Important: 

• 

This appliance should be serviced every 12 months, 
preferably at the start of each heating season. More 
frequent inspection may be required if the fireplace is 
installed in an area exposed to pet hair or dust, or to 
excessive lint from new carpeting or bedding materials. 

• 

Any service operation should be carried out only by a 
suitably qualified and trained person. 

• 

This manual should be left with the appliance for future 
reference. 

• 

DO NOT MODIFY THIS APPLIANCE.

NOTICE:

 It is normal for steel appliances to make expansion/ 

contraction noises as they heat up or cool down. Similar noises are 
found with your furnace or car engine. 

It is normal for your gas fireplace to give off some odor the first 
time it is burned. This is due to the curing of the paint and any oil 
from the manufacturing process. If odor becomes offensive, open 
windows. 

Burn the fireplace for at least six hours the first time you use it. 
Keep the fan in the “OFF” mode during this time. 

NOTICE: 

Turn off the gas before servicing appliance. 

During the annual checkup, the technician will:
• 

I

nspect the pilot (flame safety system) and burner(s) for 

proper operation and replace any damaged parts. 

• 

Check the glass and gasket for proper seal. 

• 

Vacuum and clean any foreign debris in the firebox that is 
not supposed to be there. 

• 

Clean Glass with a suitable fireplace glass cleaner. Abrasive 
cleaners must not be used. Be careful not to scratch the 
glass when cleaning. 

• 

Check the barrier screen for fit and structural integrity. 

• 

Check all latches or other door retention components for 
proper operation, tension, and relief mechanisms are free 
from obstructions. 

• 

Inspect the log set (if applicable) and decorative media (if 
applicable) for debris or damage. 

• 

Freshen up the glowing embers if applicable. 

• 

Replace batteries in the remote transmitter and receiver 
if applicable. 

• 

Inspect the venting and vent termination cap for damage, 
corrosion, sooting, or obstruction and correct if present. 

• 

In addition, clean and inspect the fireplace following any 
remodeling work in your home.

MAINTENANCE AND SERVICE

Annual Service Procedure: 

Have a qualified service person perform the following 
(inspections) at the beginning of each heating season: 

• 

Check Vent System

 

Inspect the fireplace and venting system before initial use 
and at least annually. Inspect the external vent cap on a 
regular basis to make sure no debris is interferes with the 
air flow.

• 

Clean Burner and Control Compartment

 

Keep the control compartment, logs, and burner areas 
surrounding the logs clean by vacuuming or brushing at 
least twice a year. 

Cleaning Procedure

1. 

Turn off pilot flame using your remote. Allow the fireplace 
to cool completely.

2. 

Remove outer barrier screen and inner glass. 

3. 

Remove all logs and coals. Place them in a safe location.

4. 

Vacuum burner compartment.

5. 

Replace glowing embers, logs, and coals.

6. 

Clean the glass periodically. 

7. 

Clean any dust off the barrier screen periodically.

8. 

Re-install inner glass and outer barrier screen.

9. 

Ignite pilot.  

10.  Operate the pilot burner. If it appears abnormal contact 

your dealer for service. 

Содержание DVLXB55BP90N-1

Страница 1: ...plier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier This applianc...

Страница 2: ...lation 23 Vent Framing and Finishing 27 Venting Fireplace 33 Vent System Identification Vertical 34 Vent System Identification Horizontal 35 Decorative Crushed Glass Placement 37 LOG Placement 38 Ligh...

Страница 3: ...no blockage or restriction leakage corrosion and other deficiencies which could cause an unsafe condition 3 As far as practical close all building doors and windows and all doors between the space in...

Страница 4: ...cable Inspect the venting and vent termination cap for damage corrosion sooting or obstruction and correct if present Check all accessible gas carrying tubes connections pipes and other components for...

Страница 5: ...RTANT SAFETY INFORMATION DO NOT put anything around the fireplace that will obstruct the flow of ventilation air DO NOT use this fireplace if any part has been under water Immediately call a qualified...

Страница 6: ...ls and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity SAFETY INFORMATION FOR USERS OF PROPANE GAS Propane gas may stratify in a closed area and the odo...

Страница 7: ...be ANSI UL 2034 listed and IAS certified 3 SIGNAGE A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight feet above grade di...

Страница 8: ...agency The term qualified agency means any individual firm corporation or company which either in person or through a representative is engaged in and is responsible for a the installation or replace...

Страница 9: ...performed Leak check performed and inlet pressure verified FINISHING Verified all clearances meet installation manual requirements Mantels and wall projections meet requirements pg 11 Granite or Clea...

Страница 10: ...ng their products near a heat source If you install a television above this fireplace Empire Comfort Systems accepts no responsibility for damage or injuries Follow the television manufacturer s insta...

Страница 11: ...ted 4 Install the venting See page 27 to page 36 5 Install and connect the gas lines See page 20 and page 21 6 Install the wiring See page 22 7 Remove the barrier assemblies See page 57 to page 59 8 I...

Страница 12: ...12 CARTON CONTENTS AND HARDWARE PACK 1 2 3 Index Number Description Part Number Quantity Supplied 1 Product Registration Card 1 2 LED Remote ESC838024 1 3 SIT Remote Transmitter ESC838004 1...

Страница 13: ...nter 2 3mm 1 2mm Orifice Sides 1 95mm 1 05mm Air Shutter Opening Center Burner Fully Closed Fully Open Air Shutter Opening Side Burners Fully Closed Fully Open Gas Inlet Shut Off Valve Pipe 1 2 in BSP...

Страница 14: ...box not shown 10 23 32 G Depth from front trim to centerline of exhaust vent 7 21 32 H Depth from back of the box to centerline of exhaust vent 7 15 32 I Height from bottom of the box to centerline of...

Страница 15: ...box not shown 10 23 32 G Depth from front trim to centerline of exhaust vent 7 21 32 H Depth from back of the box to centerline of exhaust vent 7 21 32 I Height from bottom of the box to centerline of...

Страница 16: ...on NOTICE When installing this fireplace against an exterior wall insulate to applicable insulation codes Single Sided ONLY LOCATING FIREPLACE DVLXB55B Single Sided DVLXB55S Double Sided A peninsula r...

Страница 17: ...pipe Side Wall and Ceiling The minimum clearance from the floor to the ceiling is 36 inches The minimum clearance from the side of the fireplace opening to an adjacent sidewall is 6 inches MIN 36 915...

Страница 18: ...ENDICULAR SIDE WALL BALCONY WITH NO SIDE WALL G G COMBUSTIBLE 9 229mm NONCOMBUSTIBLE 2 51mm H COMBUSTIBLE 18 457mm NONCOMBUSTIBLE 12 305mm H I COMBUSTIBLE 18 457mm NONCOMBUSTIBLE 12 305mm I E D C E C...

Страница 19: ...W 12 in 30 cm for appliances 10 000 Btuh 3 kW and 100 000 Btuh 30 kW 36 in 91 cm for appliances 100 000 Btuh 30 kW 6 in 15 cm for appliances 10 000 Btuh 3 kW 9 in 23 cm for appliances 10 000 Btuh 3 kW...

Страница 20: ...a New Main Gas Shut Off Valve Check Local Code Each fireplace should have its own manual gas shut off valve A manual main gas shut off valve should be located in the vicinity of the fireplace Where no...

Страница 21: ...CONT D Test For Leaks On Unexposed Connections Perform a pressure test on all unexposed connections Never pressure test with fireplace connected control valve will sustain damage Disconnect the firep...

Страница 22: ...tion switch which is accessible from outside the cavity can also be used to disconnect the power Regardless of the method used it MUST ALWAYS be possible to safely isolate the electrical supply to the...

Страница 23: ...ace and or its vent system In cooler climates the vent should be enclosed inside the chase NOTICE Requirements for ceiling and wall shield firestops and construction of the chase may vary with the typ...

Страница 24: ...setting the depth of the fireplace NOTE MIN Clearances for gas connection and exhaust venting 3 Install nailing flanges onto fireplace 4 Move fireplace into position 5 Secure fireplace to framing with...

Страница 25: ...ATTENTION Cold climate installation recommendation When installing this fireplace against a non insulated exterior wall it is recommended that the outer walls be insulated to conform to applicable in...

Страница 26: ...TION CONT D Corner Installation Vertical 90 degree elbow to 45 degree horizontal out the wall 12 in minimum rise before elbow NOTICE Corner installation will require more vertical vent pipe depending...

