128
Quantum MP User Guide
www.emersonct.com Issue: A4
Parameter
Range(
)
Default(
)
Type
12.01
Threshold detector 1 output
OFF (0) or On (1)
RO
Bit
NC PT
12.02
Threshold detector 2 output
OFF (0) or On (1)
RO
Bit
NC PT
12.03
Threshold detector 1 source
Pr
0.00
to
22.99
Pr
0.00
RW Uni
PT US
12.04
Threshold detector 1 level
0 to 100.00%
0.00
RW Uni
US
12.05
Threshold detector 1 hysteresis
0 to 25.00%
0.00
RW Uni
US
12.06
Threshold detector 1 output invert
OFF (0) or On (1)
OFF (0)
RW
Bit
US
12.07
Threshold detector 1 destination
Pr
0.00
to
22.99
Pr
0.00
RW Uni
PT US
12.08
Variable selector 1 source 1
Pr
0.00
to
22.99
Pr
0.00
RW Uni
PT US
12.09
Variable selector 1 source 2
Pr
0.00
to
22.99
Pr
0.00
RW Uni
PT US
12.10
Variable selector 1 mode
0 to 10
0
RW Uni
US
12.11
Variable selector 1 destination
Pr
0.00
to
22.99
Pr
0.00
RW Uni
PT US
12.12
Variable selector 1 output
±100.00%
RO Uni
NC PT
12.13
Variable selector 1 source 1 scaling
±4.000
1.000
RW Uni
US
12.14
Variable selector 1 source 2 scaling
±4.000
1.000
RW Uni
US
12.15
Variable selector 1 control
0 to 100.00
0.00
RW Uni
US
12.23
Threshold detector 2 source
Pr
0.00
to
22.99
Pr
0.00
RW Uni
PT US
12.24
Threshold detector 2 level
0 to 100.00%
0.00
RW Uni
US
12.25
Threshold detector 2 hysteresis
0 to 25.00%
0.00
RW Uni
US
12.26
Threshold detector 2 output invert
OFF (0) or On (1)
OFF (0)
RW
Bit
US
12.27
Threshold detector 2 destination
Pr
0.00
to
22.99
Pr
0.00
RW Uni
PT US
12.28
Variable selector 2 source 1
Pr
0.00
to
22.99
Pr
0.00
RW Uni
PT US
12.29
Variable selector 2 source 2
Pr
0.00
to
22.99
Pr
0.00
RW Uni
PT US
12.30
Variable selector 2 mode
0 to 10
0
RW Uni
US
12.31
Variable selector 2 destination
Pr
0.00
to
22.99
Pr
0.00
RW Uni
PT US
12.32
Variable selector 2 output
±100.00%
RO Uni
NC PT
12.33
Variable selector 2 source 1 scaling
±4.000
1.000
RW Uni
US
12.34
Variable selector 2 source 2 scaling
±4.000
1.000
RW Uni
US
12.35
Variable selector 2 control
0 to 100.00
0.00
RW Uni
US
12.40
Brake release
OFF (0) or On (1)
RO Uni
NC PT
12.41
Brake controller enable
0 to 3
0
RW Txt
US
12.43
Lower current threshold
0 to 150%
10%
RW Uni
US
12.45
Brake apply speed
0 to 200rpm
5rpm
RW Uni
US
12.46
Brake apply speed delay
0 to 25.0s
1.0s
RW Uni
US
12.47
Post-brake release delay
0 to 25.0s
1.0s
RW Uni
US
12.48
Brake apply delay
0 to 25.0s
1.0s
RW Uni
US
12.49
Enable position controller during brake
release
OFF (0) or On (1)
OFF (0)
RW
Bit
US
12.50
Field active
OFF (0) or On (1)
OFF (0)
RW
Bit
US
12.51
External field control
OFF (0) or On (1)
OFF (0)
RW
Bit
US
RW
Read / Write
RO
Read only
Uni
Unipolar
Bi
Bi-polar
Bit
Bit parameter
Txt
Text string
FI
Filtered
DE
Destination
NC
Not copied
RA
Rating dependent
PT
Protected
US
User save
PS