EDM01-33v1 DAG_7.5G4_Card_User_Guide
©2008 Endace Technology Ltd. Confidential - Version 1 - November 2008
19
To view the FPGA image revision strings, type the following:
dagrom -d0 -x
where "0" is the device number of the DAG card you wish to capture data from
Output DAG 7.5G4:
factory: edag75g4pci_dsm_pci_v2_5 5vlx85tff1136 2008/11/12 10:19:01
user 1: edag75g4pci_dsm_pci_v2_5 5vlx85tff1136 2008/11/12 10:19:01(active)
user 2:
user 3:
Card Serial: 3006575
Preparing the DAG card for use
Before configuring the DAG 7.5G4 card you must run the following
dagconfig
command to
set the default parameters in the DAG card. This ensures the DAG 7.5G4 card functions
correctly once you begin capturing data.
Note:
Ensure you run this command each time the FPGA is reprogrammed.
dagconfig -d0 default
where "0" is the device number of the DAG card you wish to capture data from.
The current DAG 7.5G4 configuration displays and the firmware is verified as correctly
loaded. See
dagconfig
(page ) for more information.