Important

  1. The following service procedures are provided as a general 

guide.  

  2.  Meter readings between gas control and ignition module must 

be taken within the trial for ignition period.  Once the ignition 

module locks out, the system must be reset by turning the valve 

off for at least one minute before continuing.

  3.  If any component does not function properly,  make sure it is 

correctly installed and wired before replacing it.

  4.  The ignition module cannot be repaired.  If it malfunctions, it 

must be replaced.

  5.  Only trained, experienced service technicians should service 

intermittent pilot systems. 

Perform the 

CHECKOUT

  steps  on  page  15  as  the  first  step  in 

troubleshooting. Then check 

TROUBLESHOOTING GUIDE 

to 

pinpoint the cause of the problem.  If troubleshooting indicates an 

ignition problem, see Ignition System Checks below to isolate and 

correct the problem.
Following troubleshooting, perform the 

CHECKOUT

 procedure 

(page 15) again to be sure system is operating normally.

Ignition System Checks

Step 1:

  Check ignition cable.

Make sure:

  A.  Ignition cable does not touch any metal surfaces.

  B.  Ignition cable is no more than 36 inches long.

  C.  Connections to the ignition module and to the  igniter-sensor 

are clean and tight.

  D.  Ignition cable provides good electrical continuity.

Step 2:

   Check ignition system grounding.

 

Nuisance shutdowns are often caused by a poor or erratic 

ground.

  A.  A common ground, usually supplied by the pilot burner bracket, 

is required for the module and the pilot burner/igniter sensor.

•  Check for good metal-to-metal contact between the pilot 

burner bracket and the main burner.

•  Check the ground lead from GND (BURNER) terminal on the 

module to the pilot burner.  Make sure connections are clean 

and tight.  If the wire is damaged or deteriorated, replace it 

with No.  14-18  gauge, moisture-resistant, thermoplastic 

insulated wire with 105 C (221 F) minimum rating.

•  If flame rod or bracket are bent out of position, restore to 

correct position.

•  Replace pilot burner/igniter sensor if insulator is cracked.

Step 3:

  Check spark ignition circuit.  

You will need a short jumper 

wire made from ignition cable or other heavily insulated 

wire.

  A.  Close the manual gas valve.

  B. Disconnect the ignition cable at the SPARK terminal on the 

module.

WARNING

When performing the following steps, do not touch stripped end of 

jumper or SPARK terminal.  The ignition circuit generates 13,000 

volts at 25 pf load and electrical shock can result.

  C. Energize the module and immediately touch one end of the 

jumper firmly to the GND terminal on the module.  Move the 

free end of the jumper slowly toward the SPARK terminal until 

a spark is established.

  D. Pull the jumper slowly away from the terminal and note the 

length of the gap when sparking stops.  Check table below.

ARC LENGTH

ACTION

No arc or arc less than 

1/8 inch

Arc 1/8 inch or longer

Check external fuse, if provided.

Verify power at module input terminal.

Replace module if fuse and power 

okay.

Voltage output is okay.

Step 4:

  Check pilot flame current.

  A.  Turn off furnace.

  B.  Disconnect main valve wire from the TH or MV terminal on the 

gas control.

 C. Disconnect ground wire from GND (BURNER) terminal at 

module.

  D.  Connect a meter (dc microamp scale) in series with the ground 

lead.  

•  Disconnect ground lead from GND terminal on ignition module.

•  Connect the black (negative) meter lead to the ignition module 

GND (BURNER) terminal.

•  Connect the red (positive) meter lead to the free end of the 

ground lead.

  E.  Turn valve on to call for heat.  The spark will light the pilot but 

the main burner will not light because the main valve actuator 

is disconnected.

  F.  Read the meter.  The flame sensor current must be steady and 

at least 1.0 uA.

  G.  If the reading is less than the minimum or unsteady,

•  Make sure pilot flame envelopes 3/8 to 1/2 inch of the flame 

rod.  

•  If necessary, adjust pilot flame by turning the pilot adjustment 

screw on the gas control clockwise to decrease or counter-

clockwise  to  increase  pilot  flame.    Following  adjustment, 

always replace pilot adjustment cover screw and tighten 

firmly to assure proper gas control operation.

•  Check for cracked ceramic insulator, which can cause short 

to ground, and replace igniter-sensor if necessary.

•  Make sure electrical connections are clean and tight.  Replace 

damaged wire with moisture-resistant No. 18 wire rated for 

continuous duty up to 105 C (221 F).

  H.  Remove meter and reconnect all wires. Return system to normal 

operation before leaving job.

TROUBLESHOOTING

Содержание DVC55IPXLP-1

Страница 1: ...cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier INSTALLER Leave this manual with the appl...

Страница 2: ...7 Specifications 7 Gas Supply 8 9 Clearances 9 Installation Instructions 10 12 Lighting Instructions 13 Pilot Flame Characteristics 14 Main Burner Flame Characteristics 14 Wiring 15 Service and Maint...

Страница 3: ...The appliance should be inspected before use and at least annually by a qualified service person More frequent cleaning may be required due to excessive lint from carpet ing bedding materials etc It i...

Страница 4: ...can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity Propane Gas may stratify in a c...

Страница 5: ...oxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certified 3 SIGNAGE A metal or plastic identification plate shall be pe...

Страница 6: ...k and light colored tile Installation in Residential Garages Gas utilization equipment in residential garages shall be installed so that all burners and burner ignition devices are located not less th...

Страница 7: ...ntal pitch as required in the National Fuel Gas Code ANSI Z223 1 NFPA 54 or the Natural Gas and Propane Installation Code CSA B149 1 and these instructions Determine that there is no blockage or restr...

Страница 8: ...e vicinity of the unit Where none exists or where its size or location is not adequate contact your local authorized installer for installation or relocation Compounds used on threaded joints of gas p...

Страница 9: ...nter a building The bottom of the vent terminal and the air intake shall be located at least 12 inches above grade WARNING The nearest point of the vent cap should be a minimum horizontal distant of s...

Страница 10: ...es using the register as a template 4 Drill 2 1 8 diameter holes in cabinet side and fasten the register in place with 2 10 x 1 screws provided Side outlet kit 10 boot assembly with register SOK 1 for...

Страница 11: ...ed to the furnace INSTALLATION INSTRUCTIONS CONT D Cutting Vent Tubes This is the most important part of the installation With the furnace installed on wall the 6 diameter air inlet tube and the 4 dia...

Страница 12: ...or on Siding vinyl aluminum etc Direct vent furnaces are designed to be installed on a uniform outside wall When the wind comes from any angle up down or from either side it must hit the vent cap equ...

Страница 13: ...s control which has been under water OPERATING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE 1 Turn off all electric power to the appliance if service is to be performed 2 Remove control access panel lowe...

Страница 14: ...pilot flame and the spark gap are factory checked and tested After use cleaning may be required for the proper flame The correct flame will be a short blue inner flame with a much larger light blue ou...

Страница 15: ...ian Electrical Code CSAC22 1 if an external electrical source is utilized This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged di...

Страница 16: ...h all open close switch type 24 Vac capable of supplying rated voltage and current to the module AMBIENT TEMPERATURE RATING Minus 40 F to plus 175 F minus 40 C to plus 79 C RELATIVE HUMIDITY RATING 5...

Страница 17: ...ety lockout Lockout de energizes the first main valve operator and closes the first main valve in the gas control stopping pilot gas flow The control system must be reset by turning the valve off for...

Страница 18: ...made from ignition cable or other heavily insulated wire A Close the manual gas valve B Disconnect the ignition cable at the SPARK terminal on the module WARNING Whenperformingthefollowingsteps donott...

Страница 19: ...37403 5 0620 Page 19 TROUBLESHOOTING CONT D...

Страница 20: ...ation after a one minute delay Check transformer and AC line for prop er input voltage to the control Check with full system load on the transformer 6 2 Failed trial for ignition resulting in lockout...

Страница 21: ...se and can be ordered by your Service Person or Dealer Proof of purchase is required for warranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model...

Страница 22: ...ng 29 DV824 Front Burner 30 P8842 Main Burner Orifice Natural Gas Two Required 30 P8853 Main Burner Orifice Propane Gas Two Required 31 DV687 Manifold and Plate Assembly 32 M148 Manifold Gasket 33 M15...

Страница 23: ...37403 5 0620 Page 23 PARTS VIEW...

Страница 24: ...a qualified installer and operated in accordance with the instructions furnished with the appliance A bill of sale cancelled check or payment record should be kept to verify purchase date and establis...

Страница 25: ...impossible de joindre le fournisseur de gaz appeler le service d incendie L installation et l entretien doivent tre ex cut s par un installateur qualifi une agence de service ou par le fournisseur de...

Страница 26: ...ventiler l appartement dans lequel l unit est install e Installation sur un Tapis ou Tuile Si cet appareil est install directement sur un tapis tuiles ou tout genre de mat riel combustible autre qu un...

Страница 27: ...ts d un syst me de ventilation de taille inad quate formation de condensat fuite d versement etc et doivent sp cifier la proc dure d essai suivante AVERTISSEMENT DANGER D EMPOISONNEMENT AU MONOXYDE DE...

Страница 28: ...ou les endroits bas Attendez que les pompiers vous assurent de la s ret de ces endroits avant d y aller Utiliser le t l phone de votre voisin et appeler les pompiers et une personne entra n e avec le...

Страница 29: ...d sir e pour la sortie d air et marquer les trous de montage en utilisant le registre comme guide 10 Percer 2 trous de 1 8 3 2mm de diam tre dans le mur et attacher le registre avec 2 vis 10 x 1 2 54c...

Страница 30: ...placement de l Alimentation de Gaz Lalignedegazpeutentrerdansl appareilsoitenvenantduplancher ou du mur ext rieur L ouverture pour la ligne de gaz doit tre faite ce moment L emplacement de l ouverture...

Страница 31: ...tre ait une l g re pente descendante vers l ext rieur La pente descendante est n cessaire pour pr venir l entr e de la pluie Attacher la plaque ext rieure de montage au mur ext rieur avec 4 vis 10 x 1...

Страница 32: ...xtention du capuchond ventpourrev tementenvinylenedoitpasexc derune paisseurtotalede13 33 02cm pourleDVC 55 voirFigure5a AVERTISSEMENT Lorsque l ensemble d vent pour le rev tementenvinyleDV 822oulacon...

Страница 33: ...taller un collecteur de s diment avec un adapteur en T L emploi des connexions de gaz suivantes est recommand ANS Z21 24 Connexions d appareil de tuyaux et de raccords en m tal ondul ANS Z21 45 Connex...

Страница 34: ...ch e dans l adapteur La bo te de jonction est munie d un trou de 7 8 22 2mm pour utiliser un raccord conducteur si les codes locaux exigent ce genre de protection Installation d un dispositif de march...

Страница 35: ...nneau d acc s la commande panneau du bas avant 3 Tourner le bouton de contr le de gaz dans le sens horaire la position ferm Ne pas forcer 4 Replacer le panneau d acc s la commande panneau du bas avant...

Страница 36: ...z allant la veilleuse ou au br leur principal E Attendre une minute avant de continuer TAPE 5 V rifier le fonctionnement normal A R gler plus lev e que celle de la chambre pour obtenir de la chaleur B...

Страница 37: ...nt tre identifi s avant de les d brancher Une erreur de filetage piut entra ner un mauvais et dangereux fonctionnement V rifier que le fonctionnement soit convenable apr s l entretien STAGE 1 TRIAL FO...

Страница 38: ...p riode d essai d allumage Lorsque le module d allumage se verrouille le syst me doit tre remis z ro en r glant le temp rature plus basse que celle de la chambre pour au moins une minute avant de cont...

Страница 39: ...s il y a lieu V rifier l enveloppe du c ble d allumage pour des signes de fonte ou de d formation Prendre les moyens pour prot ger le c ble et l enveloppe contre les temp ratures excessives V rifier q...

Страница 40: ...2147 Valve de gaz VR8204C 1126 gaz propane 10 0 41 R 2149 Valve de gaz VR8204C 1001 gaz naturel 3 5 42 UH 810 Support de montage pour transformateur 43 R 1995 Transformateur 44 UH 451 Couvercle pour b...

Страница 41: ...37403 5 0620 Page 17...

Страница 42: ...37403 5 0620 Page 18 MAINTENANCE HISTORIQUE DE L APPAREIL Date Nom du distributeur Nom du technicien de service Entretien effectu notes...

Страница 43: ...37403 5 0620 Page 19 MAINTENANCE HISTORIQUE DE L APPAREIL Date Nom du distributeur Nom du technicien de service Entretien effectu notes...

Страница 44: ...Empire Comfort Systems Inc Belleville Illinois Pour toute question g n rale concernant nos produits veuillez nous envoyer un courriel info empirecomfort com Pour toute question d entretien ou de r pa...

Отзывы: