Operational Status
The TAM-242 is a self contained unit and as such the only checks that can be made are when
charging the battery or changing the unit
’s state from on to off or vice versa. In all of these cases the
LED function is as per the following table:
Operation
LED Status
Duration
Remarks
Normal Operation
–
Position Reporting and
“Awake” to Receive
Message
Flashing
–
Colour
indicates
charge level
One second on, two
seconds off for up to
10 minutes
The colour indicates the
charge status, Green >90%,
Orange 25% to 90%, Red
<25%. Terminal will enter
Sleep Mode between
transmissions (no LED)
Switch Off with Key
Switch
ON
Six seconds
LED will remain off until the
terminal is switched on or
charged
Switch On with Key
Switch
Flashing
One second on, two
seconds off for up to
10 minutes
Immediately transmits a
position report
Charging
ON
– Red or
Orange
Continuous
There is a fault
Charging
Flashing - Red
Five seconds on, three
seconds off
Battery charge at <90%
Charging
Flashing -
Green
Five seconds on, three
seconds off
Battery charge at >90%
Charging
ON - Green
Continuous
Battery full