background image

 

2

Functions Description

 

 

Function 

Description 

Door Unlock Time Setting 

Assign 

Door Unlock Time

 (or 

Door Relay Activated Time

). The 

Door Unlock 

Time

 is keypad programmable and can be programmed as- 

Toggle Mode

Latched-on

/

Latched-off

 

or   

Momentary Mode

: 1 ~ 600 seconds or 0.1 ~ 39.9 seconds. 

Default setting: 2 seconds. 

Alarm Time Setting 

Assign 

Alarm Time

 (or 

Alarm Relay Activated Time

). The 

Alarm Time

 is 

keypad programmable and can be programmed as- 

Latched-on Mode

 or   

Momentary Mode

: 1 ~ 600 seconds 

Default setting: 2 seconds. 

Arming Delay Time Setting 

Once the arming function is set, after a certain period of 

Arming Delay Time

the system will enter 

Arming Mode

 and 

1)

 the system engages the 

Timing 2 

Sequences

 if door is close or 

2)

 wait until door is closed to engage the 

Timing 2 

Sequences

 if door is open. By setting 

Arming Delay Time

, user can have 

enough  time to go out without activating the alarm system. The 

Arming Delay 

Time

 is keypad programmable and can be programmed from 1 ~ 600 seconds. 

Default setting: 1 second. 

Alarm Delay Time Setting 

When the door is close and the system is in 

Arming Mode

, open  the door will 

activate the alarm relay after a certain period of delay time (

Door Unlock Time

 

Arming Idle Time

 + 

Alarm Delay Time

). To avoid the alarm generated, user 

can close the door within "

Door Unlock Time

 + 

Arming Idle Time

" delay period 

and system is still in 

Arming Mode

, or just enter disarm process within "

Door 

Unlock Time

 + 

Arming Idle Time

 + 

Alarm Delay Time

" period and system is in 

Disarming Mode

.

 

The 

Alarm Delay Time

 

is keypad programmable and can be 

programmed from 1 ~ 600 seconds. 
Default setting: 3 seconds. 
 
If door is opened and in 

Latched-off

 mode, the delay time is infinite and there 

will be no alarm activated. 

Arming Idle Time Setting 

This idle time can provide user an enough time to close the door without 
entering 

Alarm Delay Time

 period. Once system enters 

Alarm Delay Time

 

period, the user has to disarm the system to avoid the alarm generated. The 

Arming Idle Time

 

is keypad programmable and can be programmed from 1  - 

600 seconds. 
Default setting: 15 seconds. 

Power on Arming 

After power on, the arming is set automatically and system enters 

Time 1 

Sequence

. This feature is keypad programmable. Please refer to 

Command 20

.

 

Default setting: Disable power on

 Arming

Door Monitored & Re-lock 

To prevent "tailgating", door is monitored and automatically locked when entry is 
completed and door is closed for at least 2 seconds. 
This feature is keypad programmable and isn't effective if the 

Door Unlock 

Time

 setting is in 

Latched-on

 mode. Please refer to 

Command 20

Default setting: Disable 

Auto

 

Re-lock

 function. 

Door Exit Release  

A door exit push-button or infrared detector to unlock the door from inside. 
This feature is keypad programmable. Please refer to 

Command 20

(Note: Push-button switch or infrared detector is not included). 
Default setting: Enable 

Door Exit Release

 function. 

Audible output 

Audible beep sound to indicate the status of key pressed or successful operation 
or operation failed. 

Edit Mode Timeout 

If no entry is made within 30 seconds, the system will exit the 

Edit Mode

 and 

return to its normal operation, i.e. 

User Mode

Keypad Automatic Blocking 

Keypad will be locked for 30 seconds if wrong key -entries are made 3 times in 

User Mode

. A valid or invalid card can release the keypad from blocking during 

these 30 seconds. 
For all the valid inputs, either by cards or by keys, the error counter will reset to 
0. 
For the invalid card input, the error counter will reset to 1. 

Содержание 721H5

Страница 1: ...Proximity Access Control System 721H5 OPERATION MANUAL Ver 3 2 Date 07 05 2001 ...

