Functions Description
Function
Description
Door Unlock Time Setting
Assign
Door Unlock Time
(or
Door Relay Activated Time
). The
Door Unlock
Time
is keypad programmable and can be programmed as-
Toggle Mode
:
Latched-on
/
Latched-off
or
Momentary Mode
: 1 ~ 600 seconds or 0.1 ~ 39.9 seconds.
Default setting: 2 seconds.
Alarm Time Setting
Assign
Alarm Time
(or
Alarm Relay Activated Time
). The
Alarm Time
is
keypad programmable and can be programmed as-
Latched-on Mode
or
Momentary Mode
: 1 ~ 600 seconds
Default setting: 2 seconds.
Arming Delay Time Setting
Once the arming function is set, after a certain period of
Arming Delay Time
,
the system will enter
Arming Mode
and
1)
the system engages the
Timing 2
Sequences
if door is close or
2)
wait until door is closed to engage the
Timing 2
Sequences
if door is open. By setting
Arming Delay Time
, user can have
enough time to go out without activating the alarm system. The
Arming Delay
Time
is keypad programmable and can be programmed from 1 ~ 600 seconds.
Default setting: 1 second.
Alarm Delay Time Setting
When the door is close and the system is in
Arming Mode
, open the door will
activate the alarm relay after a certain period of delay time (
Door Unlock Time
+
Arming Idle Time
+
Alarm Delay Time
). To avoid the alarm generated, user
can close the door within "
Door Unlock Time
+
Arming Idle Time
" delay period
and system is still in
Arming Mode
, or just enter disarm process within "
Door
Unlock Time
+
Arming Idle Time
+
Alarm Delay Time
" period and system is in
Disarming Mode
.
The
Alarm Delay Time
is keypad programmable and can be
programmed from 1 ~ 600 seconds.
Default setting: 3 seconds.
If door is opened and in
Latched-off
mode, the delay time is infinite and there
will be no alarm activated.
Arming Idle Time Setting
This idle time can provide user an enough time to close the door without
entering
Alarm Delay Time
period. Once system enters
Alarm Delay Time
period, the user has to disarm the system to avoid the alarm generated. The
Arming Idle Time
is keypad programmable and can be programmed from 1 -
600 seconds.
Default setting: 15 seconds.
Power on Arming
After power on, the arming is set automatically and system enters
Time 1
Sequence
. This feature is keypad programmable. Please refer to
Command 20
.
Default setting: Disable power on
Arming
.
Door Monitored & Re-lock
To prevent "tailgating", door is monitored and automatically locked when entry is
completed and door is closed for at least 2 seconds.
This feature is keypad programmable and isn't effective if the
Door Unlock
Time
setting is in
Latched-on
mode. Please refer to
Command 20
.
Default setting: Disable
Auto
Re-lock
function.
Door Exit Release
A door exit push-button or infrared detector to unlock the door from inside.
This feature is keypad programmable. Please refer to
Command 20
.
(Note: Push-button switch or infrared detector is not included).
Default setting: Enable
Door Exit Release
function.
Audible output
Audible beep sound to indicate the status of key pressed or successful operation
or operation failed.
Edit Mode Timeout
If no entry is made within 30 seconds, the system will exit the
Edit Mode
and
return to its normal operation, i.e.
User Mode
.
Keypad Automatic Blocking
Keypad will be locked for 30 seconds if wrong key -entries are made 3 times in
User Mode
. A valid or invalid card can release the keypad from blocking during
these 30 seconds.
For all the valid inputs, either by cards or by keys, the error counter will reset to
0.
For the invalid card input, the error counter will reset to 1.