IP TROUBLESHOOTING
Brief Description of the Components
The Digital Fireplace Control (DFC) is an automatic gas ignition
system based on a single micro-controller core. This control
manages all functions related to ignition, flame sensing and
supervision for atmospheric applications.
The DFC can be set to provide continuous or intermittent ignition
control sequences and flame monitoring with safety shutdown in
case of failure.
The DFC is set up as a stand alone (AC powered system with
battery back up. See IP Lighting Instructions on page 29 and
Wiring Diagram on page 44.
Troubleshooting
Before proceeding with the procedures in the following
troubleshooting table, verify that the power supply (AC/DC
adapter) is present and that the batteries inside the receiver
and/or optional battery pack are fresh and installed with correct
polarity.
Make sure all the connections between the wire harnesses and
system components are proper and positive.
Verify that the static inlet pressure meets the manufacturer’s
recommended inlet pressure. If necessary adjust the line
pressure regulator.
If the recommended actions for the following troubleshooting
chart do not help to address the problem consider replacing
wiring harnesses.
WARNING
Any actions performed on the gas valve must be performed in
accordance with this instruction manual. Likewise, any actions
performed on the DFC or other system components must be
done in accordance with the individual component instructions.
Replacement of components must be performed in accordance
with this instructions manual.