Страница 27: ...RAMING AND FINISHING Installing Firestops Firestops are required for safety whenever the vent system passes through an interior wall an exterior wall or a ceiling These firestops act as a firebreak he...

Страница 28: ...ctions Cut a 10 5 8 inch x 10 5 8 inch hole through the ceiling using the center point previously marked Frame the hole with framing lumber the same size as the ceiling joists If the area above the ce...

Страница 29: ...es with the National Electrical Code ANSI NFPA 70 Latest Edition The supplied conduit and wires are common across other Empire models The pressure switch wires are not required for this model On the V...

Страница 30: ...tching 120VAC MAINS SUPPLY IN VENT FAN OUT Remove 6 Screws Insert the straight side of the main harness through the 7 8 inch hole in the rear panel of the Power Vent and secure with nut Connect the bl...

Страница 31: ...ly a bead of silicone sealant to the rear surface of the flange to create a weather tight seal between the mounting flange and the wall 14 1 2 2 1 9 Remove 6 screws GASKET HORIZONTAL FASCIA NOTE Seala...

Страница 32: ...Kit is required NOTICE This Power Vent cannot be vented out the rear of the fireplace NOTICE This Power Vent can only be used with DuraVent Direct Vent Pro 4 X 6 5 8 inch piping NOTICE All outer conne...

Страница 33: ...ows Effective Length 36 ft 5in H1 H2 H3 V1 A TO BOTTOM UNIT VENTING FIREPLACE EXAMPLE 2 Fireplace Height V1 H1 H2 Elbows Total Effective Length 3ft 5inch 5ft 10ft 20ft 2 36ft 5in Vertical Run Up Firep...

Страница 34: ...Verify clearances for the termination When selecting a vent system for use with the fireplace refer to the see Empire Comfort Systems Retail Price List for Simpson Duravent part numbers and pricing C...

Страница 35: ...clearances for the termination When selecting a vent system for use with the fireplace refer to the see Empire Comfort Systems Retail Price List for Simpson Duravent part numbers and pricing Check al...

Страница 36: ...ng In these cases increasing the vent height may solve this problem Installing the Vent System in a Chase A chase is a vertical box like structure built to enclose the gas fireplace and or its vent sy...

Страница 37: ...h crushed glass to mask the burner and infill excessive glass can cause sooting Ensure that the glass covers the entire infill and all the burners Notice Do not place crushed glass in the recessed pil...

Страница 38: ...H EMBERS 1248 CENTER LOG TOP CENTER LOG FRONT LARGE LOG 1 FRONT LARGE LOG 1 TOP TUNNEL LOG FRONT TUNNEL LOG TOP LARGE LOG 2 FRONT SMALL LOG FRONT SMALL LOG TOP EMBERS FRONT EMBERS TOP LARGE LOG 2 TOP...

Страница 39: ...it Fold all the log locating tabs up 90 as seen in the images below Place all logs as shown in the three steps on the next page Place the embers around the logs in a single layer Ensure that the ember...

Страница 40: ...CONT D Step 1 Step 2 Step 3 Completed Log Set with Bed of Embers Small Log Tunnel Log Tunnel Log Small Log Center Log Large Log 2 Large Log 1 Large Log 1 Medium Log 1 Medium Log 2 Medium Log 2 Large L...

Страница 41: ...en smell for gas including near the floor If you smell gas STOP Follow B in the safety information above on this page If you do not smell gas go to the next step 5 Turn ON electric power to the applia...

Страница 42: ...use severe injury or death The receiver causes ignition of the fireplace The fireplace can turn on suddenly Keep away from the fireplace burner when operating the remote system or activating manual by...

Страница 43: ...Push the ON button on the transmitter within 10 seconds The SIT controller will beep four times to indicate that the transmitter s command is accepted The system is now initialized Should the SIT cont...

Страница 44: ...m the receiver confirms reception of the command ure ture Remote Flame Control The fireplace has six flame levels With the system on and the flame level at the maximum in the fireplace pressing the do...

Страница 45: ...ns until the desired set temperature is displayed on the LCD screen of the transmitter Room Temperature Set Temperature MULTIFUNCTION REMOTE OPERATING INSTRUCTIONS Smart Thermostat Transmitter Operati...

Страница 46: ...function press the MODE and UP Buttons at the same time To deactivate this function press the MODE and UP Buttons at the same time Low Battery Power Detection Transmitter The life span of the remote c...

Страница 47: ...gized 2 A diagnostic code is sent through the diagnostic red LED and 3 The IFC board will ignore any burner ignition command and remain in the OFF state unless the unlock command sequence is met The c...

Страница 48: ...te touch the On Off key until the LEDs turn on and off The new remote is now paired Indicator Light Remote Pairing Button LED REMOTE OPERATING INSTRUCTIONS Speed Saturation Scene Mode Color Wheel Brig...

Страница 49: ...ht Adjust brightness short press 10 levels long press 1 5s for continuous 256 levels of brighness adjustment R G B Short press get red green or blue color directly long press 1 5s adjust R G B brightn...

Страница 50: ...ram on page 58 and Lighting Instructions on page 45 Troubleshooting Before proceeding with the troubleshooting table verify that the 120VAC power supply is present Make sure all the connections betwee...

Страница 51: ...sensor and pilot igniter Pilot not grounded well Check ground connections Sensor wire loose Check sensor wire terminals Gas pressure incorrect Adjust gas pressure Pilot gas line bent or kinked Replace...

Страница 52: ...Clogged or dirty burner ports Clean burner ports Faulty valve Replace valve High altitude Adjust orifice size for altitude Backfire of burner Blocked orifice Check orifice opening Clogged or dirty bu...

Страница 53: ...Installation and service must be performed by a qualified installer service agency or the gas supplier IPI ELECTRONIC SYSTEM WIRING DIAGRAM FUSE 5X20 FUSE MAINS SUPPLY CONNECTION LIVE 120VAC NEUTRAL G...

Страница 54: ...G55B DVLXG55S DVLXB55B DVLXB55S SIT Proflame II CKZ02 Propane to Natural MF DVLXG55B DVLXG55S DVLXB55B DVLXB55S SIT Proflame II Log Sets Description LS55LTF Log Set Ceramic Fiber Traditional Charred L...

Страница 55: ...035 Replacement Exhaust Thermal Cut Out TBC 14 ESC838038 Barrier Screen Assembly 15 ESC838036 Primary Glass Retainer 16 ESC838008 Room Fan Assembly Capacitor 17 ESC838017 Bottom Trim 18 ESC808021 Repl...

Страница 56: ...TS VIEW Inner Glass Primary 20 5 4 5 10 22 21 9 13 6 12 15 1 2 3 11 7 8 17 14 16 18 19 WARNING Failure to use parts specifically approved for this appliance may result in property damage or personal i...

Страница 57: ...Check the barrier screen for fit and structural integrity Check all latches or other door retention components for proper operation tension and relief mechanisms are free from obstructions Inspect the...

Страница 58: ...d service person replace damaged glass and gasket using materials specified by Empire Comfort Systems 3 Do not abuse or strike the glass 4 The use of substitute glass will void all product warranties...

Страница 59: ...gas valve it will result in a hazardous condition GAS VALVE INLET PRESSURE TAP OUTLET PRESSURE TAP Replacing a Remote Control If the wireless control becomes lost or damaged a new one can be ordered f...

Страница 60: ...the fireplace and rest it on the base Then disconnect the electrical connections to allow the fan tray to be removed entirely Replacing the Fan Thermal Cut Out TCO 60 C 140o F With the glass infill bu...

Страница 61: ...ace the pressure switch and reattach the screws and silicone tubes The black hose should be connected to the low pressure port and the translucent to the high pressure port For the Exhaust TCO Reach i...

Страница 62: ...62 MAINTENANCE AND SERVICE...

Страница 63: ...rvice person or dealer When ordering parts first obtain the Model Number and Serial Number from the rating plate on your equipment Then determine the Part Number from the list in this manual not the I...

Страница 64: ...will repair or replace at Empire s option Duties of the Owner The appliance must be installed by a qualified installer and operated in accordance with the instructions furnished with the appliance A...

Страница 65: ...65 Date Dealer Name Service Technician Name Service Performed Notes APPLIANCE SERVICE HISTORY...

Страница 66: ...fort Systems Inc Belleville IL If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question please contact your dealer www empi...

Отзывы: