17
Clearance to Combustibles
Back
ZERO
Side
ZERO
Floor
ZERO
Top Stand-Off Bracket
ZERO
Top Framing Edge
ZERO
NOTE: COMBUSTIBLE MATERIALS ALLOWED IN SHADED AREA
Vent Pipe Clearance
NOTICE
: Horizontal vent, maintain a minimum 1-inch clearance
to the bottom and sides of the vent, and
1-inch
minimum
clearance to combustibles above the vent pipe.
Side Wall and Ceiling
The minimum clearance from the floor to the ceiling is 36 inches.
The minimum clearance from the side of the fireplace opening to
an adjacent sidewall is 6 inches.
MIN. 36” (91
5 mm)
MIN. 6” (153
mm)
CLEARANCES
Mantel and TV Clearances
The minimum mantel and TV clearances are shown in the
diagrams below.
40°
9”
COMBUSTIBLE MANTELS &
TVs CAN BE INSTALLED
ANYWHERE IN THIS ZONE
TOP EDGE OF
FIREPLACE OPENING
A
B
C
D
E
F
G
1” Minimum
8”
MANTEL
Depth
Height
A
11 3/4”
14”
B
10 3/4”
13”
C
10”
12”
D
9 1/4”
11”
E
8 1/2”
10”
F
7 1/2”
9”
G
7”
8”