23
emersonfans.com
Please contact 1-800-654-3545 for further assistance
ETL Model No.: CF965
9. Wall Control Installation
(Continued)
3-WAY WIRING DIAGRAM:
NEW CONSTRUCTION
NOTE: Retrofit 3-way installations are likely to include
two traveler wires between the two wall boxes. In new
construction, only one traveler wire Is required (See
Figure 35).
9.14
Screw the SW605 wall control into wall box using the
supplied screws. Leave the SW605 wall control in “OFF”
mode until fan installation is completed.
9.15
The SW605 wall control is supplied with a white, ivory, and
almond color switch covers. Choose the finish that best
suits your needs and snap the cover onto the SW605 wall
control (Figure 27).
9.16
Next, install the other SW605 wall control (sold separately)
into the wall box containing the load wire. Connect the
black wire of the SW605 wall control to the traveler wire(s)
already connected to the black wire (in the other wall box).
Secure with wire connectors supplied.
9.17
Connect one black wire of the SW605 wall control to the
“load” (black) wire and secure with wire connector
supplied.
9.18
Connect one black wire of the SW605 wall control to both
remaining traveler wires in the wall box and secure with
wire connector supplied.
Figure 35
Check to see that all connections are tight and that no
bare wires are visible at the wire connectors.
WARNING
!
STANDARD WIRING FOR EXISTING
3-WAY CONTROLS
EXISTING
WALL CONTROL
HOT
BLK
TRAVELER
WIRES
B
L
A
C
K
LOAD
SW605
FAN/LIGHT
WALL
CONTROL
BLK
B
L
A
C
K
LOAD
TRAVELER
WIRES
BLK
BLK
SW605
FAN/LIGHT
WALL
CONTROL
HOT
BLK
SECOND SW605
WALL CONTROL
PURCHASED
SEPARATELY
3-WAY WIRING DIAGRAM: RETROFIT