background image

5

WARNING:  For your own safety, do not
use humidifier if any parts are damaged
or missing.

Step 1
Place humidifier on a flat level surface in area
of house where most humidity is needed, or
one which would likely result in moist air
being circulated throughout the house such
as near a cold air return. Placing the unit
level is very important if the humidifier is
located on carpeting.
NOTE: The 13 gallon humidifier contains
water bottles. The weight of the bottles in
the front of the cabinet may sink the front
casters deeper in the carpet. This will
keep the water level forward in the cabi-
net. The water level float (located at the
rear of the cabinet) may not sense the
water and the fill light will be on and the
unit will not energize. If this happens, the
unit will need to be leveled in order for the
humidifier to be energized.
NOTE: It may be necessary to purchase lev-
eling coasters from your local hardware store.
The coasters should be positioned under the
front two casters of the humidifier.
Moist air (humidity) produced will disperse
into the whole house, but area closest to unit
will have the highest humidity. If the unit is
positioned close to a window, condensation
may form on the window pane. If this is not

Location Instructions

Water Fill

WARNING: To reduce the risk of shock,
always unplug humidifier before filling,
cleaning, or servicing.

WARNING: To reduce the risk of fire or
shock hazard, do not pour or spill water
into control or motor area. Close the
control cover. If controls get wet, let
them dry completely and have unit
checked by authorized service person-
nel before plugging in.

This humidifier is designed to be used with
the two water bottles that are located under
the pivoting lid. 

Pivoting Lid
Removed for
Clarity

At Least
2" From Wall

appropriate the unit should be repositioned in
another location.
NOTE: Due to release of cool, moist air from
humidifier, it is best to direct air away from
home thermostat and hot air registers. It is
best to position humidifier next to an inside
wall. Hot air registers and cold air from out-
side walls can affect the efficiencies of the
controls. Unit should not be placed where
warm air from a hot air register blows directly
on unit.
Step 2
The humidifier should be positioned with the
back (cord exit side), at least 2 inches away
from the wall. Air needs to enter through lou-
vers in the back of the cabinet in order for the
humidifier to operate at peak efficiency.

Water
Bottles

Cabinet

Front of Humidifier

Fan Assembly

HD1300 3 US manual  11/14/00  1:40 PM  Page 5

Содержание HD13002

Страница 1: ...AUTION Read all instructions carefully before installation Save this Owner s Manual for future reference Model No HD1300 3 MoistAIR HD1300 Evaporative Console Humidifier Owner s Manual EMERSON HD1300 3 US manual 11 14 00 1 40 PM Page 1 ...

Страница 2: ...STRUCTIONS 2 Limited Warranty All products covered by this Owner s Manual are warranted against defects in workmanship and materials for one year from the date of sale except for motors which are warranted for two years This warranty does not apply to damage from accident misuse or alteration nor where the connected voltage is more than 5 above the nameplate voltage nor to the equipment improperly...

Страница 3: ...itre Output 24 hrs 13 Capacity of Bottles 2 3 8 Gallons Each Sq Ft Coverage 2 700 Fan SpeedsVariable Filters 4 HDC 12 Fill Light Yes Auto Humidistat Yes Auto Shut Off Yes Dry Out Manual Controls Rotary CUL Listed Yes AHAM Certified Yes Volts 120 A C Hertz 60 Amps 2 88 Watts 165 Based on an area with average insulation and an 8 foot ceiling HD1300 3 US manual 11 14 00 1 40 PM Page 3 ...

Страница 4: ... to order Under no circumstances should you use water treatment prod ucts for Roto belt or Ultrasonic humidi fiers manual for proper usage The packaging material is located under the fan assembly Remove the packaging material and discard Humidified Air is Then Released Through the Top Dry Air Enters Through the Rear CAUTION Keep your humidifier clean While humidifiers do not cause colds some studi...

Страница 5: ...ow condensation may form on the window pane If this is not Location Instructions Water Fill WARNING To reduce the risk of shock always unplug humidifier before filling cleaning or servicing WARNING To reduce the risk of fire or shock hazard do not pour or spill water into control or motor area Close the control cover If controls get wet let them dry completely and have unit checked by authorized s...

