background image

Type SR5 

The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective owners. Fisher is a mark owned by Fisher Controls, Inc., 

a business of Emerson Process Management.

The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties 

or guarantees, express or implied, regarding the products or services described herein or their use or applicability. We reserve the right to modify or improve the designs or specifications 

of such products at any time without notice.

Emerson Process Management does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any 

Emerson Process Management product remains solely with the purchaser.

©Fisher Controls International, Inc., 2004, 2006; All Rights Reserved

Industrial

USA - Headquarters

McKinney, Texas 75070 USA

Tel: 1-800-558-5856

Outside U.S. 1-469-293-4201
Asia-Pacific

Shanghai, China 201206

Tel: 86-21-5899 7887

Europe

Bologna, Italy 40013

Tel: 39 051 4190611

Natural gas technologies

USA - Headquarters

McKinney, Texas 75070

Tel: 1-800-558-5856

Outside U.S. 1-469-293-4201
Asia-Pacific

Singapore, Singapore 128461

Tel: +65 6777 8211
Europe

Bologna, Italy 40013

Tel: 39 051 4190611

Gallardon, France 28320

Tel: +33 (0)2 37 33 47 00

Industrial/high Purity

TESCOM

Elk River, Minnesota 55330 USA

Tel: 1-763-241-3238

Selmsdorf, Germany 23923

Tel: +49 (0) 38823 31 0

For further information visit www.emersonprocess.com/regulators

Содержание Fisher SR5

Страница 1: ...Maximum Inlet Pressure 14 5 bar at 65 C 210 psig at 150 F 12 4 bar at 135 C 180 psig at 275 F 11 bar at 204 C 160 psig at 400 F Maximum Outlet Pressure 10 3 bar at 65 C 150 psig at 150 F 8 62 bar at 135 C 125 psig at 275 F 7 58 bar at 204 C 110 psig at 400 F Proof Test Pressure All Pressure Retaining Components have been proof tested per Directive 97 23 EC Annex 1 Section 7 4 Outlet Pressure Range...

Страница 2: ...or inlet pressure is greater than the safe working pressure of the downstream equipment Regulator operation below the maximum pressure limitations does not preclude the possibility of damage from external sources or debris in the line The regulator should be inspected for damage after any overpressure condition Startup The regulator is factory set at approximately the midpoint of the spring range ...

Страница 3: ...escription 1 Body 2 Plug metal seat 3 Plug O Ring 4 Diaphragm Plate O Ring 5 Piston Ring 6 Diaphragm Gasket 7 Diaphragm 8 Lower Spring Seat 9 Guide Ring 10 Diaphragm Plate 11 Upper Spring Seat 12 Spring 13 Inner Spring 14 Spring Case 15 Bolted Clamp 16 Hex Nut 17 Hex Nut 18 Adjusting Screw 19 Closing Cap 22 Locking Lever 23 Flat Washer 24 Lock Washer 26 Upper Plug 27 Lower Plug 28 Soft Seat 30 Rin...

Страница 4: ...ility for the selection use or maintenance of any product Responsibility for proper selection use and maintenance of any Emerson Process Management product remains solely with the purchaser Fisher Controls International Inc 2004 2006 All Rights Reserved Industrial USA Headquarters McKinney Texas 75070 USA Tel 1 800 558 5856 Outside U S 1 469 293 4201 Asia Pacific Shanghai China 201206 Tel 86 21 58...

Отзывы: