background image

Safety Signal Words

DANGER: means if the safety information is
not followed someone will be seriously
injured or killed.
WARNING: means if the safety information is
not followed someone could be seriously
injured or killed.
CAUTION: means if the safety information is
not followed someone may be injured.
1. To reduce the risk of fire or shock hazard,

plug humidifier directly into a 120V, A.C.
electrical outlet. Do not use extension
cords.

2.  Keep the electric cord out of traffic areas.

To reduce the risk of fire hazard, never
put the electric cord under rugs, near heat
registers, radiators, stoves or heaters.

3.  Always unplug the humidifier before mov-

ing it, removing the fan assembly section,
before cleaning, or whenever the humidifi-
er is not in service.

4.  Keep the humidifier clean.
5.  Do not put foreign objects inside the

humidifier.

6.  Never use your humidifier while any part

is missing or damaged in any manner.

7.  To reduce the risk of electrical hazard or

damage to humidifier, do not tilt, jolt or tip
humidifier over while unit is running.

8. To reduce the risk of damage to humidifi-

er, unplug humidifier when water bottles
are empty or when the humidifier is not in
use.

9. To reduce the risk of accidental electrical

shock, do not touch the cord or controls with
wet hands.

10. Note the warning label shown below.

WARNING: To reduce the risk of fire, electric
shock, or injury always unplug before filling,
servicing or cleaning.

GENERAL SAFETY INSTRUCTIONS

2

Limited Warranty

All products covered by this Owner’s Manual are warranted against defects in
workmanship and materials for one year from the date of sale except for motors,
which are warranted for two years. This warranty does not apply to damage from
accident, misuse or alteration nor where the connected voltage is more than 5%
above the nameplate voltage, nor to the equipment improperly installed or wired or
maintained in violation of this Owner’s Manual. No other written or oral warranty
applies. No employee, agent, dealer or other person is authorized to give any war-
ranties on behalf of Emerson Electric.
The customer shall be responsible for all costs incurred in the removal or reinstalla-
tion and shipping of the product for repairs. Within the limitations of this warranty,
inoperative units should be returned, freight prepaid to the nearest Emerson autho-
rized service centre, or the Emerson Electric Co. Service Centre, and we will repair
or replace, at our option, at no charge to you with return freight paid by Emerson. It
is agreed that such repair or replacement is the exclusive remedy available from
Emerson Electric Co. and that Emerson Is Not Responsible For Damages Of
Any Kind, Including Incidental And Consequential Damage. 
Some states do
not allow the exclusion or limitation of incidental or consequential damages, so the
above exclusion or limitation may not apply to you.
The warranty gives you specific legal rights, and you may also have other rights
which vary from state to state.
For the address of your nearest authorized service centre, call (901) 642-1120.

HD1300 3 US manual  11/14/00  1:40 PM  Page 2

Содержание HD13002

Страница 1: ...AUTION Read all instructions carefully before installation Save this Owner s Manual for future reference Model No HD1300 3 MoistAIR HD1300 Evaporative Console Humidifier Owner s Manual EMERSON HD1300 3 US manual 11 14 00 1 40 PM Page 1 ...

Страница 2: ...STRUCTIONS 2 Limited Warranty All products covered by this Owner s Manual are warranted against defects in workmanship and materials for one year from the date of sale except for motors which are warranted for two years This warranty does not apply to damage from accident misuse or alteration nor where the connected voltage is more than 5 above the nameplate voltage nor to the equipment improperly...

Страница 3: ...itre Output 24 hrs 13 Capacity of Bottles 2 3 8 Gallons Each Sq Ft Coverage 2 700 Fan SpeedsVariable Filters 4 HDC 12 Fill Light Yes Auto Humidistat Yes Auto Shut Off Yes Dry Out Manual Controls Rotary CUL Listed Yes AHAM Certified Yes Volts 120 A C Hertz 60 Amps 2 88 Watts 165 Based on an area with average insulation and an 8 foot ceiling HD1300 3 US manual 11 14 00 1 40 PM Page 3 ...

Страница 4: ... to order Under no circumstances should you use water treatment prod ucts for Roto belt or Ultrasonic humidi fiers manual for proper usage The packaging material is located under the fan assembly Remove the packaging material and discard Humidified Air is Then Released Through the Top Dry Air Enters Through the Rear CAUTION Keep your humidifier clean While humidifiers do not cause colds some studi...