Страница 6: ...e leaks by performing the following 1 Grasp bottle handle and hold the bottle upright over a sink 2 Press up on valve cap plunger for about one second to let out a little water 3 Release the plunger 4 Listen for air bubbles Look for leaks around E Z Fill Side Cap 5 If you hear air bubbles or see leaks retighten E Z Fill Side Cap and repeat steps 1 4 NOTE Repeat for other bottle If either fill cap ...

Страница 7: ...trol The unit is adjusted from OFF to high to low with a variable speed control The higher the air flow speed the more water is evaporated and released into the air MIN speed is the quietest and is provided for con ditions that may not require as high an evap oration rate Fill Light When the unit has a small amount of water left in it the fill light will come on and the unit will automatically shu...

Страница 8: ...nger forms Step 5 If humidifier stops running and the Fill Light is not illuminated the humidity level is at the normal requirements for that setting or it is adjusting to the home conditions The table below shows recommended indoor humidity levels The figure below shows approximate relative humidity percentages which corre spond to the various settings of the Humidity Control When Outdoor Recomme...

Страница 9: ...e not susceptible to water damage i e kitchen or bath areas 2 Open the pivoting lid and remove water bottles and set aside Grasp the fan assembly front centre and rear centre Lift off and set aside on a clean flat surface The filter assemblies are now accessible 3 Lift filter housings out of cabinet and place where you may work on them comfortably With a soft absorbent cloth remove any remaining w...

Страница 10: ...e of the cabinet Be sure that spring tabs of filter hous ings are towards front of cabinet Align the lower portion of the filter assembly over the six ribs located at the bottom rear of the humidifier cabi net f Position fan assembly onto the cabinet Make sure the fan venturi lowest cylin der section below the fan is placed inside the filter housing g Replace water bottles h Close the pivoting lid...

Страница 11: ...center Lift off and set aside on a clean flat surface The filter housings are now accessible b Before removing the internal parts of the humidifier cabinet we recommend moving the humidifier to an area where floor cov erings are not susceptible to water dam age i e kitchen or bath area Lift the filter housing assemblies out of the cabinet and set to the side c Remove the water level float from the...

Страница 12: ...allon of water Let solution stay 20 minutes swishing every few minutes Wet all surfaces normally exposed to water 2 Empty humidifier cabinet after 20 min utes Rinse with water until bleach smell is gone Allow unit to dry out completely 3 Water bottles should be cleaned in same manner End of Season Maintenance 1 Follow bi weekly maintenance instructions at end of humidification season 2 Remove and ...

Страница 13: ...t completely Bottles continue to empty Unit is not emptying during use Unit runs and shuts off before bottles are empty REMEDY Raise humidistat setting if desired Check 120 volt source for power Free float from obstruction Slide float retainer down to lowest position in slot at back of cabi net See diagram on page 11 A small amount of water remains in the cabinet after the Fill Light comes on Chec...

Страница 14: ...arts PARTS LIST FOR EMERSON HUMIDIFIERS MODEL NO HD1300 3 19 20 15 14 16 13 12 33 11 9 10 8 7 6 5 4 35 34 17 3 2 1 18 21 22 23 24 24 25 25 32 26 27 27 22 31 28 30 29 29 HD1300 3 US manual 11 14 00 1 40 PM Page 14 ...

Страница 15: ... 1 Cap Valve Assembly 20 828199 5 Cabinet 21 823726 2 Rail Kick 22 Screw Pan Hd Ty AB 10 x 3 4 23 822120 Caster Twin Wheel 24 823849 Support Filter Lower 25 HDC 12 Filter Evaporative 26 828197 Support Upper L H Filter 27 823735 Support Motor 28 822405 1 Motor Single Speed 29 822406 1 Fan 30 816069 2 Screw Pan Hd AB 6 x 1 3 4 31 822405 2 Motor 32 828196 Support Upper R H Filter 33 821904 Cord w Plu...

Страница 16: ...c Co Part No SP6305 Form No SP6305 1 Printed in Canada 09 00 FOR PARTS OR TECHNICAL HELP CALL 800 654 3545 Please have complete model number 8100 W Florissant St Louis Mo 63136 TM HD1300 3 US manual 11 14 00 1 40 PM Page 16 ...