DISCONTINUED
PRODUCT
Site Planning Data, Series 610, 100-225kVA, Single-Module Systems
65
A
PPENDIX
A-S
ITE
P
LANNING
D
A
TA
, S
ERIE
S
610, 100-225
K
VA
, S
INGLE
-M
ODULE
S
YS
TE
M
S
Notes for T
ables
6 -
8
1.
Nominal
rectifier AC
input
current
(c
on
si
de
re
d c
on
ti
n
u
ou
s)
is
b
as
ed
o
n
f
u
ll
ra
ted
output
load.
M
axim
u
m
cur
rent
in
cludes
nomina
l input curr
ent and
max
imum bat
tery
rec
h
ar
ge c
u
rr
ent (con
sider
ed nonc
ont
inu
ous
). Con
tin
uou
s
and
nonc
onti
nuous
cu
rr
ent
limits
a
re
defined
in
NEC
10
0.
Maxi
mum
input
cu
rr
en
t
is
c
on
tr
ol
le
d
by
current limit
s
etting which is adj
u
st
abl
e.
Values
shown
for
ma
ximum sett
ing
a
re 125
% of
nominal input c
u
rr
ent
. St
anda
rd
fact
ory
s
et
tin
g is 11
5%.
2.
Nominal AC output current
(consi
de
red
cont
inu
ous
)
is
b
ased
on
ful
l r
ated
output load. Max
imum
cu
rr
ent inc
ludes
nominal
output
current
and
ov
er
lo
ad
c
u
rr
en
t f
or
1
0 m
in
u
te
s.
3.
Bypass AC input current
(considered
continuous) is bas
ed
on
full rat
ed
output load.
4.
F
ee
de
r p
ro
te
ct
io
n
(
by
o
th
er
s
in
e
xt
ern
al e
qu
ipme
n
t)
for
r
ect
ifier
AC
inpu
t
and bypass AC
input is reco
m
m
ended to
be
provided by se
par
ate o
ver
cu
rr
ent
protection
devices.
5.
UPS out
pu
t load ca
bles mu
st be ru
n in
s
epara
te con
du
it fr
om
in
put
c
abl
es.
6.
Power
c
able from modu
le
DC bu
s to
ba
tt
er
y sh
ould be siz
ed for a tota
l
m
ax
imu
m
2.
0
vo
lt
li
n
e
dr
op
(
po
w
er
c
ab
le
d
ro
p
pl
u
s r
et
u
rn
c
ab
le
d
ro
p a
s
meas
ur
ed at
t
h
e module) at max
imum disc
har
ge curr
ent
.
7.
G
rou
ndin
g con
duc
tor
s to be sized per
N
E
C
2
50
-1
22
. N
eu
tr
al
c
on
du
ct
or
s
to
b
e
si
zed
for
full
c
apa
cit
y—per NEC
310-1
5 (b)(4)—for
sy
stems
wi
th 4
-wir
e loads
an
d
h
alf c
apac
ity for sy
stem
s wit
h
3-wi
re loads.
8.
Rec
tifier
AC
In
put:
3-pha
se,
3-wir
e,
plus
g
rou
nd
AC O
u
tpu
t to Loa
d: 3-ph
ase,
3
-
or
4
-w
ir
e, plu
s gr
ou
nd
Bypass AC
Input:
3-phase,
3-
or
4-wire
, plu
s
gr
oun
d
Modu
le DC Inpu
t from Bat
tery
: 2-w
ire (posit
ive an
d
n
egat
ive),
plu
s gr
oun
d
9.
A
ll
w
ir
in
g
is
t
o
be
in
a
cc
or
da
n
ce
w
ith Na
tiona
l and Loca
l E
lectr
ic
al Codes.
10.
M
in
imum overhead
cl
eara
nc
e
is
2
ft.
(0.
6m)
above
th
e
UPS
.
11
.
T
op
an
d
bott
om
cabl
e
en
try
t
h
ro
ug
h
remov
able
ac
ces
s
plates
on
s
tan
dard
si
ze
cabinets only.
Top cable entry on
ly
on Spac
eSav
er ca
bin
ets, wh
ich
are
8"
(2
0c
m
)
n
ar
row
er
tha
n
st
anda
rd
si
ze
ca
bi
n
et
s.
S
pac
eS
av
er
ca
bi
n
et
s
ar
e
av
aila
ble on all 100
-125kVA
u
n
it
s and on 15
0-225
kV
A
u
n
it
s th
at hav
e
eit
h
er
60
0 or
480V
AC ou
tpu
t.
Cu
t ac
cess
pl
ates to su
it con
dui
t
size.
12.
C
ontr
ol wir
in
g
and po
wer
cables
mus
t
be ru
n
in s
eparate c
ondu
its
. Control
wir
ing
mus
t b
e s
tra
nded
ti
n
ned
con
du
cto
rs
.
13
.
7%
m
ax
im
u
m
r
ef
le
cte
d
in
pu
t
h
ar
m
on
ic
c
u
rr
en
t
an
d
0.
92
la
gg
in
g
in
pu
t
po
w
er
factor at
full load wit
h
optional input filter.
Содержание Liebert Series 610
Страница 6: ...DISCONTINUED PRODUCT iv ...
Страница 42: ...DISCONTINUED PRODUCT Installation Drawings 36 Figure 17 Battery power pack system 88 797616 03 Rev 08 ...
Страница 43: ...DISCONTINUED PRODUCT Installation Drawings 37 Figure 18 Battery power pack Size A 88 797616 01 Rev 10 ...
Страница 70: ...DISCONTINUED PRODUCT Installation Drawings 64 ...
Страница 75: ...DISCONTINUED PRODUCT ...