background image

Once the pool is full and all connections are made, the water qual-

ity system can be started. Verify that the Nature 2 cartridge is in-

stalled inside the skimmer-filter cartridge. 

When power is first introduced to the system, the heater-control-

ler will go through a boot-up cycle (which can last 2-5 minutes). 

During this boot-up cycle it is important that no buttons on the 

keypad are pushed. At the end of the boot up cycle the keypad 

should display the temperature of the water.
If the keypad is flashing, “FLO” then air may need to be bled out of 

the system. Turn the power off and slowly unthread one of the pump 

unions, allowing any air to escape the system.  When bleeding the 

system you will lose some water so it is important to take this into 

account. Once the air has been bled out, retighten the union. 

After the system is turned on and the heater-controller has verified 

proper water flow (to avoid heater activation in dry conditions), 

the heater will automatically turn on to reach and maintain the 

water temperature set point.

Your heater-controller has been programmed to run your circulat-

ing pump continuously, meaning that your pool is receiving au-

tomated circulation and filtration (through the skimmer/filter) 24 

hours a day. The temperature of your pool is controlled by the up 

and down keys on your keypad (Refer to the following section for 

more information on the heater-controller features).

The Heater-Controller has a freeze protection feature called Smart 

Winter Mode. Smart Winder Mode senses the ambient tempera-

ture around the heater-controller and turns on the optional hydro-

therapy jet pump as the temperature drops.  The colder the tem-

perature, the more frequently the pump will turn on.

The Smart Winter Mode indicator light (see Keypad Function sec-

tion) is illuminated when this feature is activated.

The heater-controller also is programmed to turn the optional hy-

drotherapy jet pump on 4 times daily, for 60 seconds.

Heater-Controller

The in.xe is a heater controller used by Endless Pools to control 

the following water quality features:

•  Water  temperature  can  be  set  between  59ºF  and  92ºF  (15ºC  - 

33ºC). Default set point at 84ºF (29ºC). The set point is changed 

with the up and down keys.

•  The Circulating Pump, CP, is always on. The heater can only turn 

on when CP is on.

•  Pressing the light key will turn lights on/off with an on time of 

120 minutes.

•  Optional Pump #1 is for a single speed Jet pump. Pressing the 

first key turns pump 1 on/off, with a run time of 30-minutes. The 

heating element is turned off when Pump #1 is activated. To aid 

in filtration there are 4-purges per day.

•  Optional UV is always on except when the circulation pump is 

turned off. 

•  Holding first key for 5-seconds will turn off all devices for 30 

minutes to allow for servicing. Pressing again will return to nor-

mal operation.

 (in.xe) UL/CSA electrical specifications: 

Input rating: 120/240 VAC

(2-phase required, with neutral) 48 A maximum, 60Hz. Software 

limited to 24A. Install on a 30A GFCI circuit.

UL/CSA Standards:

 UL 1563 Fifth Ed.

File: E182156
CSA No. 22.2 - 218.1-M89.

TUV Standards:

EN/IEC 60335 - 2 - 60
EN55014-1
EN55014-2
EN61000-3-2
EN61000-3-3

Circulating Pump

The circulating pump has been provided with an integral dry 

run protection thermostat feature, that turns the pump off when 

the  pump  runs  dry  (thermostat  off  at  212ºF  +  10ºF  [100ºC  - 

5ºC]). If left unattended, the thermostat will automatically reset 

within a relatively short amount of time when the unit cools 

down, thereby allowing the pump to again begin operation (at 

176ºF + 13ºF [80ºC - 9ºC]). Depending on the system condi-

tions, many times one or two of these off/on cycles will correct 

an air bound dry run condition by itself with no harm done to 

the pump, thereby allowing continued trouble free operation. 

However, if the off/on cycling persists then measures should be 

taken to correct the problems in the circulation system causing 

the on/off cycling.

Floating Thermal Cover

Endless Pools, Inc. provides a lightweight cover for the Endless 

Pool, if a retractable security cover has not been purchased. This 

cover floats on the water surface, insulating the pool while pre-

venting evaporation. Consistent use of this cover will keep the 

water cleaner, save energy, and help control humidity. The cover 

should be completely removed from the water before the machine 

is used. With standard width Endless Pools (7’ [2,13m] inside di-

mension) the cover is shipped in a box with clips along with a 

1-1/4” (3,8cm) PVC pipe. Replacement covers are available from 

our Customer Service Department. The cover, once cut to size and 

installed on the PVC pipe, rolls out onto the water surface.

9

Содержание 2001779

Страница 1: ...WATER QUALITY SYSTEM USER S GUIDE Original Endless Pool with 4 Button Keypad...

Страница 2: ...rning standard is dependent on the installation method and the requirements and definitions used by the local gov erning bodies All electrical connections should be made by a licensed electrician in a...

Страница 3: ...2...

Страница 4: ...circuit conductors supplying this equipment The electrical components inside the spa cabinet will have means to connect the local common bond ing grid Connect these components to the bonding grid usin...

Страница 5: ...are sized to match the flow rate Always use compatible suction fittings should they need to be replaced NEVER replace a suction fitting with one rated less than the flow rate marked on the original s...

Страница 6: ...splay shows the desired temperature NOT the current water temperature Off Mode This mode allows you to stop all outputs for 30 minutes to perform a quick spa maintenance Press and hold Key 1 key for 5...

Страница 7: ...chemical will be purchased at any local pool and spa retail center Household bleach in its most basic form is the most appropriate form of chlorine for an indoor Endless Pool that is covered when not...

Страница 8: ...r and Indoor Pools Many customers are sold a stabilized chlorine product for use in their indoor Endless Pool Endless Pools would not recommend this practice as Clorox bleach is ideal for this setting...

Страница 9: ...he submerged hydraulic motor and the pool equipment If the level is too high damage can occur to the liner and it can make the water prone to scaling when minerals and metals dissolved in the water wi...

Страница 10: ...keys The Circulating Pump CP is always on The heater can only turn on when CP is on Pressing the light key will turn lights on off with an on time of 120 minutes Optional Pump 1 is for a single speed...

Страница 11: ...at the bottom of the filter car tridge making sure the handle is facing towards the opening Fig 50 The retention strap should prevent the Nature 2 cartridge from falling out of the filter cartridge R...

Страница 12: ...y four months it is best to coordinate this around the cleaning of your filter cartridges see Every two months above New Nature 2 cartridges can be purchased on our customer website www myendlespool c...

Страница 13: ...problem special consideration must be taken to protect the pool and ancillary equipment if either is located outside If you have any questions regarding precautions to take against freezing please cal...

Страница 14: ...s not plugged in 5 Plug pump in Plug must lock into place 6 Swim current turned on 6 Condition is normal 7 Circulating pump turned off at keypad 7 Turn pump back on by pressing key 1 on keypad or wait...

Страница 15: ...14 TEST LOG...

Страница 16: ...Endless Pools 1601 Dutton Mill Rd Aston PA 19014 2931 800 910 2714 US 610 497 8693 fax www myendlesspool com 2008 VGB Complient D490071_en 0119 2019 Endless Pools...

Отзывы: