7.5.1
Specific conditions of use
The dimensions of the flameproof joints are other than the relevant minimum or
maximum values required by Table 3 of IEC/EN 60079-1:2014 for IIB + H
2
, as detailed
below.
Table 7-1: Minimum and maximum widths
Flamepath description Type of joint
Minimum width
L
Maximum gap
ic
Joint formed by window
against the enclosure
Flanged
0.4232 in (10.75 mm)
0.0008 in (0.02 mm)
Enclosure end-cap
spigot
Cylindrical
0.59 in (15 mm)
0.0031 in (0.08 mm)
Gaps must not be machined to be any larger than the values of
ic
, and width must not be
modified to be any smaller than the values of
L
shown in the table above.
The equipment must only be charged in a safe area with the batteries removed from the
flameproof enclosure. The charge conditions are as follows:
Maximum charge voltage: 16.8 V
Maximum charge current: 4 A
The charge voltage must not exceed these values.
Reference Manual
Product certifications
00809-0800-4975
May 2022
Rosemount FS-UVIR-975
25
Содержание Rosemount FS-UVIR-975
Страница 1: ...Reference Manual 00809 0800 4975 Rev DD May 2022 Rosemount FS UVIR 975 ...
Страница 4: ...4 ...
Страница 6: ...Contents Reference Manual May 2022 00809 0800 4975 6 Emerson com Rosemount ...
Страница 14: ...Operation Reference Manual May 2022 00809 0800 4975 14 Emerson com Rosemount ...
Страница 18: ...Maintenance Reference Manual May 2022 00809 0800 4975 18 Emerson com Rosemount ...
Страница 20: ...Ordering information Reference Manual May 2022 00809 0800 4975 20 Emerson com Rosemount ...
Страница 26: ...Product certifications Reference Manual May 2022 00809 0800 4975 26 Emerson com Rosemount ...