GETTING STARTED
WIRELESS SENSOR
1. Remove the battery door.
2. Insert 2 x AA size batteries into the battery compartment. Make sure you insert
them the right way according to the polarity information marked on the battery
compartment.
3. Close the battery door.
Note:
- This wireless sensor can receive the Radio controlled clock signal for main unit auto
time setting. Just pair up the sensor with main unit to apply this function.
- Once the channel is assigned to a Wireless Hygro-Thermo sensor, you can only
change it by removing the batteries or resetting the unit.
- Avoid placing the sensor in direct sunlight, rain or snow.
MAIN UNIT
1. Plug the power adapter to power up the main unit.
2. Once the main unit power up, it will enter normal time mode.
Note:
- You can using AAA batteries for backup purpose, remove the battery door and
install 3 new AAA size batteries as per the polarity information marked on the battery
compartment, then close the battery door.
- If no display appears on the LCD after installing the batteries, press the
[ RESET ]
key
by using a metal wire.
- To avoid the wireless sensor and main unit pairing fail, please power up the sensor(s)
[ RESET ]
key in main unit after sensor setup.
- You may not receive the signal immediately. Due to the atmospheric disturbance, the
best reception often occurs during night time.
WIRELESS SENSOR SIGNAL RECEIVING
1. In normal mode, press
[ SENSOR ]
key once to start receiving the sensor signal of
For example, when
CH 1
is displayed, pressing
[ SENSOR ]
key will start receive for
CH 1
only.
2.
5 minutes the icon will disappear.
Receiving wireless signal after manual reset or the
[
SENSOR ]
key is pressed
When waiting for signals, “--” will display in the readings
Good wireless sensor signal
3. If the signal for
Ch 1~8
has discontinued and
does not recover within 1 hour, the signal icon
will disappear. The temperature and humidity will
display “
Er
” for the corresponding channel.
4. If the signal does not recover within 48 hours, the
“
Er
” display will become permanent you need to
replace the batteries of “
Er
” channel’s sensors and
then press
[ SENSOR ]
key to pair up the sensors
of each “
Er
” channels again.
Note:
After replacing the batteries of the wireless sensor or the unit fails to receive wireless
[ SENSOR ]
key to manually receive that sensor signal again.
VIEW CHANNEL OF MULTIPLE WIRELESS SENSORS
1. In normal mode, press
[ CHANNEL / + ]
key to switch the display between
CH 1~8
.
2. In normal mode, press and hold
[ CHANNEL / + ]
key for 2 seconds to enter auto-
cycle mode, after a bi sounds, it will alternately displays the channels at 4 second
intervals.
3. During auto-cycle mode, press
[ CHANNEL / + ]
key once to stop auto-cycle and
display the current channel.
4. Using auto-cycle mode will only display the communicated channels. For example,
when
CH 1
and
6
have received the signal from the corresponding sensor, holding
[
CHANNEL / + ]
key for 2 seconds will only toggle the readings of
CH 1
and
6
. Other
channels will be neglected.
CH 1
CH 6
CH 1
RECEPTION OF RADIO CONTROLLED SIGNAL
The time and date are radio-controlled. The current time and date are automatically
synchronized with the signal that transmitted from RC station through wireless sensor.
Please make sure the wireless sensor is connected to the main unit.
RCC SIGNAL STRENGTH INDICATOR
The signal indicator shows signal receive status. Flashing wave segment means RCC
No RCC signal received
Received RCC signal
Note:
-
1
- Always place the unit away from interfering sources such as TV set, computer, etc.
- Avoid placing the unit on or next to metal plate.
- Closed area such as airport basement, tower block or factory is not recommended.
- Do not start reception on a moving article such as vehicle or train.
DAYLIGHT SAVING TIME (DST)
This clock has been programmed to automatically switch when the daylight saving time is
in effect. User can disable the DST function in time and calendar setting mode.
Note:
DST AUTO/OFF setting only available when RCC function is ON.
TIME AND CALENDAR SETTING
1. In normal mode, press and hold
[ TIME SET ]
key for 2 seconds to enter date and
time setting mode.
2. Press
[ CHANNEL / + ] or [ MEM / - ]
key to adjust the setting.
3. Press
[ TIME SET ]
key to enter the next setting
4.
1
hour
minute
second
year
DM/
MD
month
day
time zone
language
RCC ON/OFF
DST
AUTO / OFF
5. When you complete the setting, press
[ TIME SET ]
key or leave the unit for 60
seconds to return to normal mode.
Note:
DST AUTO/OFF setting only available when RCC function is ON.
12/24H setting
Hour/Minute/
Second setting
Year setting
Month/Day
setting
D/M
M/D
Month/day
setting
M/
D
Time zone
setting
00H
01H...23H
-23H...-01H
00H
Language
setting
EN
FR
DE
ES
IT
NL
RU
RCC setting
DST (day light
saving) setting
ALARM TIME SETTING AND DISPLAY
1. In normal time mode, press and hold
[ ALARM ]
key for 2 seconds until the alarm
2. Press
[ CHANNEL / + ] or [ MEM / - ]
key to change the value. Press and hold the
key for quick-adjust.
3.
4. When you complete the setting of Minute, Press
[ ALARM ]
key or leave the unit for
60 seconds to return to normal mode.