background image

12430-3-0903

 Page 19

Parts can be ordered

 only

 through your 

service person or dealer.

 For best results, the 

service person or dealer

 should order parts through

the distributor. Parts can be shipped directly to the 

service person/dealer

.

All parts listed in the Parts List have a Part Number. When ordering parts, first obtain the Model Number from the name plate on your
equipment. Then determine the Part Number (

not

 the Index Number) and the Description of each part from the following appropriate

illustration and list. Be sure to give all this information . . .

Furnace Model Number

Part Description 

Furnace Serial Number 

Part Number 

Type of Gas (Propane or Natural) 

Do not order bolts, screws, washers or nuts. They are standard hardware items and can be purchased at any local hardware store.

Shipments contingent upon strikes, fires and all causes beyond our control.

HOW TO ORDER REPAIR PARTS

Empire Comfort Systems, Inc. 

Nine Eighteen Freeburg Ave.  Belleville, IL 62222-0529

PARTS LIST

PLEASE NOTE:  

When ordering parts, it is very important that  

part number

 and 

description

 of part coincide.

INDEX

PART

  NO.

NUMBER

DESCRIPTION

INDEX

PART

  NO.

NUMBER

DESCRIPTION

1

DV-1213

TOP PLATE

2

R-3165

DOOR CLIP (2 REQUIRED)

3

DV-1204

CASING SIDE - RIGHT

4

DV-1202

CASING BACK

5

DV-1205

CASING SIDE - LEFT

6

DV-1249

AIR DROP

7

DV-1230

TURBULATOR (3 REQUIRED)

8

DV-1233

OUTLET BOX REAR

9

DV-1224

OUTLET BOX COVER

10

R-3161

FAN BLADE

11

R-3166

FAN MOTOR

12

DV-1246

MOTOR MOUNTING BRACKET

13

8720130

BUSHING (4 REQUIRED)

14

8520141

RUBBER GROMMET
(4 REQUIRED)

15

8520142

BRASS BUSHING
(4 REQUIRED)

16

R-3164

DOOR CLIP (2 REQUIRED)

17

DV-1251

INNER SHIELD - RIGHT (INCLUDES
NO. 22)

18

R-6176

FAN CONTROL SWITCH

19

R-3175

LIMIT SWITCH

20

DV-1255

INNER SHIELD FRONT (USA)

20

15666

INNER FRONT ASSEMBLY
(CANADA)

21

DV-1253

INNER SHIELD COVER PLATE (2
REQUIRED)

22

DV-1252

INNER SHIELD -LEFT (INCLUDES
NO. 22)

23

DV-1257

EXCHANGER ASSEMBLY

24

R-3162

FILTER

25

R-3163

FILTER RETAINER

26

R-3232

PILOT - NAT (IP ONLY)

26

R-3233

PILOT - LPG (IP ONLY)

27

742126

ORIFICE - NAT (3 REQUIRED)

27

P-88-61

ORIFICE - LPG (3 REQUIRED)

28

DV-1236

MANIFOLD

29

DV-1259

FRONT PANEL

30

722040

MANIFOLD UNION

31

852051

BUSHING 3/8 X 1/2

32

R-3170

GAS VALVE - NAT (IP ONLY)

32

R-3171

GAS VALVE - LPG (IP ONLY)

32

R-2148

GAS VALVE - NAT (SPP ONLY)

32

R-5655

GAS VALVE - LPG (SPP ONLY)

33

R-2708

PIEZO IGNITOR (SPP ONLY)

34

DV-781

OBSERVATION HOLE COVER WITH MICA

35

712098

GASKET - OBS HOLE

36

FF-160

PIEZO BRACKET (SPP ONLY)

37

DV-1240

BURNER COMPARTMENT FRONT

38

DV-1265

BURNER COMPARTMENT BODY

39

712059

GASKET - TUBE SEAL

40

DV-775

SEAL BRACKET (SPP ONLY)

40

DV-691

SEAL BRACKET (IP ONLY)

41

712045

MANIFOLD GASKET

42

DV-1235

PILOT BRACKET (IP ONLY)

43

R-3031

BURNER (3 REQUIRED)

44

DV-1239

BURNER BRACKET

45

UH-810

TRANSFORMER MOUNTING BRACKET (SPP
ONLY)

45

UH-452

TRANSFORMER MOUNTING BRACKET (IP
ONLY)

46

R-1995

TRANSFORMER (SPP ONLY)

46

8720100

TRANSFORMER (IP ONLY)

47

UH-451

JUNCTION BOX COVER

48

DV-572

JUNCTION BOX

49

872056

BUSHING

50

872053

CORD SET

51

8720148

BUSHING

52

DV-1215

BOTTOM PLATE

53

R-3034

PILOT - NAT (SPP ONLY)

53

R-3035

PILOT - LPG (SPP ONLY)

54

GWT-021

PILOT BRACKET (SPP ONLY)

55

R-3180

ELECTRODE AND WIRE (SPP ONLY)

56

R-2256

THERMOCOUPLE -18" (SPP ONLY)

57

R-6389

WALL THERMOSTAT - 24 VOLT

58

DV-1273

VENT KIT COMPLETE

59

DV-1355

FLUE OUTLET TUBE

60

DV-1354

AIR INLET TUBE

61

DV-131

OUTSIDE MOUNTING PLATE

62

DV-769

VENT CAP

NOT SHOWN

DV-1261

PILOT TUBING

NOT SHOWN

742158

PILOT ORIFICE - NAT (SPP ONLY)

NOT SHOWN

742266

PILOT ORIFICE - LPG (SPP ONLY)

NOT SHOWN

742154

PILOT ORIFICE - NAT (IP ONLY)

NOT SHOWN

R-3265

PILOT ORIFICE - LPG (IP ONLY)

NOT SHOWN

R-3172

WIRE HARNESS (SPP ONLY)

NOT SHOWN

R-3173

WIRE HARNESS (IP ONLY)

NOT SHOWN

R-3236

WIRE (IP ONLY)

 USE ONLY MANUFACTURER'S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH.

Содержание DVC-35-1IP

Страница 1: ...plier s instructions Ifyoucannotreachyourgassupplier call the fire department Installation and service must be per formed by a qualified installer service agency or the gas supplier WARNING If not ins...

Страница 2: ...Standing Pilot Lighting Instructions 11 DVC 35IP Intermittent Pilot Lighting Instructions 12 Pilot Flame Characteristics 13 Main Burner Flame Characteristics 14 Wiring 14 15 Service and Maintenance S...

Страница 3: ...by a qualified service person More frequent cleaning may be required due to excessive lint from carpeting bedding materials etc It is imperative that control compartments burners andcirculatingairpass...

Страница 4: ...service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on walls of n...

Страница 5: ...ing vehicle Qualified Installing Agency Installationandreplacementofgaspiping gasutilizationequipment or accessories and repair and servicing of equipment shall be performedonlybyaqualifiedagency Thet...

Страница 6: ...orized installer for installation or relocation Compoundsusedonthreadedjointsofgaspipingshallberesistant to the action of liquefied petroleum gases The gas lines must be checked for leaks by the insta...

Страница 7: ...ts in unsatisfactory performance 3 The DVC 35 can be attached to the wall or recessed into the wall up to 9 1 2 241mm in depth but the minimum 3 4 19mm vent air intake system wall depth must be main t...

Страница 8: ...1 25mm provided screws 9 Installation of SOR 1 is completed Side outlet kit SOK 1 10 254mm boot assembly with regis ter for warm air discharge into an adjoining room may be installed on either side o...

Страница 9: ...2mm diameter air inlet tube is placedasfaraspossibleontothecollaroftheairdropassembly Mark the 6 152mm diameter air inlet tube 1 2 13mm beyondtheoutsidewall Remove6 152mm diameterairinlet tube from co...

Страница 10: ...the wind on one side of the air inlet section will result in back pressure on the flue section smothering the flame and eventual pilot outage When the vent cap is to be installed on vinyl siding or i...

Страница 11: ...control knob slightly and turn clock wise to OFF Do not force 5 Replace control access panel lower front panel LIGHTING INSTRUCTIONS 1 STOP Read the safety information above 2 Set the thermostat to l...

Страница 12: ...n to inspect the appliance and to replace any part of the control system and any gas control which has been under water 1 STOP Read the safety information above 2 Set the thermostat to lowest setting...

Страница 13: ...tor which lights a pilot that in turn lights the main burner The gas valve used in this system is a step opening whichopensatalowerpressureforignitionandthenstepstoafull inlet pressure of 4 H2 O press...

Страница 14: ...r in the absence of local codes with the National Electrical Code ANSI NFPA 70 or Canadian Electrical Code CSA C22 1 if an external electrical source is utilized This appliance is equipped with a thre...

Страница 15: ...OUTLET PRESSURE REGULATOR ADJUSTMENT UNDER CAP SCR EW GAS FLOW IG NITOR C ONTROL TO 24 V THERMOSTA T TO 24 V COMMON ON TRANSFOR MER TO 24V HOT ON TRANSFORMER WIRING I P MODEL GAS VALVE AND WIRING IGNI...

Страница 16: ...Check pilot adjustment for being full open counterclockwise to open 3 Ifgasisavailableinthesupplytubing thepilotorificeand orpilotburnerisprobablyrestrictedbyaspiderweb Clean pilot assembly and religh...

Страница 17: ...Second Flame Failure Recycle Delay YES YES YES NO Pilot Valve Ignition OFF Wait for Flame Signal to Disappear 1 Ignitor will turn OFF about 30 seconds into the trial for ignition if the pilot flame ha...

Страница 18: ...and Back ON Main Burner Lights Replace SmartValve Control Check Transformer and Line Volt Supply Check that Pilot Flame Makes Good Contact with Pilot Burner Flame Rod Check for Good Electrical Connect...

Страница 19: ...666 INNERFRONTASSEMBLY CANADA 21 DV 1253 INNERSHIELDCOVERPLATE 2 REQUIRED 22 DV 1252 INNERSHIELD LEFT INCLUDES NO 22 23 DV 1257 EXCHANGERASSEMBLY 24 R 3162 FILTER 25 R 3163 FILTERRETAINER 26 R 3232 PI...

Страница 20: ...VIEW Empire Comfort Systems Inc Nine Eighteen Freeburg Ave Belleville Illinois 62220 2623 PH 1 800 851 3153 PH 1 618 233 7420 FAX 1 800 443 8648 FAX 1 618 233 7097 E MAIL info empirecomfort com WEB S...

Отзывы: