139
Reference Manual
00809-0100-4107, Rev BA
Appendix A: Specifications and Reference Data
April 2013
Appendix A: Specifications and Reference Data
Isolation Valve for Flo-Tap Models
Standard
Standard
0
Not Applicable or Customer Supplied
★
Temperature Measurement
Standard
Standard
T
Integral RTD – not available with Flanged model greater than class 600#
★
0
No Temperature Sensor
★
Expanded
R
Remote Thermowell and RTD
Transmitter Connection Platform
Standard
Standard
3
Direct-mount, Integral 3-valve Manifold– not available with Flanged model greater than class 600
★
5
Direct -mount, 5-valve Manifold – not available with Flanged model greater than class 600
★
7
Remote-mount NPT Connections (
1
/
2
-in. FNPT)
★
Expanded
8
Remote-mount SW Connections (
1
/
2
-in.)
Differential Pressure Range
Standard
Standard
1
0 to 25 in H
2
O (0 to 62,3 mbar)
★
2
0 to 250 in H
2
O (0 to 623 mbar)
★
3
0 to 1000 in H
2
O (0 to 2,5 bar)
★
Transmitter Output
Standard
Standard
A
(2)
4–20 mA with digital signal based on HART Protocol
★
F
F
OUNDATION
fieldbus Protocol
★
W
PROFIBUS PA Protocol
★
Expanded
M
Low-Power, 1-5 Vdc with Digital Signal Based on HART Protocol
Transmitter Housing Material
Conduit Entry Size
Standard
Standard
A
Aluminum
1
/
2
-14 NPT
★
B
Aluminum
M20 x 1.5
★
J
SST
1
/
2
-14 NPT
★
K
(3)
SST
M20 x 1.5
★
Expanded
D
Aluminum
G
1
/
2
SST
G
1
/
2
Transmitter Performance Class
Standard
Standard
1
2.0% flow rate accuracy, 5:1 flow turndown, 2-year stability
★
Options
(Include with selected model number)
Pressure Testing
Expanded
P1
(4)
Hydrostatic Testing with Certificate
Extended Hydrostatic Testing
Special Cleaning
Expanded
P2
Cleaning for Special Services
PA
Cleaning per ASTM G93 Level D (Section 11.4)
Table 14. Rosemount 2051CFA Annubar Flowmeter Ordering Information
★
The Standard offering represents the most common options. The starred options (
★
) should be selected for best delivery.
__
The Expanded offering is subject to additional delivery lead time.
Содержание Rosemount 2051
Страница 2: ......
Страница 4: ......
Страница 102: ...92 Reference Manual 00809 0100 4107 Rev BA Section 6 Troubleshooting April 2013 Troubleshooting ...
Страница 213: ...203 Reference Manual 00809 0100 4107 Rev BA Appendix B Product Certifications April 2013 Product Certifications ...
Страница 214: ...204 Reference Manual 00809 0100 4107 Rev BA Appendix B Product Certifications April 2013 Product Certifications ...
Страница 227: ......