5
Assembly instructions ECOLINE 5560/5570/5580 17-03-2009
GB
VIII. Important safety information
Note
: Only use outdoors or in well-ventilated rooms.
(The definition of a well-ventilated room is that at least 25% of the surrounding
area is open. The surrounding area is the sum of all wall surfaces.)
1.
The unit must be installed and the liquid gas canister stored
according to the applicable regulations.
2.
The patio heater may not be used in living areas, basements, office spaces
or similar.
3.
The patio heater may only be used for heating purposes.
4.
The unit must be placed on a level and solid surface.
5.
Keep all liquid gas bottles out of direct sunlight.
6.
The unit must be placed in an area that has a volume of
at least 20 m3 per kW of nominal thermal stress and be well
ventilated (covered patio, beer tents, etc.)
7.
When in use, the unit must be placed at a safe distance from combustible
materials. The distance between the heat source
and combustible materials must not be less than 2 m in the direction of radiation.
Distance in other directions to combustible materials must not be less than 1 m.
8.
Check the existence and the condition (i.e. no damage)
of the sealant on the canister valve,
particularly when changing the canister. Do not use any additional sealants.
9.
The patio heater may only be operated using an intermediary pressure regulator
with an acceptable exit pressure (see the unit rating plate and the factory
settings).
10.
Check the sealant of all connections immediately after assembly.
A foaming agent (Enders Gas-Control-Spray, item no. 1196
or suds) should be used.
11.
Repairs and maintenance of gas-technical components may only be carried out
by authorised professionals.
12.
In case of malfunction, the canister valve (3)
should be closed.
13.
The patio heater should be switched off and the canister removed from
the canister holder before moving the unit to another location.
14.
The gas hose must not be bent.
15.
The gas hose should be inspected for damage at least once a month
and each time the canister is changed.
16.
The gas hose should be inspected every five years by an authorised
specialist.
17.
If the gas hose is damaged, it must be replaced by
a hose of the same quality and length.
18.
The ventilation holes on the container sleeve of the
canister must not be covered.
19.
Do not move the unit when it is switched on.
20.
Only use the gas types and canisters recommended by the manufacturer!
5560_5570_5580_Ecoline_DE_GB_FR_170309.indd 5
17.03.2009 13:35:36 Uhr