background image

12433-10-0109

Page 6

introduction

Always  consult  your  local  Building  Department  regarding 

regulations, codes or ordinances which apply to the installation of 

a direct vent wall furnace.
Instructions to Installer

1.  Installer  must  leave  instruction  manual  with  owner  after 

installation.

2.  Installer must have owner fill out and mail warranty card supplied 

with furnace.

3.  Installer should show owner how to start and operate furnace 

and thermostat.

Warning:

Any change to this furnace or its control can be dangerous.  This 

is a heating appliance and any panel, door or guard removed 

for servicing an appliance must be replaced prior to operating 

the appliance.

General information

This furnace is design certified in accordance with American National 

Standard/CSA Standard Z21.86 and CSA 2.32 by the Canadian 

Standards Association, as a Gravity Direct Vent Wall Furnace to be 

installed on an outside wall according to these instructions.
Any alteration of the original design, installed other than as shown 

in these instructions or use with a type of gas not shown on the 

rating plate is the responsibility of the person and company making 

the change.

important

All correspondence should refer to complete Model No., Serial 

No. and type of gas.
Notice

:  During initial firing of this unit, its paint will bake out  and 

smoke will occur.  To prevent triggering of smoke alarms, ventilate 

the room in which the unit is installed.

installation in residential Garages

Gas utilization equipment in residential garages shall be installed 

so that all burners and burner ignition devices are located not less 

than 18" (457mm) above the floor.

Such equipment shall be located, or protected, so it is not subject 

to physical damage by a moving vehicle. 

Qualified Installing Agency

Installation and replacement of gas piping, gas utilization equipment 

or  accessories  and  repair  and  servicing  of  equipment  shall  be 

performed only by a  qualified agency.  The term "qualified agency" 

means any individual, firm, corporation or company which either in 

person or through a representative is engaged in and is responsible 

for  (a)  the  installation  or  replacement  of  gas  piping  or  (b)  the 

connection, installation, repair or servicing of equipment, who is 

experienced in such work, familiar with all precautions required 

and has complied with all the requirements of the authority having 

jurisdiction.

state  of  Massachusetts

:  The  installation  must  be  made  by 

a  licensed  plumber  or  gas  fitter  in  the  Commonwealth  of 

Massachusetts.

The installation must conform with local codes or, in the absence of 

local codes, with the

 National Fuel Gas Code ANSI  Z223.1/NFPA 

54* Natural Gas and Propane Installation Code, CSA B149.1.

*Available from the American National Standards Institute, Inc., 11 West 42nd St., 
New York, N.Y. 10036. 

High altitudes

For altitudes/elevations above 2,000 feet (610m) , input ratings 

should be reduced at the rate of 4 percent for each 1,000 feet (305m) 

above sea level.  Canadian High Altitudes for locations having an 

elevation above mean sea level between 2,000 feet (610m) and 

4,500 feet (1370m), the manifold pressure is to be decreased from 

4.0" w.c. (.996kPa) to 3.2" w.c. (.797kPa) for Natural Gas and from 

10.0" w.c. (2.49kPa) to 8.0" w.c. (1.99kPa) for Propane Gas.

installation on rugs and tile

If this appliance is to be installed directly on carpeting, tile, or other 

combustible material, other than wood flooring, the appliance shall 

be installed on a metal or wood panel extending the full width and 

depth of the appliance.

The base referred to above does not mean the fire-proof base as 

used on wood stoves.  The protection is primarily for rugs that may 

be extremely thick and light-color tile that may discolor.

Model

DV-210

DV-215

Input BTU/HR (KW/H)

10,000 (2.9)

15,000 (4.4)

Height

21 3/8" (543mm)

24 7/8" (632mm)

Width

16 1/4 (413mm)

20 1/4" (514mm)

Depth

9 3/8" (239mm)

9 3/8" (239mm)

Gas Inlet

1/2" (13mm)

1/2" (13mm)

Options for Above Furnaces

Blower

DVB-1

DVB-1

Vinyl Siding Vent Kit

DV-822

DV-822

introDuction

sPeciFications

Содержание DV-210-SG

Страница 1: ...th or serious illness Installer Leave this manual with the appli ance Consumer Retain this manual for future refer ence Do not store or use gasoline or other flamma ble vapors and liquids in the vicin...

Страница 2: ...ifications 6 Gas Supply 7 Clearances 8 Installation Instructions 8 9 Thermostat Location 10 Lighting Instructions 11 Pilot Flame Characteristics 12 Main Burner Flame Characteristics 12 Maintenance 12...

Страница 3: ...ied service person More frequent cleaning may be required due to excessive lint from carpeting bedding materials etc It is impera tive that control compartments burners and circulating air passageways...

Страница 4: ...g vehicle trailer or area Finally let the service man and firefighters check for escaped gas Have them air out the area before you return Properly trained LP Gas service people should repair the leak...

Страница 5: ...uiredinaccordance with the above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certified 3 SIGNAGE Ametalorplasticidentificationplateshallbe permanently mounted to the exter...

Страница 6: ...erformed only by a qualified agency The term qualified agency meansanyindividual firm corporationorcompanywhicheitherin person or through a representative is engaged in and is responsible for a the in...

Страница 7: ...that a drip line be installed near the gas inlet This should consist of a vertical length of pipe tee connected into the gas line that is capped on the bottom in which condensation and foreign partic...

Страница 8: ...nimum wall depth is 4 1 2 114mm and maximum wall depth is 13 330mm The use of tubes not supplied by the manufacturer result in unsatisfactory performance The furnace is to be located on an outside wal...

Страница 9: ...l Remove 5 127mm diameter air inlet tube from collar of air drop assembly 2 Attach3 76mm diameterflueoutlettubeontoflueoutletcollar oncombustionchamber Besure3 76mm diameterflueoutlet tube is placed a...

Страница 10: ...d be Across the thermopile terminals 400 450 millivolts with ther mostat off Across the thermopile terminals 150 250 millivolts with ther mostat on Across the thermostat wires at the valve less than 3...

Страница 11: ...to desired setting 16 CAUTION Pilot access cover must be kept tightly closed during operation To Turn Off Gas To Appliance FOR YOUR SAFETY READ BEFORE LIGHTING Warning If you do not follow these inst...

Страница 12: ...ted After this the valve and orifice elbow can be removed as a unit Cleaning The Pilot Burner Cleaning of the pilot may be an annual necessity due to spiders After removing the supply tubing and orifi...

Страница 13: ...properly size orifice 4 Pilot and main burner go out during normal operation a Check millivolts b Check for proper size of pilot flame c Check for defective or weak thermopile d Check input reduce as...

Страница 14: ...HOLE 11 852098 NUT FOR ORIFICE FITTING 12 742134 BURNER ORIFICE DV 210 NAT 12 742133 BURNER ORIFICE DV 215 NAT 12 742297 BURNER ORIFICE DV 210 LPG 12 742282 BURNER ORIFICE DV 215 LPG 13 742038 ORIFICE...

Страница 15: ...12433 10 0109 Page 15 PARTS VIEW...

Страница 16: ...appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong re ceptacle Do not cut or remove th...

Страница 17: ...ms Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Отзывы: