37795-3-0119
Page 11
Side Wall clearances
The clearance from the edge of the glass bed in the firepit to any
combustible wall should not be less than 3-1/4 inches.
NOTICE:
For installations with a rear wall and side wall, refer to
Figures 6 and 9.
NOTICE:
See pages 9 and 10 for additional wall and ceiling
clearances to combustibles.
Minimum ceiling clearances
Ceiling Clearances: The ceiling height should not be less than
48 inches from the top surface of the firepit.
Rear Wall clearances
The clearance from the edge of the glass bed in the firepit to any
combustible rear wall should not be less than 12 inches.
caUTiOn
Vinyl siding must not be installed within 24 inches of the
edge of the glass bed in the firepit.
planninG inSTallaTiOn (cOnT'D)
No greeting cards, stockings or ornamentation of any type should
be placed over the firepit. This is an open flame appliance. The flow
of heat and flames can ignite combustibles.
No
vinyl siding materials can be installed within 24 inches of the
crushed glass area on the firepit.
REAR
SIDE
SIDE
3-wall alcove not allowed.
Figure 13
REAR
SIDE
SIDE
CEILING
3-wall alcove with ceiling not allowed.
Figure 14
CLEARANCES
COMBUSTIBLE MATERIALS
0” TO FRONT
AND REAR SIDES
0” TO BOTTOM
0” TO
LEFT AND
RIGHT SIDES
COMBUSTIBLE CLEARANCE REQUIREMENTS
Figure 12
COMBUSTIBLE CLEARANCE REQUIREMENTS