Страница 5: ...ow condensation may form on the window pane If this is not Location Instructions Water Fill WARNING To reduce the risk of shock always unplug humidifier before filling cleaning or servicing WARNING To reduce the risk of fire or shock hazard do not pour or spill water into control or motor area Close the control cover If controls get wet let them dry completely and have unit checked by authorized s...

Страница 6: ...e leaks by performing the following 1 Grasp bottle handle and hold the bottle upright over a sink 2 Press up on valve cap plunger for about one second to let out a little water 3 Release the plunger 4 Listen for air bubbles Look for leaks around E Z Fill Side Cap 5 If you hear air bubbles or see leaks retighten E Z Fill Side Cap and repeat steps 1 4 NOTE Repeat for other bottle If either fill cap ...

Страница 7: ...trol The unit is adjusted from OFF to high to low with a variable speed control The higher the air flow speed the more water is evaporated and released into the air MIN speed is the quietest and is provided for con ditions that may not require as high an evap oration rate Fill Light When the unit has a small amount of water left in it the fill light will come on and the unit will automatically shu...

Страница 8: ...nger forms Step 5 If humidifier stops running and the Fill Light is not illuminated the humidity level is at the normal requirements for that setting or it is adjusting to the home conditions The table below shows recommended indoor humidity levels The figure below shows approximate relative humidity percentages which corre spond to the various settings of the Humidity Control When Outdoor Recomme...

Страница 9: ...e not susceptible to water damage i e kitchen or bath areas 2 Open the pivoting lid and remove water bottles and set aside Grasp the fan assembly front centre and rear centre Lift off and set aside on a clean flat surface The filter assemblies are now accessible 3 Lift filter housings out of cabinet and place where you may work on them comfortably With a soft absorbent cloth remove any remaining w...

Страница 10: ...e of the cabinet Be sure that spring tabs of filter hous ings are towards front of cabinet Align the lower portion of the filter assembly over the six ribs located at the bottom rear of the humidifier cabi net f Position fan assembly onto the cabinet Make sure the fan venturi lowest cylin der section below the fan is placed inside the filter housing g Replace water bottles h Close the pivoting lid...

Страница 11: ...center Lift off and set aside on a clean flat surface The filter housings are now accessible b Before removing the internal parts of the humidifier cabinet we recommend moving the humidifier to an area where floor cov erings are not susceptible to water dam age i e kitchen or bath area Lift the filter housing assemblies out of the cabinet and set to the side c Remove the water level float from the...

Страница 12: ...allon of water Let solution stay 20 minutes swishing every few minutes Wet all surfaces normally exposed to water 2 Empty humidifier cabinet after 20 min utes Rinse with water until bleach smell is gone Allow unit to dry out completely 3 Water bottles should be cleaned in same manner End of Season Maintenance 1 Follow bi weekly maintenance instructions at end of humidification season 2 Remove and ...

Страница 13: ...t completely Bottles continue to empty Unit is not emptying during use Unit runs and shuts off before bottles are empty REMEDY Raise humidistat setting if desired Check 120 volt source for power Free float from obstruction Slide float retainer down to lowest position in slot at back of cabi net See diagram on page 11 A small amount of water remains in the cabinet after the Fill Light comes on Chec...

Страница 14: ...arts PARTS LIST FOR EMERSON HUMIDIFIERS MODEL NO HD1300 3 19 20 15 14 16 13 12 33 11 9 10 8 7 6 5 4 35 34 17 3 2 1 18 21 22 23 24 24 25 25 32 26 27 27 22 31 28 30 29 29 HD1300 3 US manual 11 14 00 1 40 PM Page 14 ...

Страница 15: ... 1 Cap Valve Assembly 20 828199 5 Cabinet 21 823726 2 Rail Kick 22 Screw Pan Hd Ty AB 10 x 3 4 23 822120 Caster Twin Wheel 24 823849 Support Filter Lower 25 HDC 12 Filter Evaporative 26 828197 Support Upper L H Filter 27 823735 Support Motor 28 822405 1 Motor Single Speed 29 822406 1 Fan 30 816069 2 Screw Pan Hd AB 6 x 1 3 4 31 822405 2 Motor 32 828196 Support Upper R H Filter 33 821904 Cord w Plu...

Страница 16: ...c Co Part No SP6305 Form No SP6305 1 Printed in Canada 09 00 FOR PARTS OR TECHNICAL HELP CALL 800 654 3545 Please have complete model number 8100 W Florissant St Louis Mo 63136 TM HD1300 3 US manual 11 14 00 1 40 PM Page 16 ...

Отзывы: