Side Discharge Condensers

19

operation anD maintenanCe

The S1C/H and S2C outdoor sections 

are  the  compressor  bearing  units  of  the 

system.  It  operates  at  the  command  of 

the    indoor  section  or  room  thermostat. 

Therefore,  the  system  operation  will  be 

described in the manual pertaining to the 

indoor section.

EMI  units  are  designed  and  con

-

structed  for  reliability  and  long  life  with 

minimal  maintenance.  You  can  assure 

peak  operating  efficiency  by  regularly 

inspecting  for  free  air  passage  into  and 

through the coil. If debris collects on the air 

coil, it should be cleaned by "back-flushing" 

with a spray of water or vacuuming.

 TURN 

OFF  POWER  SUPPLY  FIRST.

  Outdoor 

units may be cleaned or waxed if desired.  

Use  a  non-abrasive  car  wax  (on  metal 

surfaces only).

This  unit  is  equipped  with  a  perma

-

nently lubricated motor. Although oiling is 

not necessary, adding a few drops through 

the oiling ports twice yearly will extend the 

life of the motor. 

Do not over oil.

Panels should remain on the unit at all 

times. Service should be performed by a 

QUALIFIED

 service agency only.

SpeCiFiC CHangeS

All  EMI  products  are  subject  to  on

-

going  development  programs  so  design 

and  specifications  may  change  without 

notice. Please consult the factory for more 

information.

Starting tHe Unit

• In low ambient cooling 9-12 Btuh units, 

if  a  crankcase  heater  is  installed, 

power  the  system  24  hours  before 

attempting  to  start  the  unit  in  cool 

weather (below 60° F). 

• After doing a final system check using 

the Operation Charts (supplied on pre

-

vious pages). Record results on Test 

Unit Data Sheet on page 26.

preperation For Start-Up

• Remove gauge set. Mount all access 

panels and make sure they are prop

-

erly secured. 

• Make final visual inspection and repair 

any deficiencies.

note:

  

A hard start kit may be required 

for units in low voltage applications.

Single-Zone anD DUal-Zone ConDenSer SeqUenCe oF operation      

  EMI  America  Series  condensers  are 

designed  to  operate  with  EMI  America 

Series  evaporators.  Both  the  condenser 

(outdoor  unit)  and  evaporator  (indoor 

unit) have a high volt service connection. 

Each is to be independently connected to 

the electrical service panel. (See the unit 

name  plate  for  the  correct  breaker  type 

and  size).  The  outdoor  and  indoor  units 

are also connected to each other through 

a low volt interconnect wiring. A 24

v trans-

former located in the indoor unit provides 

the low v

olt power source. 

Straight  cool  condensers  are  designed 

to operate as a single stage cooling unit. 

Heat  pump  condensers  are  designed  to 

operate  as  a  single  stage  cooling  two 

stage  heating  unit.  For  proper  operation 

the unit must be matched with an appro

-

priate EMI indoor unit with unit mounted 

controls and/or wall mounted thermostat. 

For  two-stage  heating  operation  the  in

-

door unit must be equipped with an elec

-

tric strip heater.

Содержание AmericaSeries S1C2

Страница 1: ...ump S1C S1H Nominal Circuit Capacities S1C S1H 9 000 12 000 18 000 24 000 Btuh and S1C 30 36 Btuh Cooling Only S2C Nominal Circuit Capacities 9 000 12 000 Btuh Enviromaster International LLC 5780 Succ...

Страница 2: ...he same as the electric supply to the unit The EMI AmericaSeries condens ing unit must be connected only to a properly grounded electrical sup ply Do not fail to properly ground this unit Turn off the...

Страница 3: ...9 12 only Low voltage terminal connections Large capacity suction accumulator 09 12 only Solid core filter drier 09 12 only Thermostatically controlled crankcase heater 09 12 S1H s H P S High pressure...

Страница 4: ...1 Place the unit on a flat concrete surface or pad if on the ground Roof mounting should use a build up platform to avoid intake of hot air from the roof 2 In areas of heavy snowfall condens ers shou...

Страница 5: ...sor Accumulator Capacitor Filter Drier 3 Use only HACR type breakers or time delay fuses Select the wire size accord ing to the ampacity rating 4 To access electrical connections and wiring diagram a...

Страница 6: ...he unit and into the electrical box and an chor with the strain relief fitting 7 Run wires to the high volt pigtail in the con trolboxandattachL1andL2connections Also run green wire to ground wire Hig...

Страница 7: ...Use only clean refrigeration tubing Use tube benders to guard against kinking Avoid piping on wet and rainy days and insulate suction line Be certain that plastic end caps remain in place when inserti...

Страница 8: ...r is 30 feet tall then a P trap is recommended at the 15 foot mark of the suction riser see Figure 1 AP trap may be fabricated using 2 street elbows and 2 regular elbow A prefab Installation Instructi...

Страница 9: ...tubing and insert into fittings 5 Attach manifold set 6 Evacuate line to 500 microns or less to ensure all moisture has been removed and there are no leaks Refrigerant Refer to Refrigerant Charge Tab...

Страница 10: ...tables starting on page 10 S1C REFRIGERANT CHARGE TABLE CONDENSER EVAPORATOR PAIRING LINE CHG FT FACTORY CHARGE S1C9 CAH12 25 oz 37 oz S1C2 CAH12 25 oz 40 oz S1C8 CAH24 56 oz 51 oz S1C4 CAH24 56 oz 65...

Страница 11: ...sures temperatures on system supplied with Low Ambient Option the fan cycle switchshouldbejumpedoutofthecircuit temporarily to obtain accurate data Installation Instructions REFRIGERANT PROCESSING co...

Страница 12: ...www enviromaster com Side Discharge Condensers 12 SINGLE ZONE OPERATION CHARTS...

Страница 13: ...www enviromaster com Side Discharge Condensers 13 SINGLE ZONE OPERATION CHARTS...

Страница 14: ...www enviromaster com Side Discharge Condensers 14 SINGLE ZONE OPERATION CHARTS...

Страница 15: ...www enviromaster com Side Discharge Condensers 15 SINGLE ZONE OPERATION CHARTS...

Страница 16: ...www enviromaster com Side Discharge Condensers 16 SINGLE ZONE Heat Pump OPERATION CHARTS...

Страница 17: ...www enviromaster com Side Discharge Condensers 17 SINGLE ZONE Heat Pump OPERATION CHARTS...

Страница 18: ...www enviromaster com Side Discharge Condensers 18 Dual ZONE OPERATION CHARTS...

Страница 19: ...ing 9 12 Btuh units if a crankcase heater is installed power the system 24 hours before attempting to start the unit in cool weather below 60 F After doing a final system check using the Operation Cha...

Страница 20: ...placed in heating mode with the set point temperature above room tempera ture the compressor and outdoor fan R Y will energize When the indoor control is satisfied and the room temper ature rises abo...

Страница 21: ...fan will switch off the re versing valve will energize and the defrost board will energize the indoor electric heat relay through the W terminal After the two second defrost cycle is complete the unit...

Страница 22: ...al Dimensions Model Size S2C A B C 99 32 15 36 22 92 32 15 40 Shipping Weight Model Size Lbs 99 129 22 167 92 157 S2C ELECTRICAL SPECIFICATIONS capacity Volts HZ Phase Fan Mtr Compressor Total AMPS MC...

Страница 23: ...f S1C9 CAH12 9 000 13 0 79 11 7 R22 S1C2 CAH12 12 000 13 0 72 12 2 R22 S1C8 CAH24 18 000 13 0 76 12 3 R22 S1C4 CAH24 23 000 13 0 67 11 8 R22 S1C3 CAC36 30 000 14 0 82 12 0 R22 S1C6 CAC36 36 000 13 0 7...

Страница 24: ...73 12 1 3 8 R22 S1H4 WLH24 23 000 20 600 13 0 8 3 71 11 9 3 5 R22 NOTE All EMI products are subject to ongoing development Design and specifications may change without notice S1C S1H Specifications a...

Страница 25: ...R22 Cooling Systems with S2C Side discharge Wall Unit s Condenser Btuh SEER SHR EER Ref WLH09 WLH09 S2C99 18 000 13 0 80 11 9 R22 WLH12 WLH12 S2C22 23 000 13 0 72 12 4 R22 WLH09 WLH12 S2C92 21 000 13...

Страница 26: ...Unit Performance Data Date Model Number Technician Serial Number Mode Cooling Indoor Section Notes Evaporator Entering Air DB Evaporator Entering Air WB Evaporator Leaving Air DB Evaporator Leaving Ai...

Страница 27: ...Line Indoor Units outdoor Units S1C S1H Single Zone Side Discharge S2C S2H Dual Zone Side Discharge WLC WLH High Wall Air handler CAc CAH Cassette Air handler UNC UNH Universal Floor or Ceiling Air H...

Страница 28: ...Phone 1 800 228 9364 Fax 1 800 232 9364 5780 Success Drive Rome NY 13440...

Отзывы: