12430-3-0903
Page 5
INTRODUCTION
Introduction
Always consult your local Building Department regarding
regulations, codes or ordinances which apply to the installation of
a direct vent wall furnace.
Instructions to Installer
1.
Installer must leave instruction manual with owner after
installation.
2.
Installer must have owner fill out and mail warranty card
supplied with furnace.
3.
Installer should show owner how to start and operate furnace
and thermostat.
Warning:
Any change to this furnace or its control can be dangerous.
This is a heating appliance and any panel, door or guard
removed for servicing an appliance must be replaced
prior to operating the appliance.
General Information
This furnace is design certified in accordance with American
National Standard/CSA Standard Z21.86 and CSA 2.32 by the
Canadian Standards Association, as a fan type direct vent wall
furnace to be installed according to these instructions.
Any alteration of the original design, installed other than as
shown in these instructions or use with a type of gas not shown
on the rating plate is the responsibility of the person and
company making the change.
Important
All correspondence should refer to complete Model No., Serial
No. and type of gas.
Notice
: During initial firing of this unit, its paint will bake out and
smoke will occur. To prevent triggering of smoke alarms, ventilate
the room in which the unit is installed.
Installation on Rugs and Tile
If this appliance is installed directly on carpeting, tile or other
combustible material other than wood flooring the appliance shall
be installed on a metal or wood panel extending the full width and
depth of the appliance.
The base referred to above does not mean the fire-proof base as
used on wood stoves. The protection is for rugs that are extremely
thick and light colored tile.
Installation in Residential Garages
Gas utilization equipment in residential garages shall be installed
so that all burners and burner ignition devices are located not less
than 18" above the floor.
Such equipment shall be located, or protected, so it is not subject
to physical damage by a moving vehicle.
Qualified Installing Agency
Installation and replacement of gas piping, gas utilization equipment
or accessories and repair and servicing of equipment shall be
performed only by a qualified agency. The term "qualified agency"
means any individual, firm, corporation or company which either
in person or through a representative is engaged in and is responsible
for (a) the installation or replacement of gas piping or (b) the
connection, installation, repair or servicing of equipment, who is
experienced in such work, familiar with all precautions required
and has complied with all the requirements of the authority having
jurisdiction.
State of Massachusetts:
The installation must be made by a
licensed plumber or gas fitter in the Commonwealth of
Massachusetts.
The installation must conform with local codes or, in the absence
of local codes, with the
National Fuel Gas Code ANSI Z223.1/
NFPA 54* Natural Gas and Propane Installation Code, CSA
B149.1.
*Available from the American National Standards Institute, Inc., 11 West 42nd
St., New York, N.Y. 10036.
High Altitudes
For altitudes/elevations above 2,000 feet, input ratings should be
reduced at the rate of 4 percent for each 1,000 feet above sea level.
For Canadian high altitude applications, this appliance is suitable
for installation at elevations between 0 feet and 4,500 feet without
change
.
Piezo Pilot Ignitor Instructions
Depressing the red button completely causes a spark to occur at the
pilot. This is a substitute for a match which requires opening the
pilot hole cover.
To light the pilot, it is important that the electrode be 1/8" from the
thermocouple. The spark must occur at the point the burner flame
hits the thermocouple. The end of the electrode will be red hot with
the pilot on.
On a new installation with air in the gas line, it is suggested that a
match be used. The match will light the pilot faster than the piezo
under this condition.
Model
DVC-35SPP
DVC-35IP
Input BTU/HR
35,000
35,000
Height
72 1/2"
72 1/2"
Width
14 1/8"
14 1/8"
Depth
10 3/8"
10 3/8"
Gas Inlet
1/2" Pipe
1/2" Pipe
CFM
275
275
Accessories
SOR-1
Register, Side Outlet
SOK-1
Side Outlet Kit, 10" (25.4cm) Boot Assembly with Register
*DV-822
Vinyl Siding Vent Kit
* DV-822, Vinyl siding vent kit, adds 3" to wall depth. You must include the three (3) additional inches for
TOTAL
wall depth when
ordering a vent kit.
SPECIFICATIONS