34846-2-1016
Page 32
Flames from the pilot (front center of burner) as well as the main
flame should be visually checked as the fireplace is installed.
In normal operation at full rate after 10 to 15 minutes, the flame
appearance should be sets of yellow flames.
NOTICE
:
All flames will be random by design, flame height will
go up and down.
Avoid any drafts that alter burner flame patterns. Do not allow
fans to blow directly into fireplace. Do not place a blower inside
the burner area of the firebox. Ceiling fans may create drafts that
alter flame patterns. Sooting and improper burning will result.
During manufacturing, fabricating and shipping, various
components of this fireplace are treated with certain oils, films
or bonding agents. These chemicals are not harmful, but may
produce annoying smoke and smells as they are burned off
during the initial operation of the fireplace, possibly causing
headaches or eye or lung irritation. This is a normal and
temporary occurrence.
The initial break-in operation should last 2-3 hours with the
burner at the highest setting. Provide maximum ventilation by
opening windows or doors to allow odors to dissipate. Any odors
remaining after this initial break-in will be slight and will disappear
with continued use.
Once the break in operation has been completed, adjust the
fireplace to the desired output and then replace the surround.
OPERATION INSTRUCTIONS/FLAME APPEARANCE
Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.
Millivolt thermopile is self powered, gas valve does not require
110 volts. Maximum length of 20 feet of 16 AWG to conductor
wires is to be used with all optional switches.
Check 750 Millivolt System Operation
Millivolt system and all individual components may be checked
with a millivolt meter 0-1000 MV range. The thermopile reading
needs to be between 325 and 400 millivolts.
Remote Receiver
Use the following steps to place the remote receiver adjacent to
the gas valve.
Attention:
The remote receiver bracket is not used in this
installation.
1. The remote receiver can not be placed beside the gas valve
and burner assembly.
2. When facing the fireplace, the remote receiver must be
placed to the left of the gas valve.
Refer to remote control installation and operating instructions for
more details on remote control.
Figure 53
H
N
REMOTE CONTROL RECEIVER/
THERMOSTAT/CONTROLE E
DISTANCE DU RECEPTEUR
GAS VALVE
VALVE DE GAZ
(OPTIONAL) REMOTE/OFF/ON SWITCH
A DISTANCE/OUVERT/
FERME INTERRUPTEUR (FACULATIVE)
IF ANY OF THE ORIGINAL WIRE
AS SUPPLIED WITH THIS UNIT
MUST BE REPLACED, IT MUST BE
REPLACED WITH NUMBER 18, 150 C
WIRE OR ITS EQUIVALENT.
o
SI UN DES FILS ELECTRIQUES
ORIGINAUX, VENANT DU FABRICANT
AVEC CETTE UNITE, DOIT ETRE
REMPLACE, VOUS DEVEZ LE
REMPLACER AVEC UN FIL
ELECTRIQUE DE NUMERO 18,
150 C DU L’EQUIVALENT.
o
WIRING DIAGRAM
REMOTE CONTROL RECEIVER
(FACULTATIVE) CONTROLE E DISTANCE
DU RECEPTEUR
(OPTIONAL) WALL SWITCH
INTERRUPTEUR MURAL
(FACULTATIVE)
(OPTIONAL) THERMOSTAT
(FACULATIVE) THERMOSTAT
GAS VALVE
THERMOCOUPLE
(NATURAL)
THERMOCOUPLE
(LPG)
PILOT
VEILLEUSE
THERMOPILE
PRESSURE TAP
MILLIVOLT WIRING