53
If any of the original wire as supplied with this unit must be replaced, it
must be replaced with equivalent gauge and temperature rated wire.
This appliance is only for use with the type of gas indicated on the rating
plate and may be installed in an aftermarket, permanently located,
manufactured (mobile) home where not prohibited by local codes. This
appliance is not convertible for use with other gases, unless a certified kit
is used.
CAUTION
Do not operate the appliance with liner panel(s) removed, or
damaged. Replacement of the liner panel(s) should be done by a
licensed or qualified service person.
WARNING
Improper installation, adjustment, alteration, service or
maintenance can cause property damage, personal injury or loss
of life. Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
IPI ELECTRONIC SYSTEM WIRING DIAGRAM
FUSE
5X20
FUSE
MAINS
SUPPLY
CONNECTION
LIVE (120VAC)
NEUTRAL
GROUND
COMBUSTION FAN
COMFORT FANS
RUN INTERUPT (GREEN)
GREEN
PURPLE
GREEN
YELLOW
BELLEVILLE, ILLINOIS
DVLXB SERIES
620531_1
WHITE
BLACK
BLACK
BLACK
REMOTE “LEARN” (BLACK)
24VDC 40W POWER SUPPLY
+
─
4A 250V FUSE
(BAYONET
HOUSING)
PILOT
PRESSURE
SWITCH
BLACK
WHITE
BLACK (
COMBUSTION
FA
N)
RED
(COMFORT
FA
NS)
NON
-ST
ANDARD
SIT
PROFLAME
2
0.584.30
9
DO NOT REPLACE SIT
CONTROLLER WITH ANY OTHER
PROFLAME 2 VARIANT
50
Ω
284°F (140°C) VENT OUTLET
140°F (60°C) LH ROOM FAN
THERMAL CUTOUTS (NC)
GREEN/YELLOW
RED
GREEN
SMALL TERMINAL (SPARK)
GREEN/YELLOW
LARGE TERMINAL
GREEN/YELLOW
BLACK
RED
LED DRIVER
FIREBOX LED
6µF
RUN INTERUPT (GREEN)
(NC)
(NO)
CAUTION
Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.