Replacement and Care of Filters (continued)
c. Install new filters in the filter housing
track with the glue beads of the wicking
pad to the inside of the filter housing.
d. Return the top cover of the filter hous-
ing by installing the cover over the fixed
tabs on the rear of the lower filter hous-
ing and pivoting the cover down over
the top of the filters. Snap the cover
over the two spring tabs.
e. Replace the filter housing in the cabi-
net. Note: There is a left and a right fil-
ter housing. There is also a front and
back orientation. To position the filter
housings correctly:
• Make sure the two indents in the
cylinder section of the top covers are
positioned towards the centre of the
cabinet.
• Be sure that spring tabs of filter hous-
ings are towards front of cabinet.
• Align the lower portion of the filter
assembly over the six ribs, located at
the bottom rear of the humidifier cabi-
net.
f. Position fan assembly onto the cabinet.
Make sure the fan venturi (lowest cylin-
der section below the fan) is placed
inside the filter housing.
g. Replace water bottles.
h. Close the pivoting lid on the fan assem-
bly.
i. The unit is ready for use or to be stored
away for the next season.
NOTE: For correct operation of the filter
housing assembly, filters must be fully con-
tained inside the flange of the top cover.
Spring Tabs
Fixed Tabs
Filter
Housing
Front of
Humidifier
Rear of
Humidifier
Indents
Towards
Centre
of Cabinet
Top
Cover
Flat Portion of Filter Housing
Towards Back of Cabinet
Indents Toward Centre of Cabinet
Step 4.e.