ETL Model No.: CF965

9. Wall Control Installation

SINGLE-POLE INSTALLATION

EXISTING
WALL CONTROL

HOT

BLK

NEUTRAL

BLACK

GROUND

L

O

A

D

B

L

A

C

K

RECEIVER LOCATED WITHIN 
THE MOTOR HOUSING

Figure 32

Turning off wall switch is not sufficient. To avoid possible

electrical shock, be sure electricity is turned off at the

main fuse or circuit breaker box before wiring. All wiring

must be in accordance with National and Local codes

and the ceiling fan must be properly grounded as a

precaution against possible electrical shock.

                           

WARNING

!

CAUTION: To reduce the risk of electrical shock,

disconnect the electrical supply circuit before

installing the fan, light kit or receiver.
NOTE: Make all wiring connections using wire

connectors (supplied). Make sure that all connections

are tight, including ground, and that no bare wire is

visible at the wire connectors, except for the ground

wire.

9.1

Disconnect  electrical  power  to  the  branch  circuit  at  the
circuit  breaker  or  fuse  box  before  attempting  to  install  the
ceiling fan SW605 wall control into the outlet box.

9.2

Remove  faceplate  and  screws  from  existing  wall  control.
Pull control out from the wall box. Determine the “hot” wire
and the “load” wire and disconnect these wires from control
(Figure  32).  Do  not  attempt  to  disconnect  any  wires  not
already connected to existing control.

Содержание Portland CF965BS00

Страница 1: ...25 9 Lbs Questions problems missing parts Before returning to the store call Emerson Electric Customer Service 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 www emersonfans com PORTLAND 54 Ceiling Fan Owner s Manual CF965BS00 Brushed Steel CF965VNB00 Venetian Bronze Model Numbers Español página 33 Français page 65 ...

Страница 2: ...ith an isolating wall control switch NOTE This fan is suitable for use with solid state speed controls WARNING To reduce the risk of fire or electrical shock this fan should only be used with fan speed control Model No FR 7861LMA 02 manufactured by Rhine Electric Co Ltd WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specificall...

Страница 3: ...sing call 1 800 654 3545 for replacement parts before proceeding 1 2 Remove the fan assembly from the protective plastic bag Place the fan assembly into the upper styrofoam with the bottom of the motor facing up The upper styrofoam serves as a holder for the fan during the first stages of assembly PACKAGE CONTENTS 1 2 3 5 6 8 4 10 9 7 Part Description Quantity A Fan Motor Assembly 1 B Ceiling Cano...

Страница 4: ...Your Emerson ceiling fan comes supplied with a Fan Light Remote Control which consists of a receiver mounted inside the ceiling cover of the fan motor housing This system allows you to regulate your ceiling fan speed and light ON OFF 4 ETL Model No CF965 2 Electrical Requirements Your new ceiling fan will require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circuit To reduce the ...

Страница 5: ...nch circuit at the circuit breaker or fuse box before attempting to install the ceiling fan mounting plate on the outlet box SPACER ATTACHMENT SCREW SHIPPING SPACER Figure 1 3 Ceiling Fan Assembly 3 2 Remove the shipping spacers and the spacer attachment screws from the motor before installation of blade assemblies Figure 1 Discard the spacers and spacer screws 10 32 x 1 4 SLOTTED PHILLIPS WASHER ...

Страница 6: ... 3 6 Remove one 8 32 x 1 1 4 slotted phillips head screw from the lower housing adapter plate reserve for later use Loosen the other two screws to assemble the light kit cover to the lower housing adapter plate Figure 4 3 7 Rotate the light kit cover to engage the two loosened screws in the two key hole slots Replace the 8 32 x 1 1 4 slotted phillips head screw removed previously and tighten all t...

Страница 7: ...pplied 4 5 downrod and install the longer downrod sold separately using the following instructions 3 9 Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod Figure 6 Remove the pin from the downrod then remove the hanger ball Retain the pin and hanger ball for reinstallation in Step 3 15 NOTE Do not loosen the screw holding the green groun...

Страница 8: ...L Model No CF965 It is critical that the setscrews are securely tightened Failure to verify that the setscrews are properly installed could result in the fan falling WARNING RETIGHTEN SETSCREWS 4 5 DOWNROD MOTOR COUPLING RETIGHTEN SETSCREWS 3 12 While pulling up on the 4 5 downrod retighten the two setscrews previously loosened in the motor coupling to secure the downrod into place Figure 9 NOTE T...

Страница 9: ...e top of the hanger ball Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball NOTE A loose setscrew could create fan wobble HANGER BALL DOWNROD ASSEMBLY 6 to 9 INCHES Figure 13 3 16 The fan comes with black and white leads that are 80 inches long Before installing the fan measure up approximately 6 to 9 inches above top of hanger ball downrod assembly ...

Страница 10: ...tor housing Figure 14 3 18 Rotate the four lower housing clamps over the inner edge of the upper glass Be sure to keep the rubber pad beneath each clamp to ensure proper clamping Tighten the four lower housing screws to secure the assembly Figure 14 RUBBER PAD AND CLAMP 4 LOWER HOUSING SCREWS 4 Figure 14 ...

Страница 11: ...lied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING The fan must be hung with at least 7 of clearance from floor to blades Figure 15 WARNING 4 1 Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box Figure...

Страница 12: ...NGER BRACKET HANGER BALL DOWNROD ASSEMBLY NOTE CEILING COVER SUPPL Y WIRES AND FAN WIRES OMITTED FOR CLARITY HANGER BRACKET HANGER BALL HANGER BALL GROOVE ANTI ROTATION TAB Figure 17 4 How to Hang Your Ceiling Fan Continued 4 2 Carefully lift the fan and seat the hanger ball downrod assembly on the hanger bracket that was just attached to the outlet box Figure 17 Be sure the groove in the ball is ...

Страница 13: ...insulation Securely connect wires with wire connectors supplied Figure 18 5 How to Wire Your Ceiling Fan To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring NOTE If you are not sure if the outlet box is grounded contact a licensed electrician for advice as it must be grounded for safe operation WARNING This product is designed to use only those p...

Страница 14: ...IRES Figure 21 5 4 After connections have been made turn leads upward and carefully push leads into the outlet box with the white and green leads on one side of the outlet box and position the black lead on the other side of the outlet box Figure 21 Check to see that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire Do not...

Страница 15: ...ceiling WARNING 5 6 Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover Figure 23 5 7 Secure the ceiling cover in place by sliding lockwashers over the threaded studs and installing the two knurled knobs supplied Figure 23 Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the c...

Страница 16: ...IPS HEAD SCREWS 3 LIGHT KIT ASSEMBLY LIGHT KIT COVER ROTATE LIGHT KIT ASSEMBLY CLOCKWISE TO ENGAGE Figure 25 To avoid possible fire or shock do not pinch wires between the light kit assembly and the light kit cover WARNING Check to see that all connections are tight and that no bare wire is visible at the wire connectors WARNING 6 1 Remove the pre installed wire nut from the fan motor assembly whi...

Страница 17: ... Fingerprints may result in shorter bulb life Remove fingerprints with rubbing alcohol GLASS SHADE Figure 27 6 10 Place the glass shade into the opening in the light kit assembly aligning the three flat areas on the top edge of the glass with the three raised dimples on the light kit assembly and turn the glass shade clockwise until it is fully seated Figure 27 NOTE Periodically check that the gla...

Страница 18: ...ent light connector to the motor assembly connector Figure 30 Screw the four 25 watt candelabra base bulbs into the AL100 accent light sockets Figure 30 25 WATT CANDELABRA BASE BULBS 4 AL100 ACCENT LIGHT SOCKETS 4 LIGHT KIT FAN MOTOR ACCENT LIGHT CONNECTORS Figure 30 CAUTION To reduce the risk of electrical shock disconnect the electrical supply circuit before installing the accent light kit 7 1 L...

Страница 19: ...ers numbered 1 2 3 4 and 5 on the switches are factory set in the ON up position Change the switch settings as follows NOTE Do not duplicate the code of an existing control of an installed ceiling fan within 100 feet 8 3 Slide the five switch levers in the SW605 wall control to your choice of ON up or down positions Use a ball point pen or small screwdriver and slide the levers firmly up or down 8...

Страница 20: ...f electrical shock disconnect the electrical supply circuit before installing the fan light kit or receiver NOTE Make all wiring connections using wire connectors supplied Make sure that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire 9 1 Disconnect electrical power to the branch circuit at the circuit breaker or fuse bo...

Страница 21: ...ve the SW605 wall control in OFF mode until fan installation is completed 9 7 The SW605 wall control is supplied with a white ivory and almond color switch covers Choose the finish that best suits your needs and snap the cover onto the SW605 wall control Figure 33 9 8 Install decorator wall plate using the two screws provided with wall plate Leave the SW605 wall control in OFF mode until fan insta...

Страница 22: ...taining the hot wire first Connect the black wire of the SW605 wall control to the hot wire Securely connect the wires with wire connectors supplied 9 13 Connect the other black wire of the SW605 wall control to both remaining traveler wires in the wall box and secure with wire connector supplied HOT BLACK SW605 FAN LIGHT WALL CONTROL TRAVELER WIRE BLK BLK LOAD BLACK GROUND NEUTRAL EMERSON EMERSON...

Страница 23: ...er SW605 wall control sold separately into the wall box containing the load wire Connect the black wire of the SW605 wall control to the traveler wire s already connected to the black wire in the other wall box Secure with wire connectors supplied 9 17 Connect one black wire of the SW605 wall control to the load black wire and secure with wire connector supplied 9 18 Connect one black wire of the ...

Страница 24: ...iling fan will automatically begin high speed conditioning of the motor During conditioning the electronic motor control software is calculating speeds for the 2nd through 5th speed settings based on the blades that were installed on the fan 10 2 The fan will run for approximately 2 minutes in the upward direction then reverse direction to down flow and run an additional 2 minutes When conditionin...

Страница 25: ...tensity 11 3 To turn the uplight on press and release the button The light will turn on at the light intensity previously selected The intensity will go up and down while the button is held Release the button at the desired intensity 11 4 Your SW605 wall control comes complete with your choice of three wall cover plates ivory white and light almond 11 5 If airflow is desired in the opposite direct...

Страница 26: ...nst harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or t...

Страница 27: ...nd carefully reassemble the cover inside the light kit housing adapter WARNING Make sure main power is turned OFF 3 Fan wobbles 1 Blades are not tightly fastened to the fan 1 Check all blade screws for tightness excessively WARNING Make sure main power is turned OFF 2 Fan blades out of balance 2 Interchange an adjacent side by side blade pair to redistribute the weight Locate the supplied blade ba...

Страница 28: ...28 ETL Model No CF965 16 Repair Parts 18 17 1 15 2 3 4 20 6 5 11 23 13 12 8 9 22 7 19 21 10 14 24 21 16 ...

Страница 29: ...64604 VNB 7 Control Receiver DC Motor 1 764087 1 764087 1 8 Light Kit Cover 1 764615 BS 764615 VNB 9 Light Kit Assembly 1 764682 WW 764682 WW 10 50W Mini Halogen Base Bulbs 3 11 Lower Glass Shade 1 764618 OM 764618 OM 12 Fan Blade Flanges 5 764611 BS 764611 VNB 13 Fan Blades 5 764613 DM WA 764613 DM WA 14 SW605 Wall Control w Hardware 1 SW605 SW605 Parts Bag Containing 764619 CRM 764619 BLOX 15 Th...

Страница 30: ...30 ETL Model No CF965 Notes ...

Страница 31: ... can call Emerson Customer Service at 1 800 237 6511 to obtain a return authorization and service identification tag In order for us to confirm that your Emerson Ceiling Fan is still under warranty please retain your receipt or other proof of purchase and have that information readily available when returning your Emerson Ceiling Fan to your place of purchase or upon calling Emerson Customer Servi...

Страница 32: ... Service 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 www emersonfans com Retain this manual for future use Air Comfort Products DIVISION OF EmErSON ElEctrIc cO 8100 W Florissant St louis mO 63136 Part No F40BP74980000 Form No BP7498 Revision 150123 ETL Model No CF965 Printed in China 01 15 ...

Отзывы: