2 INTRODUCTION

2.1 Features and specifications

Penberthy molded and bar stock plastic 
material jet pumps are designed to handle 
corrosive fluids where their corrosion 
resistance is superior to that of standard 
metal construction units. For specific 
recommendation on temperature/corrosion 
resistance of plastic material, consult the 
relevant technical data sheet or a product 
proposal for the particular application.

2.2 Design ratings at maximum and minimum 
operating temperatures (see Table 1)

To determine the maximum allowable working 
pressure for a specific temperature within the 
design limits stated in Table 1, the user should 
refer to relevant technical data sheets or, when 
provided, the specifically stated design limits on 
a product proposal.

TABLE 1 - DESIGN RATINGS AT MAXIMUM AND MINIMUM OPERATING TEMPERATURES

Material

Bodies

PVC

100 psig [690 kPaG] at + 70°F [ 21°C]
20 psig [140 kPaG] at + 140°F [ 60°C]

Kynar

®

100 psig [690 kPaG] at + 70°F [ 21°C]
20 psig [140 kPaG] at + 275°F [135°C]

Polypropylene

100 psig [690 kPaG] at + 70°F [ 21°C]
25 psig [172 kPaG] at + 170°F [ 77°C]

1 ABOUT THE MANUAL

This manual has been prepared as an aid and 
guide for personnel involved in installation or 
maintenance. All instructions must be read and 
understood thoroughly before attempting any 
installation, operation or maintenance.

IMPORTANT

Emerson does not have any control over the 
manner in which its jet pump is handled, installed 
or used. Emerson cannot and will not guarantee 
that a jet pump is suitable for or compatible with 
the user's specific application.

WARNING

Failure to follow any instruction may cause a 
malfunction of the jet pump resulting in a sudden 
release of pressure, severe physical injury or 
property damage.

2.3 Application data

Models LL, LM and LH are liquid operated 
jet pumps for pumping liquids against low, 
medium and high discharge pressures 
respectively.

Models LM and ELL are liquid operated jet 
pumps for exhausting gases. Model ELL is self 
priming and has greater suction capacity at 
vacuum.

Models GL and GH are gas operated jet pumps 
for pumping gases against low and high 
discharge pressures respectively.

Note:

 For specific application data within 

the ranges stated in Table 1, the user should 
consult the product proposal for the specific 
model and size jet pump, or should request the 
supply of the applicable technical data sheet.

WARNING

Under no circumstances should these design 
ratings or application data be exceeded. 
Exceeding design ratings or application data may 
cause severe physical injury or property damage.

3 INSPECTION AND PERFORMANCE 
CONFIRMATION

3.1 Receiving inspection

Upon receipt of the jet pump, check all 
components carefully for damage incurred in 
shipping. If damage is evident or suspected, 
do not attempt installation. Notify the carrier 
immediately and request a damage inspection.

3.2 User's rating inspection

The user should confirm that:
1.  The jet pump size and model designation 

(stamped on delivery jet or label) conforms 
to the description on the user's purchase 
order.

2.  The operating conditions described in 

the purchase order agree with the actual 
operating conditions at the installation site.

3.  The actual operating conditions at the 

installation site are within the application 
data shown on the relevant technical data 
sheet or product proposal referred to above.

4.  The materials of construction of the 

jet pump are compatible with both the 
contained fluid and the surrounding 
atmosphere in the specific application.

Kynar

®

 is the registered trademark of Arkema 

polyvinylidene fluoride (PVDF) resin. 

IMPORTANT

If the size, model or performance data of the jet 
pump as received does not conform with any of 
the criteria above, do not proceed with installation. 
Contact an authorized Penberthy distributor for 
assistance.

Содержание Penberthy LL

Страница 1: ...ponsible for damage or injury caused to other products buildings personnel or property by reason of the installation or use of its products This is Emerson s sole warranty and in lieu of all other warranties expressed or implied which are hereby excluded including in particular all warranties of merchantability or fitness for a particular purpose This document and the warranty contained herein may...

Страница 2: ...n data Models LL LM and LH are liquid operated jet pumps for pumping liquids against low medium and high discharge pressures respectively Models LM and ELL are liquid operated jet pumps for exhausting gases Model ELL is self priming and has greater suction capacity at vacuum Models GL and GH are gas operated jet pumps for pumping gases against low and high discharge pressures respectively Note For...

Страница 3: ...rime a centrifugal pump c Throttle suction flow 8 When a gas operated jet pump is used to lift liquids by suction or vacuum the jet pump should be located as close to the level of the liquid as practical However any liquid entrained into the jet pump will cause the jet pump to stop pumping resulting in a possible suction flow reversal 9 Discharge piping should be sized as short as possible and wit...

Страница 4: ...ed experienced personnel who are familiar with this equipment and have read and understood all the instructions in this manual DO NOT proceed with any maintenance unless the jet pump has been relieved of all pressure or vacuum has been allowed to reach ambient temperature and has been drained or purged of all fluids Failure to follow these instructions may cause a sudden release of pressure result...

Страница 5: ...cur before its disposal A Material Safety Data Sheet MSDS may be required before disposal services accept certain components Metal glass and polymers should be recycled whenever possible Refer to order and relevant technical data sheet for materials of construction 9 TELEPHONE ASSISTANCE If you are having difficulty with your jet pump contact your local Penberthy distributor So that we may assist ...

Страница 6: ... logo are trademarks and service marks of Emerson Electric Co All other marks are the property of their respective owners The contents of this publication are presented for informational purposes only and while every effort has been made to ensure their accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or their ...

Отзывы: