FINISHING METHODS
FINISHING METHOD 1:
•
Combustible wall sheathing (e.g. drywall) may be brought up
against the sides and top of the fireplace.
•
Framing brackets installed in 1/2-inch set-back position.
NON-COMBUSTIBLE FINISHING
MATERIAL OVERLAPPING FIRE-
PLACE FACE
COMBUSTIBLE WALL SHEATHING -
MAY BE BROUGHT AGAINST
SIDES AND TOP OF FIREPLACE
Figure 31
FINISHING METHOD 2:
•
Non-combustible wall sheathing overlaps the fireplace face.
•
Framing brackets installed in forward flush-with-face position.
NON-COMBUSTIBLE WALL SHEATHING
(NOT INCLUDED) OVERLAPS FIREPLACE FACE
NON-COMBUSTIBLE WALL SHEATHING
(NOT INCLUDED) OVERLAPS FIREPLACE FACE
Figure 32
Use Non-Combustible materials where indicated for the fireplace installation. Non-combustible materials do not ignite or burn as a result of
using the fireplace. These include metal, brick, ceramic, concrete, slate, glass and plaster. Adhesives must be rated for high temperatures.
Any mechanical fasteners used to install material must also be non-combustible, including wall anchors and tile spacers. Materials that pass
the ASTM E 136 test (Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750C) are considered non-combustible.
NON-COMBUSTIBLE
FINISHING MATERIAL
OVERLAPPING
FIREPLACE FACE
NON-COMBUSTIBLE
WALL SHEATHING (NOT
INCLUDED) OVERLAPS
FIREPLACE FACE