SI-DeviceNet User Guide
Issue Number: 2
11.4
Control Supervisor
Class:
0x29 (41)
11.4.1 RunFwd
Set to 1 to run the drive in the forward direction.
Get/Set Pr
06.042
bit 1
11.4.2 RunRev
Set to 1 to run the drive in the reverse direction.
Get/Set Pr
06.042
bit 3
11.4.3 NetCtrl
Switches the drive between terminal and fieldbus control.
Get/Set Pr
06.042
bit 7
Set False terminal control
Set True fieldbus control
11.4.4 State
This returns a code to indicate the current operating state of the drive.
Name:
RunFwd
Class
0x29
Default
Instance
0x01
Data Type
USINT
Attribute
0x03
Access
Get/Set
Name:
RunRev
Class
0x29
Default
Instance
0x01
Data Type
USINT
Attribute
0x04
Access
Get/Set
Name:
NetCtrl
Class
0x29
Default
Instance
0x01
Data Type
USINT
Attribute
0x05
Access
Get/Set
Name:
State
Class
0x29
Default
N/A
Instance
0x01
Data Type
USINT
Attribute
0x05
Access
Get