background image

13281-9-0709

Page 19

PLEASE NOTE:  

When ordering parts, it is very important that  

part number

 and 

description

 of part coincide.

  USE ONLY MANUFACTURER'S REPLACEMENT PARTS.  USE OF ANY OTHER PARTS COULD CAUSE INjURY OR DEATH.

PARTS LIST

INDEX 

NO

PART NO DESCRIPTION

1

11762

OUTeR CaSING TOP

2

R-618

MOTOR MOUNT - 4 REQUIRED

3

11764

MOTOR MOUNTING BaR - 2 Re-

QUIRED

4

M-147

GASKET - 2 REQUIRED

5

R-619

MOTOR

6

11787

FaN BLaDe

7

11766

FaN HOUSING

8

DV-558

FRONT PaNeL-  UPPeR

9

11759

SIDe PaNeL

10

DV-613

INNeR SHIeLD - RIGHT

11

13057

OUTLeT TUBe - INNeR aSSeMBLY 

(INCLUDES 12 & 13)

12

M-177

GaSKeT - OUTLeT COLLaR

13

13104

OUTLeT TUBe - INNeR WeLDeD 

aSSeMBLY

14

13062

INLeT TUBe - INNeR aSSeMBLY 

(INCLUDES 15 & 16)

15

M-178

GaSKeT - INLeT COLLaR

16

13106

INLeT TUBe - INNeR WeLDeD aS-

SeMBLY

17

13064

INLeT TUBe - OUTeR aSSeMBLY

18

13059

OUTLeT TUBe - OUTeR aSSeMBLY

19

13053

VeNT CaP WeLDeD aSSeMBLY

20

13110

aIR DROP WeLDeD aSSeMBLY

21

M-176

GaSKeT - FLUe OUTLeT FLaNGe

22

13113

COMBUSTION CHaMBeR WeLDeD 

aSSeMBLY

23

R-1536

BUSHING

24

11765

SWITCH COMPaRTMeNT

25

R-630

LIMIT CONTROL

26

R-1941

FaN CONTROL

27

DV-832

SWITCH COMPaRTMeNT COVeR

28

DV-562

FRONT PaNeL - LOWeR

29

DV-826

ReaR BURNeR aSSeMBLY

30

R-1617

SPaRK PLUG WIRe

31

R-714-L

PILOT WITH ORIFICe - LPG GaS 

31

R-714-N

PILOT WITH ORIFICe - NaT GaS 

32

DV-808

PILOT TUBING

33

DV-824

FRONT BURNeR aSSeMBLY

34

P-88-41

ORIFICE - NAT GAS - 2 REQUIRED

34

P-88-53

ORIFICE - LPG GAS - 2 REQUIRED

35

DV-687

MaNIFOLD

36

M-148

GaSKeT - MaNIFOLD

37

M-155

GaSKeT-OBSeRVaTION HOLe 

COVeR

38

DV-781

LIGHTING HOLe COVeR aSSeMBLY

39

DV-064

COVeR PLaTe-OBSeRVaTION HOLe

40

DV-691

SeaL BRaCKeT

41

M-147

GaSKeT - TUBING SeaL

42

DV-847

BURNeR DOOR - NaT GaS 

42

DV-972

BURNeR DOOR - LPG GaS 

43

DV-779

GaSKeT - BURNeR DOOR

44

P-112

MaNIFOLD UNION

45

R-2147

GaS VaLVe - LPG GaS 

45

R-2149

GaS VaLVe - NaT GaS 

46

UH-810

TRaNSFORMeR MOUNTING BRaCK-

eT

47

R-1995

TRaNSFORMeR

48

UH-451

jUNCTION BOX COVER

49

11760

OUTeR CaSING BOTTOM

50

R-1515

BUSHING

51

R-690-B

CORD SeT

52

DV-571

CONTROL COMPaRTMeNT DIVIDeR

53

DV-671

MaNIFOLD SUPPORT

54

DV-765

GaSKeT - CHaMBeR aIR INLeT 

(TOP & BOTTOM) - 2 REQUIRED

55

DV-764

GaSKeT - CHaMBeR aIR INLeT 

(SIDES) - 2 REQUIRED

56

DV-692

MODULe MOUNTING BRaCKeT

57

R-721

WIRe HaRNeSS - CONTROL MOD-

ULe

58

R-1616

CONTROL MODULe

59

R-1404

BUSHING

60

DV-614

INNeR SHIeLD - LeFT

61

11759

SIDe PaNeL

NOT 

SHOWN

R-9832

WIRING aSSeMBLY UPPeR

NOT 

SHOWN

R-9833

WIRING aSSeMBLY LOWeR

NOT 

SHOWN

R-6389

THeRMOSTaT 

NOT 

SHOWN

R-734

LIGHTeR ROD 

INDEX 

NO

PART NO DESCRIPTION

Содержание DV-55IPT-1

Страница 1: ...ath or serious illness Installer Leave this manual with the appli ance Consumer Retain this manual for future refer ence Do not store or use gasoline or other flamma ble vapors and liquids in the vici...

