background image

S1C/S1H Single-Zone & S2C Dual-Zone 

SiDe DiSCHarge DuCtleSS Split SyStem 

ConDenSing unitS

 

 

P/N# 240005897 Rev. B  [05/08]

Straight Cool/heat pump S1C/S1h 

Nominal Circuit Capacities S1C/S1H: 
9,000, 12,000, 18,000, 24,000 Btuh and 
S1C 30-36 Btuh

Cooling only S2C

Nominal Circuit Capacities: 

9,000-12,000 Btuh

Enviromaster International LLC
5780 Success Dr.
Rome, NY 13440
www.enviromaster.com

in

St

alla

tion, opera

tion an

D

 mainten

an

Ce 

manu

al

An ISO 9001-2000 Certified Company

S1C/S1h

S2C

Содержание AmericaSeries S1C2

Страница 1: ...ump S1C S1H Nominal Circuit Capacities S1C S1H 9 000 12 000 18 000 24 000 Btuh and S1C 30 36 Btuh Cooling Only S2C Nominal Circuit Capacities 9 000 12 000 Btuh Enviromaster International LLC 5780 Succ...

Страница 2: ...he same as the electric supply to the unit The EMI AmericaSeries condens ing unit must be connected only to a properly grounded electrical sup ply Do not fail to properly ground this unit Turn off the...

Страница 3: ...9 12 only Low voltage terminal connections Large capacity suction accumulator 09 12 only Solid core filter drier 09 12 only Thermostatically controlled crankcase heater 09 12 S1H s H P S High pressure...

Страница 4: ...1 Place the unit on a flat concrete surface or pad if on the ground Roof mounting should use a build up platform to avoid intake of hot air from the roof 2 In areas of heavy snowfall condens ers shou...

Страница 5: ...sor Accumulator Capacitor Filter Drier 3 Use only HACR type breakers or time delay fuses Select the wire size accord ing to the ampacity rating 4 To access electrical connections and wiring diagram a...

Страница 6: ...he unit and into the electrical box and an chor with the strain relief fitting 7 Run wires to the high volt pigtail in the con trolboxandattachL1andL2connections Also run green wire to ground wire Hig...

Страница 7: ...Use only clean refrigeration tubing Use tube benders to guard against kinking Avoid piping on wet and rainy days and insulate suction line Be certain that plastic end caps remain in place when inserti...

Страница 8: ...r is 30 feet tall then a P trap is recommended at the 15 foot mark of the suction riser see Figure 1 AP trap may be fabricated using 2 street elbows and 2 regular elbow A prefab Installation Instructi...

Страница 9: ...tubing and insert into fittings 5 Attach manifold set 6 Evacuate line to 500 microns or less to ensure all moisture has been removed and there are no leaks Refrigerant Refer to Refrigerant Charge Tab...

Страница 10: ...tables starting on page 10 S1C REFRIGERANT CHARGE TABLE CONDENSER EVAPORATOR PAIRING LINE CHG FT FACTORY CHARGE S1C9 CAH12 25 oz 37 oz S1C2 CAH12 25 oz 40 oz S1C8 CAH24 56 oz 51 oz S1C4 CAH24 56 oz 65...

Страница 11: ...sures temperatures on system supplied with Low Ambient Option the fan cycle switchshouldbejumpedoutofthecircuit temporarily to obtain accurate data Installation Instructions REFRIGERANT PROCESSING co...

Страница 12: ...www enviromaster com Side Discharge Condensers 12 SINGLE ZONE OPERATION CHARTS...

Страница 13: ...www enviromaster com Side Discharge Condensers 13 SINGLE ZONE OPERATION CHARTS...

Страница 14: ...www enviromaster com Side Discharge Condensers 14 SINGLE ZONE OPERATION CHARTS...

Страница 15: ...www enviromaster com Side Discharge Condensers 15 SINGLE ZONE OPERATION CHARTS...

Страница 16: ...www enviromaster com Side Discharge Condensers 16 SINGLE ZONE Heat Pump OPERATION CHARTS...

Страница 17: ...www enviromaster com Side Discharge Condensers 17 SINGLE ZONE Heat Pump OPERATION CHARTS...

Страница 18: ...www enviromaster com Side Discharge Condensers 18 Dual ZONE OPERATION CHARTS...

Страница 19: ...ing 9 12 Btuh units if a crankcase heater is installed power the system 24 hours before attempting to start the unit in cool weather below 60 F After doing a final system check using the Operation Cha...

Страница 20: ...placed in heating mode with the set point temperature above room tempera ture the compressor and outdoor fan R Y will energize When the indoor control is satisfied and the room temper ature rises abo...

Страница 21: ...fan will switch off the re versing valve will energize and the defrost board will energize the indoor electric heat relay through the W terminal After the two second defrost cycle is complete the unit...

Страница 22: ...al Dimensions Model Size S2C A B C 99 32 15 36 22 92 32 15 40 Shipping Weight Model Size Lbs 99 129 22 167 92 157 S2C ELECTRICAL SPECIFICATIONS capacity Volts HZ Phase Fan Mtr Compressor Total AMPS MC...

Страница 23: ...f S1C9 CAH12 9 000 13 0 79 11 7 R22 S1C2 CAH12 12 000 13 0 72 12 2 R22 S1C8 CAH24 18 000 13 0 76 12 3 R22 S1C4 CAH24 23 000 13 0 67 11 8 R22 S1C3 CAC36 30 000 14 0 82 12 0 R22 S1C6 CAC36 36 000 13 0 7...

Страница 24: ...73 12 1 3 8 R22 S1H4 WLH24 23 000 20 600 13 0 8 3 71 11 9 3 5 R22 NOTE All EMI products are subject to ongoing development Design and specifications may change without notice S1C S1H Specifications a...

Страница 25: ...R22 Cooling Systems with S2C Side discharge Wall Unit s Condenser Btuh SEER SHR EER Ref WLH09 WLH09 S2C99 18 000 13 0 80 11 9 R22 WLH12 WLH12 S2C22 23 000 13 0 72 12 4 R22 WLH09 WLH12 S2C92 21 000 13...

Страница 26: ...Unit Performance Data Date Model Number Technician Serial Number Mode Cooling Indoor Section Notes Evaporator Entering Air DB Evaporator Entering Air WB Evaporator Leaving Air DB Evaporator Leaving Ai...

Страница 27: ...Line Indoor Units outdoor Units S1C S1H Single Zone Side Discharge S2C S2H Dual Zone Side Discharge WLC WLH High Wall Air handler CAc CAH Cassette Air handler UNC UNH Universal Floor or Ceiling Air H...

Страница 28: ...Phone 1 800 228 9364 Fax 1 800 232 9364 5780 Success Drive Rome NY 13440...

Отзывы: