5.0 specifications
Description
Catalog Number
Passive Card (SDUCFRELAYCARD)
Active Cards
(SDUENETIPCARD, SDUMBUSCARD,
SDUPNETCARD, SDUECATCARD)
Input
Nominal Voltage
+3.3 V ±5 %
Standby signal
Active low via normally open momentary switch
Frequency
50/60 Hz
Output
LED Diagnostics
Refer to diagram
Refer to diagram
ns = network status, Ms=Module status
Relay Logic Signals
Refer to diagram
—
Relay Contact Ratings
60V peak, 1A
—
Case/Enclosure Material
Housing: LCP(Liquid Crystal Polymer)
Color: natural, thermoplastic,UL 94 V-0
Weight & Dimensions
H x W x D, in. (mm)
0.91 x 2.0 x 2.2 (23 x 50 x 55) approximate
Net Weight, oz. (g)
1.0 (28.4) approximate
EMC
Immunity/Emissions
emission en 61000-6-4 en55016-2-3 Radiated emission en55022 Conducted emission
Immunity en 61000-6-2 en61000-4-2 electrostatic discharge, en61000-4-3 Radiated immunity.
en61000-4-4 Fast transients/burst, en61000-4-6 Conducted immunity
Approvals
en/IeC 60950-1 ; UL/CsA 60950-1 Pollution Degree 3 ; UL 508 Pollution Degree 3 CsA 107.1;
eU RoHs2,China RoHs2
Temperature °F (°C)
storage: -40 to +185 (-40 to +85)
operating: -40 to +158 (-40 to +70) Convection cooling; no forced air required.
Vibration
operating: IeC60068-2-6, sine Wave: 10Hz to 500Hz @19.6m/s², displacement of 0.35mm,
60 min per axis for all X, Y, Z direction.
non-operating: IeC60068-2-6, Random : 5hz to 500Hz (2.09Grms); 20 min per axis for all X,Y,Z direction.
Shock
operating: IeC60068-2-27, Half sine Wave: 10G for a duration of 11ms, shock for 1 direction (X axis).
non-operating: IeC60068-2-27, Half sine Wave : 50G for duration of 11ms, 3 shocks for each 3 directions.
Humidity
1% to 90% RH, noncondensing; IeC 68-2-2, 68-2-3
Warranty
2 Years
MTBF (bellcore)
1,968,800 Hours
General Protection/
Safety
Protected against Continuous short -circuit, Continuous overload, Continuous open circuit. Galvanic Isolation:
I/P to o/P: 3KVac, I/P to GnD: 1.5KVac, o/P to GnD: 0.5KVac
Protection class 1 (IeC536), degree of protection IP20 (IeC 529) safe low voltage: seLV (acc. en60950); RoHs
Approvals apply for ActiveCards. Contact technical support for Passive Cards.
sDU AC - A seRIes CoMM CARDs InstRUCtIon MAnUAL |
15