43115-2-0821
43115-2-0821
Page 8
Special Venting Components (Duravent)
See Empire Comfort Systems Retail Price List
for Duravent part numbers and pricing.
SPECIAL DV VENT KITS
Available from Empire Comfort Systems, Inc. dealers
DVVK-4FV
Vertical Flex Vent Kit 4" x 7"
DVVK-4VP
Direct-Vent Fireplace Vent Kit - Vertical,
Includes SD-991, SD-953, and SD-943
DVVK-4TP
Direct-Vent Fireplace Vent Kit for Top Vent,
Thru-the-wall, 8 to 11 inch wall thickness,
Includes SD-911, SD-985, SD-990 and SD-942
DVVK-4RP
Direct-Vent Fireplace Vent Kit for Rear Vent, 5
to 7 inch wall thickness, (standard thru-the-wall
venting) Includes SD-908, SD-985 and SD-942
DVVK-4RE
Direct-Vent Fireplace Vent Kit for Rear Vent,
Thru-the wall, 5 to 13
3
/
4
inch wall thickness,
(standard thru-the-wall venting) Includes SD-
908, SD985 and SD-942
DVVK-4TSP
Direct-Vent Fireplace Vent Kit for Top Vent,
Thru-the-wall, 5 to 7 inch wall thickness,
Includes SD-908, SD-985, SD-990 and SD-942
VIB6A
Vertical Inlet Baffle Kit for 6
5
/
8
inch diameter.
VIB7A
Vertical Inlet Baffle Kit for 7 inch diameter.
VENT SYSTEM IDENTIFICATION
Begin the vent system installation by selecting the type of venting
to be installed and the path that it will take. Verify that clearances
are met throughout the path of the venting system. Determine if the
fireplace is to be vented out the top or out the rear.
NOTICE:
Some fireplaces cannot be vented out the rear of the fireplace.
Determine how the vent system will be terminated out the side of
the house or through the roof. Verify clearances for the termination.
When selecting a vent system for use with the fireplace, refer to the
“Special Vent Systems” section in this manual to determine what
systems are acceptable.
Check all clearances and venting components. Identify if any
problems existing in the vent system. Use Figure 22, page 18 for
top venting or Figure 32, page 22 for rear venting to eliminate issues
after installation. Check pipe diameter on vent system and fireplace
to verify the size is the same.
NOTICE:
All outer connection joints must be sealed with
aluminum tape, screws or silicone sealant rated above
300°F/149°C. The inner flue joints do not require any sealant.
Figure 1
•
Duravent® Pro 4" - 6 ⅝"
•
American Metal Products 4" - 6 ⅝"
•
Selkirk Direct-Temp® 4" - 6 ⅝"
•
MetalFab SureSeal® 4" - 6 ⅝"
•
BDM 4”
•
Security Secure Vent® 4" - 6 ⅝"
SPECIAL VENT SYSTEMS
•
Excel DV 4" - 6 ⅝"
•
Olympia VENTIS®
•
Empire Horizontal Round Termination Kit
DVVK-4RE,
DVVK-4REVS
Empire Flexvent Kits:
•
DVVK-4F, DVVK-4FV, DVVK-4FRE, DVVK-4FREVS
THE FOLLOWING VENT SYSTEMS ARE ACCEPTABLE FOR USE WITH THE DVD (32, 36, 42, 48) SERIES FIREPLACES:
Содержание MILLIVOLT DVD32FP30N-3
Страница 21: ...Page 21 43115 2 0821 Figure 31 EXAMPLES TOP VENT RUN Figure 30 Figure 29...
Страница 41: ...Page 41 43115 2 0821 MILLIVOLT STANDING PILOT WIRING DIAGRAM FP3 SERIES Figure 61...
Страница 47: ...Page 47 43115 2 0821 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING FP7 SERIES...
Страница 48: ...43115 2 0821 Page 48 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING FP7 SERIES...
Страница 65: ...Page 65 43115 2 0821 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...