30786-7-0415
Page 10
GLASS FRONT
6 3/8”
SEE MANTLE CHART FOR
MAXIMUM MANTLE DEPTH
2” x 4” HEADER
STAND OFF
3” (76 mm) HEIGHT
ABOVE TOP OF
FIREPLACE
NAILING
FLANGES
TOP FRAMING
LEDGE
NON-COMBUSTIBLE
FIRST 6 3/8” (SEE
MAGNIFIED VIEW)
FINISHED WALL
(COMBUSTIBLE)
SEE MANTLE CHART
FOR MINIMUM HEIGHT
OF MANTLE ABOVE UNIT
Figure 2
combustible Material
Do not attach combustible material to the mantel of your fireplace.
This is a fire hazard. No greeting cards, stockings or ornamentation
of any type should be placed on or attached to the fireplace. This is
a heating appliance. The flow of heat can ignite combustibles.
Mantel chart (Figure 3)
MANTEL
18 3/8”
17 1/8”
14 3/8”
12 3/8”
11 3/8”
10 3/8”
9 3/8”
8 3/8”
7 3/8”
6 3/8”
2 1/4”
1 1/2”
3/4”
8”
6”
4 1/2”
3 3/4”
3”
12” (305mm)
10” (254mm)
TOP EDGE OF FIREPLACE
COMBUSTIBLE TRIM AND MANTELS
ALLOWED IN SHADED AREA
Figure 3
Clearance to Combustibles
Air Drop (End)
1/2" (12.7 mm)
Side
1/2" (12.7 mm)
Floor
0" (0 mm)
Top Stand-off
0" (0 mm)
Top Framing Edge
6 3/8" (161.7 mm)
cLeArAnces
Figure 4a - see through Fireplace clearances
36”
MIN.
42”
MIN.
(CEILING TO
TOP OF DOOR)
1 3/4” MIN.
PERPENDICULAR
COMBUSTIBLE
SIDEWALL
36”
MIN.
42”
MIN.
(CEILING TO
TOP OF DOOR)
1 3/4” MIN.
PERPENDICULAR
COMBUSTIBLE
SIDEWALL