3. DESCRIPTION OF ELECTRONIC COMPONENTS
AND THEIR OPERATION
Power Terminals:
1 - Control board power supply (K10)
2 - Heating element output (L) (FASTON 3)
3 - Compressor output (L) (FASTON 3)
4 - Relay input (L) (FASTON 1)
5 - 4-way valve and coil valve output (L) (K3)
Control, regulation:
6 - Temperature sensor input T4 / T5 (K5)
7 - Temperature sensors input T1 / T3 (K1)
8 - Terminal temperature sensors T4 / T5 COM,
fan control (K6)
9 - Anode input Mg
10 - Grounding
Temperature sensors
T1 = Water temperature and quantity of hot water
in the tank
T2 = Water temperature and quantity of hot water
in the tank (central sensor on the strip)
T3 = Water temperature and quantity of hot water
in the tank
T4 = temperature of the incoming air
T5 = evaporator temperature
Temperature sensors T1-T2-T3 (NTC 20K)
on the strip
T4-T5 temperature sensor (NTC 10K)