WARNING
Do not proceed with removal of the jet pump
from connecting piping unless the jet pump has
been relieved of all pressure or vacuum, has
been allowed to reach ambient temperature and
has been drained or purged of all fluids. Failure
to follow these instructions may cause a sudden
release of pressure resulting in personal injury or
property damage.
WARNING
Jet pumps manufactured in PVC, molded
polypropylene or Kynar
®
materials are of
one-piece construction and are not intended
for disassembly or field repair, see Figure 1.
PVC, molded polypropylene or Kynar
®
units which
have been damaged, worn out or have developed
leaks should be taken out of service, disposed
of in a safe manner determined by the user, and
replaced. Attempted repair of defective PVC,
molded polypropylene or Kynar
®
one-piece units
may cause severe personal injury or property
damage.
8 DISPOSAL AT END OF USEFUL LIFE
Penberthy jet pumps are used in a variety of
fluid applications. By following the appropriate
federal and industry regulations, the user
must determine the extent of preparation and
treatment the jet pump must incur before its
disposal. A Material Safety Data Sheet (MSDS)
may be required before disposal services accept
certain components.
Metal, glass and polymers should be recycled
whenever possible. Refer to order and
relevant technical data sheet for materials of
construction.
9 TELEPHONE ASSISTANCE
If you are having difficulty with your jet pump,
contact your local Penberthy distributor. So that
we may assist you more effectively, please have
as much of the following information available
as possible when you call:
- Model number
- Name of the company from whom you
purchased the jet pump
- Invoice number and date
- Process conditions (pressure, flow rates, tank
shape, etc.)
- A brief description of the problem
- Trouble shooting procedures that failed
If attempts to solve your problem fail, you may
request to return your jet pump to the factory
for intensive testing. You must obtain a Return
Authorization (R.A.) number from Emerson
before returning anything. Failure to do so will
result in the unit being returned to you without
being tested, freight collect. To obtain an R.A.
number, the following information (in addition to
that above) is needed:
- Reason for return
- Person to contact at your company
- 'Ship-to' address
There is a minimum charge for evaluation
of non-warranty units. You will be contacted
before any repairs are initiated should the cost
exceed the minimum charge. If you return a
unit under warranty, but it is not defective, the
minimum charge will apply.