Страница 2: ...nal 721L module the 701H5 can be performed as On Line Reader LED Indicators LED Status Description LED GREEN blinking every 1 5 seconds LED GREEN on off moderately LED GREEN blinking every 0 6 seconds LED GREEN on off fast LED GREEN on LED RED on LED RED on off fast LED RED blinking every 0 4 seconds Power on in User Mode normal condition System waits for PIN or Function Code inputs completed The ...

Страница 3: ...off mode the delay time is infinite and there will be no alarm activated Arming Idle Time Setting This idle time can provide user an enough time to close the door without entering Alarm Delay Time period Once system enters Alarm Delay Time period the user has to disarm the system to avoid the alarm generated The Arming Idle Time is keypad programmable and can be programmed from 1 600 seconds Defau...

Страница 4: ...ent card with address 00000 to the reader and input PIN Code and sign if the card is in Card and PIN Code access mode 2 Press key in 3 seconds PPPPPP 6 digit Password Either way can enter Edit Mode Default setting PPPPPP 123456 or Either way can exit Edit Mode and then in User Mode however will also set the arming 00 NNN Assign a Reader Number 001 254 to itself If NNN 000 or NNN 254 system will as...

Страница 5: ...llowed with DEV to activate the Alarm Relay FFFF 0001 9999 Default setting FFFF 1234 18 TTT Arming Idle Time Setting 1 600 seconds TTT 001 600 If TTT 600 system will assign a default setting Default setting TTT 015 19 SSSSS NNNNN Register a number of card s to the system After registered the cardholder can access the system by using Card Only mode Note Cards can not be registered through 721K or 7...

Страница 6: ... disable disable enable 144 disable enable enable enable 146 enable enable enable enable 152 disable disable enable enable 154 enable disable enable enable If NNN 255 system will assign a default setting Default setting NNN 024 26 SSSSS EEEEE X Define the proximity cards with addresses starting from SSSSS to EEEEE to have or not to have an anti passback feature For example If enter 26 00005 00008 ...

Страница 7: ...Code 1234 Auto Re Lock Disable Power on Arming Disable Door Exit Release Enable Anti passback Disable Hardware Specifications Power Input 10 12 VDC Power Consumption 200mA Door Relay Output COM NC and NO 2A 30VAC 2A 24VDC Alarm Signal Output Transistor output active low 12VDC 100mA Max Tamper Switch Output 1 SPDT 1A 24VAC 1A 24VDC Door Monitor Input C and NC contacted when door closed Door Exit Re...

Страница 8: ... 100 mA 12VDC Max YELLOW ORANGE RED CN3 CN2 CN1 TAMPER SWITCH 1A 24VAC 1A 24VDC NC C NO WHITE PURPLE W NC C GND Power To Lock POSITIVE BLUE W WHITE NO C GND LOCK POSITIVE Power To Open GRAY BLUE DAT 1 721K CN2 BLUE DAT 0 721K CN2 GREEN LED G 721K CN2 BROWN LED R 721K CN2 YELLOW 721K CN2 PINK BUZZ BUZZER OUTPUT CN2 CN1 721H5 PCB or 721U BLUE or 721U GREEN or 721U PURPLE or 721U BROWN or 721U YELLOW...

Страница 9: ...ED G BROWN YELLOW BUZZER INPUT PINK BUZZ WIEGAND WIRING LED INPUT BUZZER INPUT ABA II OUTPUT CN2 LED G LED R BROWN YELLOW CLOCK DATA BUZZ CARD PRESENT ORANGE PINK N A N A BLUE GREEN ABA II WIRING 1A 24VDC 1A 24VAC TAMPER SWITCH CN3 ORANGE YELLOW NO C RED NC CN3 WG ABA BITS WG ABA BITS WG ABA BITS ABA II WG ABA BITS Wiegand 26 Bits Wiegand 34 Bits ...

Страница 10: ...A LED G BUZZ IN BLUE GREEN PURPLE BROWN ABA II WIRING 9 12 VDC GND BLACK RED 721U PCB 34 26 ABA Wiegand 34 BITS ABA 34 26 ABA Wiegand 26 BITS 34 26 ABA 34 26 ABA II GREEN GREEN RS485 B 12VDC RED RS485 TO 701E 704E 716E RS485 A BLUE YELLOW BLACK CONTROLLER RS 232 34 26 ABA BUZZ IN TTL INVERTED SERIAL OUTPUT BUZZ OUT CARD PRESENT BUZZER OUTPUT BUZZER INPUT GRAY PURPLE GREEN WHITE 9 12 VDC LED G TTL ...

Страница 11: ...o turn off the alarm which is activating Door opened by using Forced Open and if Forced Open feature Command 28 is disabled In arming situation the system enters A Al la ar rm m D De el la ay y T Ti im me e right away once the door is opened by using Forced Open and if Forced Open feature is disabled The alarm is activated after T Ti im me e P Pe er ri io od d D D User can disarm the system in T T...

Страница 12: ... Card E is registered system assigns group 01 and address 00004 to it The system is still in 19 00005 00001 command 12 00001 1234 Assign PIN Code 1234 to Card with address 00001 I E Card B 19 00005 00001 Register Command Individual registration Present Card C Card C was registered before five beep tones are generated to indicate this error The system is still in 19 00005 00001 command 19 00005 000...

Страница 13: ...ds PIN Code has to be entered in 3 seconds after present card 123456 PASSWORD ERROR New password is 654321 Error count is 1 123456 PASSWORD ERROR New password is 654321 Error count is 2 Invalid Card Present Invalid card present error count reset to 1 Present Card A Valid card present error count reset to 0 123456 PASSWORD ERROR New password is 654321 Error count is 1 123456 Wrong password Error co...

Страница 14: ...unction Code present Card J 9999 5555 There are 3 seconds timeout between present valid card and Function Code between PIN Code and Function Code i e User has 3 seconds to start inputting the Function Code There are 5 seconds timeout between valid address and PIN Code between present valid card and PIN Code between each key pressed i e User has 5 seconds to start inputting the PIN Code If last pre...

Страница 15: ...ign a PIN Code PPPP to an individual card with address SSSSS After assigned the cardholder can access the system by using Card or PIN Code mode 13 SSSSS PPPP Assign a PIN Code PPPP to an individual card with address SSSSS After assigned the cardholder can access the system by using Card and PIN Code mode 17 FFFF Assign 4 digit Function Code FFFF 18 TTT Arming Idle Time Setting 1 600 seconds 19 SSS...

Страница 16: ...rd 5 digits in the left called Site Code and 5 digits in the right called Card Code System can accept only the Card Code in the range from 00001 to 65200 cards with continuous codes is required 721H7 The 721H7 is a self contained and non tracking standalone Proximity Door Access Elevator Control Reader It supports up to 1000 cardholders for Door Access Control and 630 cardholders for Elevator Cont...

Страница 17: ...ee access modes Card and PIN Code or Card or PIN Code or Card Only There is a 10 digit number in each card 5 digits in the left called Site Code and 5 digits in the right called Card Code 721H5 721L On Line Proximity Reader The 721H5 721L On Line Proximity Reader is for Networking Proximity Access Control System The networking system with maximum 5000 cardholders can connect up to 254 any combinat...

Страница 18: ...tall outside or 721U install inside secured area CASE 4 721H5 secured area install outside CASE 3 721H5 721L to 701E 704E 716E Controller RS485 to 701E 704E 716E Controller 721L RS485 wire connection wire connection wire connection 721K or 721U install outside unsecured area READER READER READER READER READ HEAD READ HEAD ON LINE MODULE ON LINE MODULE ...

Страница 19: ...ill be on if gray wire buzz output and purple wire are connected and card is presented 721U LED G LED R will be on if white wire card present and brown wire yellow wire is connected and card is presented 1N4148 Two 1N4148s have to be added to 721U side if there are more than two read heads are connected to 721H Reader For example NOTE If 1x721K 1x721U are connected then 2 1N4148s added to 721U sid...

Отзывы: