8. Water Quality System Troubleshooting 

Symptom 

Possible Cause 

Solution

No power to controller

 

1.) Tripped breaker 

1.) Reset breaker

 

2.) Disconnect turned off 

2.) Turn disconnect to ON position

 

3.) Improperly wired controller 

3.) Verify wiring of controller 

No Keypad Display

 

1.) No power to controller 

1.) See above diagnosis

 

2.) Keypad cord not attached 

2.)  Plug in keypad cord. Plug must  

“lock” into place.

 

3.) Pins in display receptacle are bent 

3.)  Straighten pins to allow cord to  

properly attach

 

4.) 1/2 amp fuse blown in heater controller 

4.)  Check for continuity on fuse and  

replace if necessary

FLO Reading on Display

 

1.) Pump housing not filled with water 

1.) Remove air from housing  

 

       (prime pump)

 

2.) Water level too low 

2.)  Add water to pool

 

3.) Filter is dirty 

3.) Clean filter(s)

 

4.) Ball valve is closed or return  

4.)  Open valve or remove plug 

line is plugged

 

5.) Circulating pump is not plugged in 

5.)  Plug pump in. Plug must “lock”  

into place

 

6.) Swim current turned on 

6.) Condition is normal

 

7.) Circulating pump turned off at keypad 

7.)  Turn pump back on by pressing key 1 on 

keypad or wait 30 minutes for auto restart of 

circulating pump

 

8.) No power to pump receptacle on  

8.)  20 amp fuse may be blown inside heater con-

troller heater controller. If fuse not blown, turn 

off breaker for 5 minutes and reset. If still no 

voltage to receptacle replace heater controller    

Circulating Pump Makes Noise

     1.) Debris in impeller 

1.)  Remove pump from system, take apart pump   

and clean ceramic ball that the impeller sits on

 

2.) Air trapped in housing 

2.)  Remove air from housing (prime pump)

 

3.) Rotor bearing worn 

3.) Replace pump 

 

 

 

  

  

Pool taking long time to heat

 

1.) Heater not turning on 

1.)  Controller not calling for heat-check 

 thermostat set point

 

2.) Heat indicator on, no heat gain 

2.)  Check element continuity (14ohms). Replace if 

not in this range

 

3.) Losing heat from pool 

3.)  Insulate pool. Keep pool covered when not 

in use. Refer to “Retaining Heat” Service 

Instruction 

13

Содержание 2001779

Страница 1: ...WATER QUALITY SYSTEM USER S GUIDE Original Endless Pool with 4 Button Keypad...

Страница 2: ...rning standard is dependent on the installation method and the requirements and definitions used by the local gov erning bodies All electrical connections should be made by a licensed electrician in a...

Страница 3: ...2...

Страница 4: ...circuit conductors supplying this equipment The electrical components inside the spa cabinet will have means to connect the local common bond ing grid Connect these components to the bonding grid usin...

Страница 5: ...are sized to match the flow rate Always use compatible suction fittings should they need to be replaced NEVER replace a suction fitting with one rated less than the flow rate marked on the original s...

Страница 6: ...splay shows the desired temperature NOT the current water temperature Off Mode This mode allows you to stop all outputs for 30 minutes to perform a quick spa maintenance Press and hold Key 1 key for 5...

Страница 7: ...chemical will be purchased at any local pool and spa retail center Household bleach in its most basic form is the most appropriate form of chlorine for an indoor Endless Pool that is covered when not...

Страница 8: ...r and Indoor Pools Many customers are sold a stabilized chlorine product for use in their indoor Endless Pool Endless Pools would not recommend this practice as Clorox bleach is ideal for this setting...

Страница 9: ...he submerged hydraulic motor and the pool equipment If the level is too high damage can occur to the liner and it can make the water prone to scaling when minerals and metals dissolved in the water wi...

Страница 10: ...keys The Circulating Pump CP is always on The heater can only turn on when CP is on Pressing the light key will turn lights on off with an on time of 120 minutes Optional Pump 1 is for a single speed...

Страница 11: ...at the bottom of the filter car tridge making sure the handle is facing towards the opening Fig 50 The retention strap should prevent the Nature 2 cartridge from falling out of the filter cartridge R...

Страница 12: ...y four months it is best to coordinate this around the cleaning of your filter cartridges see Every two months above New Nature 2 cartridges can be purchased on our customer website www myendlespool c...

Страница 13: ...problem special consideration must be taken to protect the pool and ancillary equipment if either is located outside If you have any questions regarding precautions to take against freezing please cal...

Страница 14: ...s not plugged in 5 Plug pump in Plug must lock into place 6 Swim current turned on 6 Condition is normal 7 Circulating pump turned off at keypad 7 Turn pump back on by pressing key 1 on keypad or wait...

Страница 15: ...14 TEST LOG...

Страница 16: ...Endless Pools 1601 Dutton Mill Rd Aston PA 19014 2931 800 910 2714 US 610 497 8693 fax www myendlesspool com 2008 VGB Complient D490071_en 0119 2019 Endless Pools...

Отзывы: