4
Assembly instructions ECOLINE 5560/5570/5580 17-03-2009
GB
III. Note on commercial use
According to German safety regulations BGV D34 (VBG 21), a DIN 30 693
approved hose rupture guard and a safety pressure regulator with an excess
pressure valve must be fitted when using the heater in a commercial setting (e.g.
at fetes). A hose rupture guard and a safety pressure regulator are not supplied.
IV. Operating instructions
1. Open the canister valve (3)
2. The toggle switch of the burner that will be ignited must be in the „ON“ position!
Press the safety pilot button at the back of the pole until it
it catches and at the same time press the red piezo ignition button at
the front of the pole.
Keep the safety pilot button pressed for about 20 seconds
after ignition. This activates the flame control.
In the rare case that the heater does not ignite after the piezo ignition button has
been pressed 4 or 5 times, repeat the procedure 5 minutes
later.
Note:
It is possible to ignite the unit using other primers (matches, fire sticks)
through the opening in the grid.
V. Switching off
1. To switch of the unit, close the canister valve (3).
2. To turn off a single burner, the toggle switch above the piezo ignition
button should be in the „OFF“ position.
VI. Turning on and turning off a single burner
Both burners can be turned on or off independently of each other.
Turning on is described in point IV.
Turning off is described in point V.
VII. Storage tips
Remove the pressure regulator with the gas hose from the gas canister
by turning the cap nut (1) clockwise.
Always check that the sealants are intact.
If you discover or suspect damage,
contact your supply or filling station.
Never keep liquid gas canisters in the house,
underground or in airless rooms!