsys CLA 111 gauche Version de montage A 1 T te de sonde 2 PE 13 5 3 Vis crois...

Страница 11: ...holder 2 counterclockwise Measuring cell Installation CLS 21 Push O ring over threaded shaft CLS 21 Screw measuring cell into measuring cell holder from above CLS 40 Pull measuring cable in measuring...

Страница 12: ...according to fig 3 8 A leave excess measuring cable length approx 10 cm Engage bayonet lock by turning measuring cell holder 6 clockwise Push KMK measuring cable through Pg 13 5 hole 7 and connect acc...

Страница 13: ...utre longueur 500 3000 mm Section de montage n cessaire DN 100 Poids env 4 kg Mounting Version A DN 100 flange with additional captive star handle screws Version B DN 100 adjustable flange Materials i...

Страница 14: ...arts of the electrode being in contact with the medium and note the following please Remove light coatings and soiling using a suitable cleaning solution Use a soft brush and appropriate cleaning solu...

Страница 15: ...C 1E 4A CLS 40 C 1C 4A Spray head Chemoclean CLR 30 for measuring cell CLS 21 for automatic chemical cleaning of measuring cells in mounted condition Mounting frame for convenient installation on bas...