TB-6584
Page 13 of 13
© 2016 DESCO INDUSTRIES, INC.
Employee Owned
Specifications
SMARTLOG V5™
Operating Voltage:
100-240 VAC, 50/60 Hz
Operating Temperature:
70°F to 85°F (21°C to 30°C) for 1 gigohm test limit
41°F to 85°F (5°C to 30°C) for all other test limits
Environmental Requirements:
Indoor use only at altitudes less than 6500 ft. (2 km)
Maximum relative humidity of 80% up to 85°F (30°C)
decreasing linearly to 50% @ 85°F (30°C)
Maximum relative humidity of 50% at 1 Gigohm setting
Dimensions:
7.9" x 5.8" x 1.9"
(20.1 cm x 14.7 cm x 4.8 cm)
Weight:
2.0 lbs (0.9 kg)
Test Accuracy:
±20% for 1 gigohm footwear test limit
±10% for all other test limits
Test Switch Voltage:
5 VDC @ open circuit
Wrist Strap and Footwear Test Voltage:
30 VDC @ open circuit
Test current is limited by resistors and varies on the test
range setting (100 kilohms - 1 gigohm)
Memory Capacity
2
:
Test ID Length Test Transactions
4
16,100
5
15,300
6
14,600
7
14,000
8
13,400
9
12,900
10
12,400
11
11,900
12
11,500
13
11,100
14
10,700
15
10,400
16
10,100
2
This only applies should the SmartLog V5 lose
communication with the TEAM5 Software. Test
transactions are automatically polled from the
SmartLog’s memory when connected to TEAM5.
Limited Warranty, Warranty Exclusions, Limit of
Liability and RMA Request Instructions
See the EMIT Warranty -
http://emit.descoindustries.com/Warranty.aspx
DUAL INDEPENDENT FOOT PLATE
Dimensions
14.0" x 16.0" x 0.9"
(35.6 cm x 40.1 cm x 2.3 cm)
Weight
7.5 lbs (3.4 kg)
www.
.com