Bus Off errors will generally only occur if the DeviceNet network is broken, the wiring
becomes faulty or there is noise on the network. However, in some applications, such as
a continuous casting process, there is a requirement for the drive to continue to run in
the event of a major network failure.
When Pr
S.01.034
is set to Disable (1), the BUS Off condition may still be entered, but
the SI-DeviceNet does not trip the drive. Some external provision must be made to
disable the drive when the process has reached a point at which it is safe to stop.
There are 2 instances of the Motor Data object. Instance 1 will represent the Menu 5
motor information (Motor Map 1) and instance 2 will represent the menu 21 motor map.
(Motor Map 2) The instance being used by the other dependant DeviceNet objects will
be determined by Pr
21.015
. Pr
21.015
is polled in the background task, so the user
should be aware that during motor map changeover, the rpm speed reference might not
be accurate.
Motor 1 type
S.01.040
Default
FC DC Motor (2)
Range
FC DC Motor (2) to Trapezoidal PM BL
Motor (10)
Access
RO
Motor 2 type
S.01.041
Default
FC DC Motor (2)
Range
FC DC Motor (2) to Trapezoidal PM BL
Motor (10)
Access
RO