34846-2-1016
Page 18
3. Lift the complete burner and valve assembly upward, then
turn it sideways in fireplace opening to gain easy access
to the junction box.
See Figure 19.
You may remove the
complete burner and valve assembly as shown in
Figure 19.
Figure 19
4 The junction box is located on the right side of the fireplace.
Remove the two 5/16” Hex screws that secure the junction
box to the firebox, and remove the junction box.
See
Figure 20.
Run romex wire through the right rear corner of
the fireplace and into the firebox area. Secure wiring with
the romex connector as required and install the duplex
receptacle as shown in
Figure 21
. Attach the black wire to
the brass screw side of the receptacle, and the white wire to
the opposite side. Secure the incoming ground wire under
the green ground screw provided on the receptacle.
Figure 20
Figure 21
5. If only installing the LK5 Accent Light kit, then remove the
7/8” diameter knockout in the back of the junction box, install
the 7/8” diameter protective grommet, and connect the wiring
with wire nuts as shown in
Figure 21.
There is a solid junction box cover plate included with
the LK5 kit that should be used on the junction box if a
duplex receptacle is not used.
6. Once the junction box wiring is completed, re-install the
junction box into the lower right corner of the firebox cavity
using the screws removed in step 4 as shown in
Figure 22.
Figure 22
7. Reinstall the burner and valve assembly and reattach the
screws removed in step 2.
See Figure 14.
8. For VFLL(38,48)FP90: Reconnect the wire from the switch
on the heat shield and put the shield back in place.
JUNCTION BOX WIRINg INSTALLATION