User Instructions
Part Number IOM – 87376-7 July 2016, Rev 1.
67
Figure 69
Logic Board of Controller
Parts Overview:
1.
Fuse F10a for the Binary Outputs
2.
Fuse F10b for Auxillary
Table 24.
Fuses on the Logic Board
Fuse
Value
Manufacturer
F10a
1AT
Littelfuse 454 NANO
2
Slo-Blo
®
träge
F10b
4AT
Littelfuse 454 NANO
2
Slo-Blo
®
träge
The frequency inverter is protected by an input fuse and the explosionproof version also has a
thermal fuse (see
Section 13.7.3
).
Section 23:
Lubricant Recommendation and
Requirements
23.1
Main Body
Operating oil: DIN 51 517 - CLP - HC
Fully synthetic high-performance gear oils based on poly-alpha-olefins (PAO)
Temperature: -25
o
C to +60
o
C
Viscosity class: 320 ISO VG
Lubricant requirement: 0.25 Lt
23.2
Output Type A and Spindle Drive (Linear
Acutators):
Содержание RTS FQ