Страница 2: ...6 Specifications 6 Gas Supply 7 8 Clearances 8 Installation Instructions 9 11 Lighting Instructions 12 Pilot Flame Characteristics 13 Main Burner Flame Characteristics 13 Wiring 14 Service and Mainte...

Страница 3: ...arandfreefromcombustible material gasoline and other flammable vapors and liquids Do examine venting system periodically and replace damaged parts Do make a periodic visual check of pilot and burners...

Страница 4: ...lights perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorptio...

Страница 5: ...torasrequiredinaccordance with the above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certified 3 SIGNAGE Ametalorplasticidentificationplateshallbe permanently mounted to t...

Страница 6: ...alled so that all burners and burner ignition devices are located not less than 18 above the floor Such equipment shall be located or protected so it is not subject to physical damage by a moving vehi...

Страница 7: ...ame to check for leaks Appliance must be disconnected from piping at inlet of control valve and pipe capped or plugged for pressure test Never pressure test with appliance connected control valve will...

Страница 8: ...t kits for wall depths of 8 to 12 or 12 to 19 The use of tubes not supplied by the manufacturer results in unsatisfactory performance 3 The DV 55IPT can be attached to the wall or recessed into the wa...

Страница 9: ...ide outlet kit 10 boot assembly with register SOK 1 for warm air discharge into an adjoining room may be installed on either side of the furnace at the required clearance of 4 inches to adjacent wall...

Страница 10: ...ntrol compartment bottom of the furnace Please remove 7 8 knockout from appropriate side panel when routing plug assembly to an electrical outlet Installation of Three prong Grounding Plug Assembly 1...

Страница 11: ...nlet and the flue outlet portions of the vent Any wall projection such as a door or window casing which disturbs the wind on one side of the air inlet section will result in back pressure on the flue...

Страница 12: ...ice technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water 1 Stop Read the safety information above 2 Set the thermostat to lo...

Страница 13: ...ilot flame and the spark gap are factory checked and tested After use cleaning may be required for the proper flame The correct flame will be a short blue inner flame with a much larger light blue out...

Страница 14: ...sed plugged into the ungrounded receptacle and its wire connected to the receptacle mounting screw With this wire completing the ground the appliance cord plug can be plugged into the adapter and be e...

Страница 15: ...switch type 24 Vac thermostats capable of supplying rated voltage and current to the module AMBIENT TEMPERATURE RATING Minus 40 F to plus 175 F minus 40 C to plus 79 C RELATIVE HUMIDITY RATING 5 to 9...

Страница 16: ...ALVE PILOT OPERATOR OPENS PILOT BURNER OPERATION PILOT BURNER LIGHTS MODULE SENSES FLAME CURRENT PILOT BURNER DOES NOT LIGHT OR MODULE RESPONSE S8600H AFTER90SECONDS PILOTVALVE CLOSES SPARKSTOPS LOCKO...

Страница 17: ...ion cable or other heavily insulated wire A Close the manual gas valve B Disconnect the ignition cable at the SPARK terminal on the module Warning Whenperformingthefollowingsteps donottouchstripped en...

Страница 18: ...orrect Check boot of the ignition cable for signs of melting or buckling Take protective action to shield cable and boot from excessive temperatures Check for 24 VAC across MV MV PV terminals If no vo...

Страница 19: ...NEL LOWER 29 DV 826 REAR BURNER ASSEMBLY 30 R 1617 SPARK PLUG WIRE 31 R 714 L PILOT WITH ORIFICE LPG GAS 31 R 714 N PILOT WITH ORIFICE NAT GAS 32 DV 808 PILOT TUBING 33 DV 824 FRONT BURNER ASSEMBLY 34...

Страница 20: ...13281 9 0709 Page 20 PARTS VIEW...

Страница 21: ...m Parts Heater Hearth and Grills Victor Division of F W Webb Company 200 Locust Street Hartford CT 06114 Phone 860 722 2433 Toll Free 800 243 9360 Fax 860 293 0479 Toll Free Fax 800 274 2004 Websites...

Страница 22: ...13281 9 0709 Page 22 SERVICE NOTES...

Страница 23: ...13281 9 0709 Page 23 SERVICE NOTES...

Страница 24: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Отзывы: