Once the pool is full and all connections are made, the water qual-
ity system can be started. Verify that the Nature 2 cartridge is in-
stalled inside the skimmer-filter cartridge.
When power is first introduced to the system, the heater-control-
ler will go through a boot-up cycle (which can last 2-5 minutes).
During this boot-up cycle it is important that no buttons on the
keypad are pushed. At the end of the boot up cycle the keypad
should display the temperature of the water.
If the keypad is flashing, “FLO” then air may need to be bled out of
the system. Turn the power off and slowly unthread one of the pump
unions, allowing any air to escape the system. When bleeding the
system you will lose some water so it is important to take this into
account. Once the air has been bled out, retighten the union.
After the system is turned on and the heater-controller has verified
proper water flow (to avoid heater activation in dry conditions),
the heater will automatically turn on to reach and maintain the
water temperature set point.
Your heater-controller has been programmed to run your circulat-
ing pump continuously, meaning that your pool is receiving au-
tomated circulation and filtration (through the skimmer/filter) 24
hours a day. The temperature of your pool is controlled by the up
and down keys on your keypad (Refer to the following section for
more information on the heater-controller features).
The Heater-Controller has a freeze protection feature called Smart
Winter Mode. Smart Winder Mode senses the ambient tempera-
ture around the heater-controller and turns on the optional hydro-
therapy jet pump as the temperature drops. The colder the tem-
perature, the more frequently the pump will turn on.
The Smart Winter Mode indicator light (see Keypad Function sec-
tion) is illuminated when this feature is activated.
The heater-controller also is programmed to turn the optional hy-
drotherapy jet pump on 4 times daily, for 60 seconds.
Heater-Controller
The in.xe is a heater controller used by Endless Pools to control
the following water quality features:
• Water temperature can be set between 59ºF and 92ºF (15ºC -
33ºC). Default set point at 84ºF (29ºC). The set point is changed
with the up and down keys.
• The Circulating Pump, CP, is always on. The heater can only turn
on when CP is on.
• Pressing the light key will turn lights on/off with an on time of
120 minutes.
• Optional Pump #1 is for a single speed Jet pump. Pressing the
first key turns pump 1 on/off, with a run time of 30-minutes. The
heating element is turned off when Pump #1 is activated. To aid
in filtration there are 4-purges per day.
• Optional UV is always on except when the circulation pump is
turned off.
• Holding first key for 5-seconds will turn off all devices for 30
minutes to allow for servicing. Pressing again will return to nor-
mal operation.
(in.xe) UL/CSA electrical specifications:
Input rating: 120/240 VAC
(2-phase required, with neutral) 48 A maximum, 60Hz. Software
limited to 24A. Install on a 30A GFCI circuit.
UL/CSA Standards:
UL 1563 Fifth Ed.
File: E182156
CSA No. 22.2 - 218.1-M89.
TUV Standards:
EN/IEC 60335 - 2 - 60
EN55014-1
EN55014-2
EN61000-3-2
EN61000-3-3
Circulating Pump
The circulating pump has been provided with an integral dry
run protection thermostat feature, that turns the pump off when
the pump runs dry (thermostat off at 212ºF + 10ºF [100ºC -
5ºC]). If left unattended, the thermostat will automatically reset
within a relatively short amount of time when the unit cools
down, thereby allowing the pump to again begin operation (at
176ºF + 13ºF [80ºC - 9ºC]). Depending on the system condi-
tions, many times one or two of these off/on cycles will correct
an air bound dry run condition by itself with no harm done to
the pump, thereby allowing continued trouble free operation.
However, if the off/on cycling persists then measures should be
taken to correct the problems in the circulation system causing
the on/off cycling.
Floating Thermal Cover
Endless Pools, Inc. provides a lightweight cover for the Endless
Pool, if a retractable security cover has not been purchased. This
cover floats on the water surface, insulating the pool while pre-
venting evaporation. Consistent use of this cover will keep the
water cleaner, save energy, and help control humidity. The cover
should be completely removed from the water before the machine
is used. With standard width Endless Pools (7’ [2,13m] inside di-
mension) the cover is shipped in a box with clips along with a
1-1/4” (3,8cm) PVC pipe. Replacement covers are available from
our Customer Service Department. The cover, once cut to size and
installed on the PVC pipe, rolls out onto the water surface.