FRAMING AND FINISHING
Installing Support Brackets
A horizontal pipe support MUST BE used for each 3 feet of horizontal
run. The pipe supports should be placed around the pipe and nailed
in place to framing members. There MUST BE a 3 inch clearance
to combustibles above 6-5/8 inch diameter pipe and elbows and
1 inch clearance on both sides and bottom of 6-5/8 inch pipe to
combustibles on all horizontal pipe sections and elbows.
Vertical runs of this vent systems must be supported every 4 feet
above the appliance flue outlet by wall brackets attached to the
6-5/8 inch vent pipe and secured with nails or screws to structural
framing members.
Figure 38
Installing Firestops
Firestops are required for safety whenever the vent system passes
through an interior wall, an exterior wall, or a ceiling. These firestops
act as a firebreak heat shield and as a means to insure that minimum
clearances are maintained to the vent system.
Horizontal Firestops
Horizontal runs in the vent system which pass through either interior
or exterior walls, require the use of wall firestops on both sides of
the wall through which the vent passes.
Position the firestops on both sides of the framed hole, previously
cut. Refer to
Figure 26
on page 20 for sizing information. Secure
firestop with nails or screws. The heat shields of the firestops
MUST BE placed towards the top of the hole. Continue the vent
run through the firestops.
11”
(297 mm)
MIN.
9 1/8”
(232 mm)
MIN.
OUTSIDE THIMBLE ASSEMBLY
INSIDE THIMBLE ASSEMBLY
EXTERIOR
SHEAVING
Figure 39
Содержание MILLIVOLT DVD32FP30N-3
Страница 21: ...Page 21 43115 2 0821 Figure 31 EXAMPLES TOP VENT RUN Figure 30 Figure 29...
Страница 41: ...Page 41 43115 2 0821 MILLIVOLT STANDING PILOT WIRING DIAGRAM FP3 SERIES Figure 61...
Страница 47: ...Page 47 43115 2 0821 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING FP7 SERIES...
Страница 48: ...43115 2 0821 Page 48 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING FP7 SERIES...
Страница 65: ...Page 65 43115 2 0821 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...