98
Quantum MP User Guide
www.emersonct.com Issue: A4
Parameter
Range(
)
Default(
)
Type
1.01
Speed reference selected
{di01, 0.36}
±MAX_SPEED_REF rpm
RO
Bi
NC PT
1.02
Pre-skip filter reference
±MAX_SPEED_REF rpm
RO
Bi
NC PT
1.03
Pre-ramp reference
{di02, 0.37}
±MAX_SPEED_REF rpm
RO
Bi
NC PT
1.04
Reference offset
±10,000.0 rpm
0.0
RW
Bi
US
1.05
Jog reference
0 to 1,000.0 rpm
0.0
RW Uni
US
1.06
Maximum reference clamp
{SE02, 0.23}
SPEED_LIMIT_MAX rpm
1,000.0
RW Uni
US
1.07
Minimum reference clamp
{SE01, 0.22}
±SPEED_LIMIT_MAX rpm
0.0
RW
Bi
PT US
1.08
Negative minimum reference
clamp enable
OFF (0) or On (1)
OFF (0)
RW
Bit
US
1.09
Reference offset select
OFF (0) or On (1)
OFF (0)
RW
Bit
US
1.10
Bipolar reference enable
OFF (0) or On (1)
OFF (0)
RW
Bit
US
1.11
Reference enabled indicator
{di11, 0.46}
OFF (0) or On (1)
RO
Bit
NC PT
1.12
Reverse selected indicator
{di12, 0.47}
OFF (0) or On (1)
RO
Bit
NC PT
1.13
Jog selected indicator
{di13, 0.48}
OFF (0) or On (1)
RO
Bit
NC PT
1.14
Reference selector
{SE05, 0.26}
0 to 6
0 (A1.A2)
RW Txt
US
1.15
Preset selector
0 to 9
0
RW Uni
US
1.16
Preset reference selector
timer
0 to 400.0s
10.0
RW Uni
US
1.17
Keypad control reference
±MAX_SPEED_REF rpm
0.0
RO
Bi
NC PT PS
1.18
Precision reference coarse
±MAX_SPEED_REF rpm
0.0
RW
Bi
US
1.19
Precision reference fine
0.0 to 0.099 rpm
0.000
RW Uni
US
1.20
Precision reference update
disable
OFF (0) or On (1)
OFF (0)
RW
Bit
NC
1.21
Preset reference 1
±MAX_SPEED_REF rpm
0.0
RW
Bi
US
1.22
Preset reference 2
±MAX_SPEED_REF rpm
0.0
RW
Bi
US
1.23
Preset reference 3
±MAX_SPEED_REF rpm
0.0
RW
Bi
US
1.24
Preset reference 4
±MAX_SPEED_REF rpm
0.0
RW
Bi
US
1.25
Preset reference 5
±MAX_SPEED_REF rpm
0.0
RW
Bi
US
1.26
Preset reference 6
±MAX_SPEED_REF rpm
0.0
RW
Bi
US
1.27
Preset reference 7
±MAX_SPEED_REF rpm
0.0
RW
Bi
US
1.28
Preset reference 8
±MAX_SPEED_REF rpm
0.0
RW
Bi
US
1.29
Skip reference 1
0 to 10,000 rpm
0
RW Uni
US
1.30
Skip reference band 1
0 to 250 rpm
5
RW Uni
US
1.31
Skip reference 2
0 to 10,000 rpm
0
RW Uni
US
1.32
Skip reference band 2
0 to 250 rpm
5
RW Uni
US
1.33
Skip reference 3
0 to 10,000 rpm
0
RW Uni
US
1.34
Skip reference band 3
0 to 250 rpm
5
RW Uni
US
1.35
Reference in rejection zone
OFF (0) or On (1)
RO
Bit
NC PT
1.36
Analog reference 1
±MAX_SPEED_REF rpm
0
RO
Bi
NC
1.37
Analog reference 2
±MAX_SPEED_REF rpm
0
RO
Bi
NC
1.38
Percentage trim
±100.00%
0.00
RW
Bi
NC
1.39
Velocity feed forward
±10,000.0 rpm
RO
Bi
NC PT
1.40
Velocity feed forward select
OFF (0) or On (1)
RO
Bit
NC PT
1.41
Reference select flag 1
OFF (0) or On (1)
OFF (0)
RW
Bit
NC
1.42
Reference select flag 2
OFF (0) or On (1)
OFF (0)
RW
Bit
NC
1.43
Reference select flag 3
OFF (0) or On (1)
OFF (0)
RW
Bit
NC
1.44
Reference select flag 4
OFF (0) or On (1)
OFF (0)
RW
Bit
NC
1.45
Reference select flag 5
OFF (0) or On (1)
OFF (0)
RW
Bit
NC
1.46
Reference select flag 6
OFF (0) or On (1)
OFF (0)
RW
Bit
NC
1.47
Reference select flag 7
OFF (0) or On (1)
OFF (0)
RW
Bit
NC
1.48
Reference timer reset flag
OFF (0) or On (1)
OFF (0)
RW
Bit
NC
1.49
Reference selected indicator
1 to 6
RO Uni
NC
1.50
Preset reference selected
indicator
1 to 8
RO Uni
NC PT
1.51
Power-up keyboard control
mode reference
0 to 2
0
RW Txt
US
1.52
Reference select flags
OFF (0) or On (1)
OFF (0)
RW
Bit
NC
RW
Read / Write
RO
Read only
Uni
Unipolar
Bi
Bi-polar
Bit
Bit parameter
Txt
Text string
FI
Filtered
DE
Destination
NC
Not copied
RA
Rating dependent
PT
Protected
US
User save
PS